| Value | Applies when | Cite |
|---|---|---|
| 0.5*e(1.72*ln(hardness)-6.52) µg/L | segments classified for aquatic life hardness-dependent: the cell's equation of the hardness (mg/L CaCO3, at most 400; Table III footnote 3); Table IV works it at set hardness | 5 CCR 1002-31 31.16 Table III · p. 59 |
| e(1.72*ln(hardness)-9.06) Trout(19) = e(1.72*ln(hardness)-10.51) µg/L | as above | as above |
| 100(F) (acute) µg/L | segments classified for domestic water supply | as above |
| 0.19 µg/L | segments classified for aquatic life mean hardness 25 mg/L calcium carbonate (Table IV; illustrative values of the Table III equations, footnote 1) | 5 CCR 1002-31 31.16 Table IV · p. 63 |
| 0.62 µg/L | segments classified for aquatic life mean hardness 50 mg/L calcium carbonate (Table IV; illustrative values of the Table III equations, footnote 1) | as above |
| 1.2 µg/L | segments classified for aquatic life mean hardness 75 mg/L calcium carbonate (Table IV; illustrative values of the Table III equations, footnote 1) | as above |
| 2.0 µg/L | segments classified for aquatic life mean hardness 100 mg/L calcium carbonate (Table IV; illustrative values of the Table III equations, footnote 1) | as above |
| 4.1 µg/L | segments classified for aquatic life mean hardness 150 mg/L calcium carbonate (Table IV; illustrative values of the Table III equations, footnote 1) | as above |
| 6.7 µg/L | segments classified for aquatic life mean hardness 200 mg/L calcium carbonate (Table IV; illustrative values of the Table III equations, footnote 1) | as above |
| 9.8 µg/L | segments classified for aquatic life mean hardness 250 mg/L calcium carbonate (Table IV; illustrative values of the Table III equations, footnote 1) | as above |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Applies when | Cite |
|---|---|---|
| 0.1 mg/l | 40 CFR 143.1: The regulations in this subpart are not Federally enforceable but are intended as guidelines for the States. | 143.3 |
| Parameter | Value | Cite |
|---|---|---|
| Silver | 94 µg/L | source |
| ~Potassium Silver Cyanide | 82 µg/L | as above |
| ~Silver Cyanide | 1800 µg/L | as above |
| Value | Applies when | Cite |
|---|---|---|
| 3.2 µg/L | receiving water: freshwater Freshwater CMC (acute): criterion maximum concentration, acute | National Recommended Aquatic Life Criteria tableSilver (P) 7440224 3.2 — 1.9 — 1980 |
| 1.9 µg/L | receiving water: marine Saltwater CMC (acute): criterion maximum concentration, acute | as above |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Ag | 1.2 mg/L | daily maximum | (c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | 40 CFR 413.24 (PSES)Ag 1.2 0.7 |
| Ag | 0.7 mg/L | — | as above | as above |
| Ag | 47 mg/sq m-Operation | daily maximum | (d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes: table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation) | 40 CFR 413.24 (PSES)Ag 47 29 |
| Ag | 29 mg/sq m-Operation | — | as above | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.0090 Kg/kkg (or pounds per 1,000 lb) of product | daily maximum | discharge to surface water existing sources (BPT) | 40 CFR 415.532 (BPT)Silver 0.0090 0.0030 |
| 0.0030 Kg/kkg (or pounds per 1,000 lb) of product | monthly average | as above | as above |
| 1.0 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) | 40 CFR 415.534 (PSES)Silver 1.0 0.5 |
| 0.5 mg/L | monthly average | as above | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.533 mg/troy ounce of gold and silver smelted | daily maximum | (a) Smelter wet air pollution control. | 40 CFR 421.252 (BPT)Silver 0.533 0.221 |
| 0.221 mg/troy ounce of gold and silver smelted | monthly average | as above | as above |
| 0.164 mg/troy ounce of silver reduced in solution | daily maximum | (b) Silver chloride reduction spent solution. | 40 CFR 421.252 (BPT)Silver 0.164 0.068 |
| 0.068 mg/troy ounce of silver reduced in solution | monthly average | as above | as above |
| 81.180 mg/troy ounce of gold refined electrolytically | daily maximum | (c) Electrolytic cells wet air pollution control. | 40 CFR 421.252 (BPT)Silver 81.180 33.660 |
| 33.660 mg/troy ounce of gold refined electrolytically | monthly average | as above | as above |
