Passage Data · Cited limits by place · Use it from your AI
2,388 cited rows from 24 instruments, Florida's own first. Not covered: a permit's own limits, or rules outside the 70 instruments we hold for Florida (US-FL) and United States. Everything held for Florida
Florida: surface water 6, groundwater 4, soil 2 · United States: drinking water 5, surface water 5, effluent 2,360, soil 6
| Value | Applies when | Cite |
|---|---|---|
| 2.9 µg/L | receiving water: marine marine surface water (Table I, Marine Surface Water Criteria column) Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified. | Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Marine Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 139)row 139: Copper | 1000 | | 2.9 | 10000 | -Gastrointestinal | 7440-50-8 | | Secondary Standard | 62-302 | 62-302 | | Organoleptic & GI irritant | f, g | g |
| Value | Applies when | Cite |
|---|---|---|
| Cu ≤ e(0.8545[lnH]- 1.702) µg/L | receiving water: freshwater Class I, potable water supplies (waters listed by name in 62-302.400, F.A.C.) | F.A.C. 62-302.530(23) · p. 34 |
| ≤ 3.7 µg/L | receiving water: marine Class II, shellfish propagation or harvesting (waters listed by name in 62-302.400, F.A.C.) | as above |
| Cu ≤ e(0.8545[lnH]- 1.702) µg/L | receiving water: freshwater Class III and Class III-Limited, predominantly fresh waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III) | as above |
| ≤ 3.7 µg/L | receiving water: marine Class III and Class III-Limited, predominantly marine waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III) | as above |
| < 500 µg/L | receiving water: freshwater Class IV, agricultural water supplies (waters listed by name in 62-302.400, F.A.C.) | as above |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Copper | 1000 µg/L | groundwater (Table I, Groundwater Criteria column) | Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 139)row 139: Copper | 1000 | | 2.9 | 10000 | -Gastrointestinal | 7440-50-8 | | Secondary Standard | 62-302 | 62-302 | | Organoleptic & GI irritant | f, g | g |
| Copper | 10000 µg/L | groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column) | Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 139)row 139: Copper | 1000 | | 2.9 | 10000 | -Gastrointestinal | 7440-50-8 | | Secondary Standard | 62-302 | 62-302 | | Organoleptic & GI irritant | f, g | g |
| Copper cyanide | 35 µg/L | groundwater (Table I, Groundwater Criteria column) | Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 140)row 140: Copper cyanide | 35 | | | 350 | -Kidney | 544-92-3 | | Minimum Criteria | NA | NA | | Systemic Toxicant |
| Copper cyanide | 350 µg/L | groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column) | Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 140)row 140: Copper cyanide | 35 | | | 350 | -Kidney | 544-92-3 | | Minimum Criteria | NA | NA | | Systemic Toxicant |
| Value | Applies when | Cite |
|---|---|---|
| 150 mg/kg | residential direct exposure (Table II, Direct Exposure - Residential column) ** Direct exposure value based on acute toxicity considerations. This criterion is applicable in scenarios where children might be exposed to soils (e.g. residences, schools, playgrounds) | Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Residential (DEP spreadsheet, sheet TTable2, row 130)row 130: Copper | -Gastrointestinal | 7440-50-8 | 150** | 89000 | *** | NA | *** | *** |
| 89000 mg/kg | industrial direct exposure (Table II, Direct Exposure - Industrial column) | Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Industrial (DEP spreadsheet, sheet TTable2, row 130)row 130: Copper | -Gastrointestinal | 7440-50-8 | 150** | 89000 | *** | NA | *** | *** |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Kind | Applies when | Cite |
|---|---|---|---|
| 1.3 mg/l | guideline | 40 CFR 141.2: Maximum contaminant level goals are nonenforceable health goals. | 141.51 |