| 0.021 mg/troy ounce of silver in electrolyte produced | daily maximum | (d) Electrolyte preparation wet air pollution control. | 40 CFR 421.252 (BPT)Silver 0.021 0.009 |
| 0.009 mg/troy ounce of silver in electrolyte produced | monthly average | as above | as above |
| 76.340 mg/kg (pounds per million pounds) of mercury condensed | daily maximum | (e) Calciner wet air pollution control. | 40 CFR 421.252 (BPT)Silver 76.340 31.650 |
| 31.650 mg/kg (pounds per million pounds) of mercury condensed | monthly average | as above | as above |
All 72 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Silver (T) | 0.43 mg/L | daily maximum | discharge to surface water existing sources (BPT) table: BPT Effluent Limitations | 40 CFR 433.13 (BPT)Silver (T) 0.43 0.24 |
| Silver (T) | 0.24 mg/L | monthly average | as above | as above |
| Silver (T) | 0.43 mg/L | daily maximum | discharge to surface water existing sources (BAT) table: BAT Effluent Limitations | 40 CFR 433.14 (BAT)Silver (T) 0.43 0.24 |
| Silver (T) | 0.24 mg/L | monthly average | as above | as above |
| Silver (T) | 0.43 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: PSES for All Plants Except Job Shops and Independent Printed Circuit Board Manufacturers | 40 CFR 433.15 (PSES)Silver (T) 0.43 0.24 |
| Silver (T) | 0.24 mg/L | monthly average | as above | as above |
| Silver (T) | 0.43 mg/L | daily maximum | discharge to surface water new sources (NSPS) (a) Any new source subject to this subpart must achieve the following performance standards: table: NSPS | 40 CFR 433.16 (NSPS)Silver (T) 0.43 0.24 |
| Silver (T) | 0.24 mg/L | monthly average | as above | as above |
| Silver (T) | 0.43 mg/L | daily maximum | discharge to a sewer (pretreatment) new sources (PSNS) table: PSNS | 40 CFR 433.17 (PSNS)Silver (T) 0.43 0.24 |
| Silver (T) | 0.24 mg/L | monthly average | as above | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.120 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.11 (BPT)Silver 0.120 0.0351 |
| 0.0351 mg/L | monthly average | as above | as above |
| 0.0318 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery new sources (NSPS) table: Performance Standards | 40 CFR 437.14 (NSPS)Silver 0.0318 0.0122 |
| 0.0122 mg/L | monthly average | as above | as above |
| 0.120 mg/L | daily maximum | the discharge is of the Subpart D—Multiple Wastestreams existing sources (BPT) (b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT: table: BPT Limitations | 40 CFR 437.42 (BPT)Silver 0.120 0.0351 |
| 0.0351 mg/L | monthly average | as above | as above |
| 0.120 mg/L | daily maximum | the discharge is of the Subpart D—Multiple Wastestreams existing sources (BPT) (c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT: table: BPT Limitations | as above |
| 0.0351 mg/L | monthly average | as above | as above |
| 0.120 mg/L | daily maximum | the discharge is of the Subpart D—Multiple Wastestreams existing sources (BPT) (d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT: table: BPT Limitations | as above |
| 0.0351 mg/L | monthly average | as above | as above |
All 28 rows from 40 CFR Part 437 — The centralized waste treatment point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 13 µg/L | daily maximum | discharge to surface water existing sources (BPT) table: Effluent Limitations 1 | 40 CFR 444.13 (BPT)Silver 13 8 |
| 8 µg/L | monthly average | as above | as above |
| 13 µg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Pretreatment Standards 1 | 40 CFR 444.16 (PSES)Silver 13 8 |
| 8 µg/L | monthly average | as above | as above |
| Parameter | Value | Statistic | Cite |
|---|---|---|---|
| Ag | 0.14 kilograms per 1,000 m of product | daily maximum | 40 CFR 459.12 (BPT)Ag 0.14 0.07 |
| Ag | 0.07 kilograms per 1,000 m of product | monthly average | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 8.69 mg/kg of silver powder produced | daily maximum | discharge to surface water existing sources (BPT) (8) Subpart A—Silver Powder Production. table: BPT Effluent Limitations | 40 CFR 461.11 (BPT)Silver 8.69 3.61 |
| 3.61 mg/kg of silver powder produced | monthly average | as above | as above |
| 1.32 mg/kg of silver powder produced | daily maximum | discharge to surface water existing sources (BAT) (7) Subpart A—Silver Powder Production. table: BAT Effluent Limitations | 40 CFR 461.12 (BAT)Silver 1.32 0.55 |