| 1.3 mg/L | threshold | 40 CFR 141.2: Action level, for the purpose of subpart I of this part only, means the concentrations of lead or copper in water as specified in § 141.80(c) which determines requirements under subpart I of this part. 90th percentile concentration of copper as specified in paragraph (c)(3) of this section (3) Community water systems and non-transient non-community water systems must comply with the requirements of this subpart no later than November 1, 2027 | 141.80(c)(2)(2) The copper action level is exceeded if the 90th percentile concentration of copper as specified in paragraph (c)(3) of this section is greater than 1.3 mg/L. |
| Value | Applies when | Cite |
|---|---|---|
| 1.0 mg/l | 40 CFR 143.1: The regulations in this subpart are not Federally enforceable but are intended as guidelines for the States. | 143.3 |
| Parameter | Value | Cite |
|---|---|---|
| Copper | 800 µg/L | source |
| ~Copper Cyanide | 100 µg/L | as above |
| Value | Applies when | Cite |
|---|---|---|
| 4.8 µg/L | receiving water: marine Saltwater CMC (acute): criterion maximum concentration, acute | National Recommended Aquatic Life Criteria tableCopper (P) 7440508 — — 4.8 3.1 2007 |
| 3.1 µg/L | receiving water: marine Saltwater CCC (chronic): criterion continuous concentration, chronic | as above |
| Freshwater criteria calculated using the Biotic Ligand Model. | receiving water: freshwater Freshwater CMC (acute): Freshwater criteria calculated using the Biotic Ligand Model; never evaluated here | as above |
| Freshwater criteria calculated using the Biotic Ligand Model. | receiving water: freshwater Freshwater CCC (chronic): Freshwater criteria calculated using the Biotic Ligand Model; never evaluated here | as above |
| Value | Applies when | Cite |
|---|---|---|
| 1,300 µg/L | EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use receiving water: freshwater consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns) | National Recommended Water Quality Criteria — Human Health Criteria TableCopper (P) 7440508 1,300 — 1992 |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Cu | 4.5 mg/L | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.14 (PSES)Cu 4.5 2.7 |
| Cu | 2.7 mg/L | — | as above | as above |
| Cu | 176 mg/sq m-Operation | daily maximum | the discharge is of the Subpart A—Electroplating of Common Metals Subcategory (d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes: table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation) | 40 CFR 413.14 (PSES)Cu 176 105 |
| Cu | 105 mg/sq m-Operation | — | as above | as above |
| Cu | 4.5 mg/L | daily maximum | the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory (c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.24 (PSES)Cu 4.5 2.7 |
All 28 rows from 40 CFR Part 413 — Electroplating point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Total Copper | 3,380 µg/L | daily maximum | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (BAT)Total Copper 3,380 1,450 |
| Total Copper | 3,380 µg/L | daily maximum | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (NSPS)Total Copper 3,380 1,450 |
| Total Copper | 1,450 µg/L | monthly average | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (BAT)Total Copper 3,380 1,450 |
| Total Copper | 1,450 µg/L | monthly average | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (NSPS)Total Copper 3,380 1,450 |
| Total Copper | 3,380 µg/L | daily maximum | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (BAT)Total Copper 3,380 1,450 |
| Total Copper | 3,380 µg/L | daily maximum | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (NSPS)Total Copper 3,380 1,450 |
| Total Copper | 1,450 µg/L | monthly average | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (BAT)Total Copper 3,380 1,450 |
| Total Copper | 1,450 µg/L | monthly average | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (NSPS)Total Copper 3,380 1,450 |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Copper (T) | 0.018 Kg/kkg (or pounds per/1,000 lb) of product | daily maximum | discharge to surface water existing sources (BPT) table: Subpart F—Chlor-Alkali Diaphragm Cells | 40 CFR 415.62 (BPT)Copper (T) 0.018 0.0070 |
| Copper (T) | 0.0070 Kg/kkg (or pounds per/1,000 lb) of product | monthly average | as above | as above |
| Copper (T) | 0.012 Kg/kkg (or pounds per 1,000 lb) of product | daily maximum | discharge to surface water existing sources (BAT) table: Subpart F—Chlor-Alkali-Diaphragm Cells | 40 CFR 415.63 (BAT)Copper (T) 0.012 0.0049 |
| Copper (T) | 0.0049 Kg/kkg (or pounds per 1,000 lb) of product | monthly average | as above | as above |
| Copper (T) | 2.1 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Subpart F—Chlor-Alkali-Diaphragm Cells | 40 CFR 415.64 (PSES)Copper (T) 2.1 0.80 |
All 30 rows from 40 CFR Part 415 — Inorganic chemicals manufacturing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.003 kilograms per 1,000 kg of product | monthly average | the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory existing sources (BPT) (d) The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart and which processes residues by wet methods, after application of the best practical control technology currently available: table: Effluent Limitations | 40 CFR 421.32 (BPT)Copper 0.003 |
| 0.0017 (Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product) | daily maximum | the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory existing sources (BPT) table: Effluent Limitations | 40 CFR 421.52 (BPT)Copper 0.0017 0.0008 |
| 0.0008 (Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product) | monthly average | as above | as above |
| .638 mg/kg (pounds per million pounds) of copper cast | daily maximum | the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory existing sources (BAT) (a) Subpart E—Casting Contact Cooling. table: BAT Effluent Limitations | 40 CFR 421.53 (BAT)Copper .638 .304 |
| .304 mg/kg (pounds per million pounds) of copper cast | monthly average | as above | as above |
All 725 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Copper, total | 1.0 mg/L | daily maximum | existing sources (BPT) (5) The quantity of pollutants discharged in metal cleaning wastes shall not exceed the quantity determined by multiplying the flow of metal cleaning wastes times the concentration listed in the following table: | 40 CFR 423.12 (BPT)Copper, total 1.0 1.0 |
| Copper, total | 1.0 mg/L | monthly average | as above | as above |
| Copper, total | 1.0 mg/L | daily maximum | existing sources (BAT) (e) The quantity of pollutants discharged in chemical metal cleaning wastes shall not exceed the quantity determined by multiplying the flow of chemical metal cleaning wastes times the concentration listed in the following table: | 40 CFR 423.13 (BAT)Copper, total 1.0 1.0 |
| Copper, total | 1.0 mg/L | monthly average | as above | as above |
| Copper, total | 1.0 mg/L | daily maximum | new sources (NSPS) (4) Chemical metal cleaning wastes. The quantity of pollutants discharged in chemical metal cleaning wastes shall not exceed the quantity determined by multiplying the flow of chemical metal cleaning wastes times the concentration listed in the following table: | 40 CFR 423.15 (NSPS)Copper, total 1.0 1.0 |
All 11 rows from 40 CFR Part 423 — Steam electric power generating point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 5 mg/L | daily maximum | the discharge is of the Subpart G—Wood Preserving Steam Subcategory table: Subpart G [PSES Effluent Limitations] | 40 CFR 429.85 (PSES)Copper 5 |
| .62 | daily maximum | the discharge is of the Subpart G—Wood Preserving Steam Subcategory table: [Grams per cubic meter of production] | 40 CFR 429.85 (PSES)Copper .62 |
| 5 mg/L | daily maximum | the discharge is of the Subpart H—Wood Preserving—Boulton Subcategory table: Subpart H [PSES Effluent Limitations] | 40 CFR 429.95 (PSES)Copper 5 |
| .62 | daily maximum | the discharge is of the Subpart H—Wood Preserving—Boulton Subcategory table: Subpart H [PSES Effluent Limitations; grams per cu m of production] | 40 CFR 429.95 (PSES)Copper .62 |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Copper (T) | 3.38 mg/L | daily maximum | discharge to surface water existing sources (BPT) table: BPT Effluent Limitations | 40 CFR 433.13 (BPT)Copper (T) 3.38 2.07 |
| Copper (T) | 2.07 mg/L | monthly average | as above | as above |
| Copper (T) | 3.38 mg/L | daily maximum | discharge to surface water existing sources (BAT) table: BAT Effluent Limitations | 40 CFR 433.14 (BAT)Copper (T) 3.38 2.07 |
| Copper (T) | 2.07 mg/L | monthly average | as above | as above |
| Copper (T) | 3.38 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: PSES for All Plants Except Job Shops and Independent Printed Circuit Board Manufacturers | 40 CFR 433.15 (PSES)Copper (T) 3.38 2.07 |