| 0.55 mg/kg of silver powder produced | monthly average | as above | as above |
| 0.93 mg/kg of silver powder produced | daily maximum | discharge to surface water new sources (NSPS) (7) Subpart A—Silver Powder Production—NSPS. | 40 CFR 461.13 (NSPS)Silver 0.93 0.39 |
| 0.39 mg/kg of silver powder produced | monthly average | as above | as above |
| 1.32 mg/kg of silver powder produced | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) (7) Subpart A—Silver Powder Production—PSES. | 40 CFR 461.14 (PSES)Silver 1.32 0.55 |
| 0.55 mg/kg of silver powder produced | monthly average | as above | as above |
| 0.93 mg/kg of silver powder produced | daily maximum | discharge to a sewer (pretreatment) new sources (PSNS) (7) Subpart A—Silver Powder Production—PSNS. | 40 CFR 461.15 (PSNS)Silver 0.93 0.39 |
| 0.39 mg/kg of silver powder produced | monthly average | as above | as above |
All 146 rows from 40 CFR Part 461 — Battery manufacturing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.032 mg/off-kg (pounds per million off-pounds) of precious metals rolled with emulsions | daily maximum | (b) Rolling spent emulsions. | 40 CFR 471.41 (BPT)Silver 0.032 0.013 |
| 0.013 mg/off-kg (pounds per million off-pounds) of precious metals rolled with emulsions | monthly average | as above | as above |
| 0.020 mg/off-kg (pounds per million off-pounds) of precious metals drawn with emulsions | daily maximum | (d) Drawing spent emulsions. | 40 CFR 471.41 (BPT)Silver 0.020 0.008 |
| 0.008 mg/off-kg (pounds per million off-pounds) of precious metals drawn with emulsions | monthly average | as above | as above |
| 0.001 mg/off-kg (pounds per million off-pounds) of precious metals drawn with soap solutions | daily maximum | (e) Drawing spent soap solutions. | 40 CFR 471.41 (BPT)Silver 0.001 0.0006 |
| 0.0006 mg/off-kg (pounds per million off-pounds) of precious metals drawn with soap solutions | monthly average | as above | as above |
| 2.70 mg/off-kg (pounds per million off-pounds) of precious metals powder wet atomized | daily maximum | (f) Metal powder production wet atomization wastewater. | 40 CFR 471.41 (BPT)Silver 2.70 1.14 |
| 1.14 mg/off-kg (pounds per million off-pounds) of precious metals powder wet atomized | monthly average | as above | as above |
| 1.71 mg/off-kg (pounds per million off-pounds) of extruded precious metals heat treated | daily maximum | (g) Heat treatment contact cooling water. | 40 CFR 471.41 (BPT)Silver 1.71 0.709 |
| 0.709 mg/off-kg (pounds per million off-pounds) of extruded precious metals heat treated | monthly average | as above | as above |
| Value | Applies when | Cite |
|---|---|---|
| 5.0 mg/L | (a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section. | 40 CFR 261.24, Table 1D011 Silver 7440-22-4 5.0 |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.14 mg/L TCLP | instantaneous | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standardSilver 7440-22-4 0.43 0.14 mg/l TCLP |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Silver | 390 mg/kg | Resident Soil (mg/kg) | source |
| Silver | 5800 mg/kg | Industrial Soil (mg/kg) | as above |
| Silver | 0.8 mg/kg | Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| ~Potassium Silver Cyanide | 390 mg/kg | Resident Soil (mg/kg) | as above |
| ~Potassium Silver Cyanide | 5800 mg/kg | Industrial Soil (mg/kg) | as above |
| ~Silver Cyanide | 7800 mg/kg | Resident Soil (mg/kg) | as above |
| ~Silver Cyanide | 120000 mg/kg | Industrial Soil (mg/kg) | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.43 mg/L | composite sample | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standardSilver 7440-22-4 0.43 0.14 mg/l TCLP |
This page shows 90 of 479 rows: every instrument, each with its first 10 rows or all of them. All 479 as JSON, 200 a page.
2 NPDES permits in Colorado went over a silver limit in their last 12 months of reports: the list as JSON.
69 instruments we hold for Colorado (US-CO) and United States, for 15 names matching “silver” (each in the JSON). 16 have a row, in the tables above; 53 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the silver limits in Colorado? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=silver&place=US-CO; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.