All 10 rows from 40 CFR Part 433 — Metal finishing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 4.14 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.11 (BPT)Copper 4.14 1.06 |
| 1.06 mg/L | monthly average | as above | as above |
| 0.659 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery new sources (NSPS) table: Performance Standards | 40 CFR 437.14 (NSPS)Copper 0.659 0.216 |
| 0.216 mg/L | monthly average | as above | as above |
| 0.500 mg/L | daily maximum | the discharge is of the Subpart B—Oils Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.21 (BPT)Copper 0.500 0.242 |
All 42 rows from 40 CFR Part 437 — The centralized waste treatment point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Cu | .3 mg/L | daily maximum | (a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of tungsten bearing ores per year shall not exceed: | 40 CFR 440.62 (BPT)Cu .3 .15 |
| Cu | .15 mg/L | monthly average | as above | as above |
| Cu | .30 mg/L | daily maximum | (c) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of tungsten ores per year by purely physical methods including ore crushing, washing, jigging, heavy media separation, and magnetic and electrostatic separation shall not exceed: | 40 CFR 440.62 (BPT)Cu .30 .15 |
| Cu | .15 mg/L | monthly average | as above | as above |
| Cu | .30 mg/L | daily maximum | (d) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of tungsten ores per year by froth flotation methods shall not exceed: | as above |
All 46 rows from 40 CFR Part 440 — Ore mining and dressing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.84 mg/L | daily maximum | discharge to surface water the discharge is of the Subpart A—Tank Trucks and Intermodal Tank Containers Transporting Chemical and Petroleum Cargos existing sources (BPT) (a) Effluent Limitations | 40 CFR 442.11 (BPT)Copper 0.84 |
| 0.84 mg/L | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart A—Tank Trucks and Intermodal Tank Containers Transporting Chemical and Petroleum Cargos existing sources (PSES) table: Table—Pretreatment Standards | 40 CFR 442.15 (PSES)Copper 0.84 |
| 0.84 mg/L | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart A—Tank Trucks and Intermodal Tank Containers Transporting Chemical and Petroleum Cargos new sources (PSNS) table: Table—Pretreatment Standards | 40 CFR 442.16 (PSNS)Copper 0.84 |
| 0.10 mg/L | daily maximum | discharge to surface water the discharge is of the Subpart C—Tank Barges and Ocean/Sea Tankers Transporting Chemical and Petroleum Cargos existing sources (BPT) table: Table—Effluent Limitations | 40 CFR 442.31 (BPT)Copper 0.10 |
| 0.10 mg/L | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart C—Tank Barges and Ocean/Sea Tankers Transporting Chemical and Petroleum Cargos existing sources (PSES) table: Table—Pretreatment Standards | 40 CFR 442.35 (PSES)Copper 0.10 |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 23 µg/L | daily maximum | discharge to surface water existing sources (BPT) table: Effluent Limitations 1 | 40 CFR 444.13 (BPT)Copper 23 14 |
| 14 µg/L | monthly average | as above | as above |
| 23 µg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Pretreatment Standards 1 | 40 CFR 444.16 (PSES)Copper 23 14 |
| 14 µg/L | monthly average | as above | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.86 mg/kg of lead used | daily maximum | (1) Subpart C—Closed Formation—Double Fill, or Fill and Dump. | 40 CFR 461.31 (BPT)Copper 0.86 0.45 |
| 0.45 mg/kg of lead used | monthly average | as above | as above |
| 20.99 mg/kg of lead used | daily maximum | (2) Subpart C—Open Formation—Dehydrated. | 40 CFR 461.31 (BPT)Copper 20.99 11.05 |
| 11.05 mg/kg of lead used | monthly average | as above | as above |
| 0.10 mg/kg of lead used | daily maximum | (3) Subpart C—Open Formation—Wet. | 40 CFR 461.31 (BPT)Copper 0.10 0.05 |
All 94 rows from 40 CFR Part 461 — Battery manufacturing point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Copper (T) | 0.0771 kg/1,000 kkg (pounds per million pounds) of metal poured | daily maximum | table: BPT Effluent Limitations | 40 CFR 464.12 (BPT)Copper (T) 0.0771 0.0421 |
| Copper (T) | 0.0421 kg/1,000 kkg (pounds per million pounds) of metal poured | monthly average | as above | as above |
| Copper (T) | 0.77 mg/L | daily maximum | 40 CFR 464.12 (BPT)Copper (T) 0.77 0.42 0.017 | |
| Copper (T) | 0.42 mg/L | monthly average | as above | |
| Copper (T) | 0.017 kg/1,000 kkg (pounds per million pounds) of metal poured | annual average | as above |
All 587 rows from 40 CFR Part 464 — Metal molding and casting point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 4.96 mg/m (pounds per 1 million ft ) of area processed | daily maximum | existing sources (BPT) | 40 CFR 465.21 (BPT)Copper 4.96 (1.02) 2.61 (0.54) |
| 2.61 mg/m (pounds per 1 million ft ) of area processed | monthly average | as above | as above |
| 1.71 mg/m (pounds per 1 million ft ) of area processed | daily maximum | existing sources (BAT) | 40 CFR 465.22 (BAT)Copper 1.71 (0.35) 0.90 (0.19) |
| 0.90 mg/m (pounds per 1 million ft ) of area processed | monthly average | as above | as above |
| 0.44 mg/m (pounds per 1 million ft ) of area processed | daily maximum | new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section which may be discharged by a new source subject to the provisions of this subpart: | 40 CFR 465.23 (NSPS)Copper 0.44 (0.090) 0.21 (0.043) |
All 10 rows from 40 CFR Part 465 — Coil coating point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.195 mg/off-kg of copper or copper alloy hot rolled | daily maximum | (a) Subpart A—Hot Rolling Spent Lubricant BPT Effluent Limitations. | 40 CFR 468.11 (BPT)Copper 0.195 0.103 |
| 0.103 mg/off-kg of copper or copper alloy hot rolled | monthly average | as above | as above |
| 0.720 mg/off-kg of copper or copper alloy cold rolled | daily maximum | (b) Subpart A—Cold Rolling Spent Lubricant BPT Effluent Limitations. | 40 CFR 468.11 (BPT)Copper 0.720 0.379 |
| 0.379 mg/off-kg of copper or copper alloy cold rolled | monthly average | as above | as above |
| 0.161 mg/off-kg of copper or copper alloy drawn | daily maximum | (c) Subpart A—Drawing Spent Lubricant BPT Effluent Limitations. | 40 CFR 468.11 (BPT)Copper 0.161 0.085 |
All 170 rows from 40 CFR Part 468 — Copper forming point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.147 mg/off-kg (pounds per million off-pounds) of precious metals rolled with emulsions | daily maximum | (b) Rolling spent emulsions. | 40 CFR 471.41 (BPT)Copper 0.147 0.077 |
| 0.077 mg/off-kg (pounds per million off-pounds) of precious metals rolled with emulsions | monthly average | as above | as above |
| 0.091 mg/off-kg (pounds per million off-pounds) of precious metals drawn with emulsions | daily maximum | (d) Drawing spent emulsions. | 40 CFR 471.41 (BPT)Copper 0.091 0.048 |
| 0.048 mg/off-kg (pounds per million off-pounds) of precious metals drawn with emulsions | monthly average | as above | as above |
| 0.006 mg/off-kg (pounds per million off-pounds) of precious metals drawn with soap solutions | daily maximum | (e) Drawing spent soap solutions. | 40 CFR 471.41 (BPT)Copper 0.006 0.003 |
| Parameter | Value | Kind | Applies when | Cite |
|---|---|---|---|---|
| Copper | 3100 mg/kg | guideline | Resident Soil (mg/kg) | source |
| Copper | 47000 mg/kg | guideline | Industrial Soil (mg/kg) | as above |
| Copper | 28 mg/kg | guideline | Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| Copper | 46 mg/kg | reference value (not a limit) | Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| ~Copper Cyanide | 390 mg/kg | guideline | Resident Soil (mg/kg) | as above |
| ~Copper Cyanide | 5800 mg/kg | guideline | Industrial Soil (mg/kg) | as above |
This page shows 109 of 2,388 rows: every instrument, each with its first 5 rows or all of them. All 2,388 as JSON, 200 a page.
6 NPDES permits in Florida went over a copper limit in their last 12 months of reports: the list as JSON.
70 instruments we hold for Florida (US-FL) and United States, for 19 names matching “copper” (each in the JSON). 24 have a row, in the tables above; 46 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the copper limits in Florida? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=copper&place=US-FL; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.