Passage Data · Cited limits by place · Use it from your AI
3,205 cited rows from 27 instruments, Arkansas's own first. Not covered: a permit's own limits, or rules outside the 69 instruments we hold for Arkansas (US-AR) and United States. Everything held for Arkansas
Arkansas: surface water 2 · United States: drinking water 7, surface water 6, effluent 3,169, leachate 2, soil 15, ambient air 2, air emission 1, product 1
| Parameter | Value | Cite |
|---|---|---|
| Lead (dissolved) | e[1.273(lnhardness)]-1.460 X (b) µg/L | 8 CAR § 21-508(d), Dissolved Metals · p. 33Lead e[ 1.273(lnhardness)]-1.460 (b) e[ 1.273(lnhardness)]-4.705 (b) |
| Lead (dissolved) | e[1.273(lnhardness)]-4.705 X (b) µg/L | as above |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Kind | Applies when | Cite |
|---|---|---|---|
| zero | guideline | 40 CFR 141.2: Maximum contaminant level goals are nonenforceable health goals. | 141.51 |
| 0.010 mg/L | threshold | 40 CFR 141.2: Action level, for the purpose of subpart I of this part only, means the concentrations of lead or copper in water as specified in § 141.80(c) which determines requirements under subpart I of this part. 90th percentile concentration of lead as specified in paragraph (c)(3) of this section (3) Community water systems and non-transient non-community water systems must comply with the requirements of this subpart no later than November 1, 2027 | 141.80(c)(1)(1) The lead action level is exceeded if the 90th percentile concentration of lead as specified in paragraph (c)(3) of this section is greater than 0.010 mg/L. |
| Parameter | Value | Cite |
|---|---|---|
| ~Lead and Compounds | 10 µg/L | source |
| ~Lead acetate | 0.37 µg/L | as above |
| ~Lead subacetate | 2.1 µg/L | as above |
| ~Lead Phosphate | 9.1 µg/L | as above |
| ~Tetraethyl Lead | 0.0013 µg/L | as above |
| Value | Applies when | Cite |
|---|---|---|
| 65 µg/L | receiving water: freshwater Freshwater CMC (acute): criterion maximum concentration, acute corresponds to a hardness of 100 mg/L as CaCO3 (the table's value; the criterion is a function of hardness) | National Recommended Aquatic Life Criteria tableLead (P) 7439921 65 2.5 210 8.1 1984 |
| exp{1.273 [ln(hardness)] + -1.460} × CF, CF = 1.46203-[( ln hardness)(0.145712)] µg/L | receiving water: freshwater Freshwater CMC (acute), computed at the receiving water's hardness (mg/L as CaCO3) by the printed equation; never evaluated here | Appendix B — Parameters for Calculating Freshwater Dissolved Metals Criteria That Are Hardness-DependentLead 1.273 -1.460 1.273 -4.705 1.46203-[( ln hardness)(0.145712)] 1.46203-[( ln hardness)(0.145712)] |
| 2.5 µg/L | receiving water: freshwater Freshwater CCC (chronic): criterion continuous concentration, chronic corresponds to a hardness of 100 mg/L as CaCO3 (the table's value; the criterion is a function of hardness) | National Recommended Aquatic Life Criteria tableLead (P) 7439921 65 2.5 210 8.1 1984 |
| exp{1.273 [ln(hardness)] + -4.705} × CF, CF = 1.46203-[( ln hardness)(0.145712)] µg/L | receiving water: freshwater Freshwater CCC (chronic), computed at the receiving water's hardness (mg/L as CaCO3) by the printed equation; never evaluated here | Appendix B — Parameters for Calculating Freshwater Dissolved Metals Criteria That Are Hardness-DependentLead 1.273 -1.460 1.273 -4.705 1.46203-[( ln hardness)(0.145712)] 1.46203-[( ln hardness)(0.145712)] |
| 210 µg/L | receiving water: marine Saltwater CMC (acute): criterion maximum concentration, acute | National Recommended Aquatic Life Criteria tableLead (P) 7439921 65 2.5 210 8.1 1984 |
| 8.1 µg/L | receiving water: marine Saltwater CCC (chronic): criterion continuous concentration, chronic | as above |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Pb | .6 mg/L | daily maximum | (b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l) | 40 CFR 413.14 (PSES)Pb .6 .4 |
| Pb | .4 mg/L | — | as above | as above |
| Pb | .6 mg/L | daily maximum | (c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply: table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l) | as above |
| Pb | .4 mg/L | — | as above | as above |
| Pb | 23 mg/sq m-Operation | daily maximum | (d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes: table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation) | 40 CFR 413.14 (PSES)Pb 23 16 |
All 56 rows from 40 CFR Part 413 — Electroplating point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Total Lead | 690 µg/L | daily maximum | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (BAT)Total Lead 690 320 |
| Total Lead | 690 µg/L | daily maximum | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (NSPS)Total Lead 690 320 |
| Total Lead | 320 µg/L | monthly average | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (BAT)Total Lead 690 320 |
| Total Lead | 320 µg/L | monthly average | the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (NSPS)Total Lead 690 320 |
| Total Lead | 690 µg/L | daily maximum | the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (BAT)Total Lead 690 320 |
All 10 rows from 40 CFR Part 414 — Organic chemicals, plastics, and synthetic fibers
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Lead (T) | 0.026 Kg/kkg (or pounds per/1,000 lb) of product | daily maximum | discharge to surface water existing sources (BPT) table: Subpart F—Chlor-Alkali Diaphragm Cells | 40 CFR 415.62 (BPT)Lead (T) 0.026 0.010 |
| Lead (T) | 0.010 Kg/kkg (or pounds per/1,000 lb) of product | monthly average | as above | as above |
| Lead (T) | 0.0059 Kg/kkg (or pounds per 1,000 lb) of product | daily maximum | discharge to surface water existing sources (BAT) table: Subpart F—Chlor-Alkali-Diaphragm Cells | 40 CFR 415.63 (BAT)Lead (T) 0.0059 0.0024 |
| Lead (T) | 0.0024 Kg/kkg (or pounds per 1,000 lb) of product | monthly average | as above | as above |
| Lead (T) | 2.9 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Subpart F—Chlor-Alkali-Diaphragm Cells | 40 CFR 415.64 (PSES)Lead (T) 2.9 1.1 |
All 24 rows from 40 CFR Part 415 — Inorganic chemicals manufacturing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.000451 Pounds per thousand lb of product | daily maximum | discharge to surface water existing sources (BAT) (a) Sintering operations with wet air pollution control system. The following table presents BAT limitations for sintering operations with wet air pollution control systems: table: Subpart B—Effluent Limitations (BAT) | 40 CFR 420.23 (BAT)Lead 0.000451 0.000150 |
| 0.000150 Pounds per thousand lb of product | monthly average | as above | as above |
| 0.000451 Pounds per thousand lb of product | daily maximum | discharge to surface water new sources (NSPS) (1) Sintering operations with wet air pollution control system. The following table presents NSPS for sintering operations with wet air pollution control systems: table: Subpart B—New Source Performance Standards (NSPS) | 40 CFR 420.24 (NSPS)Lead 0.000451 0.000150 |
| 0.000150 Pounds per thousand lb of product | monthly average | as above | as above |
| 0.000451 Pounds per thousand lb of product | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) (a) Sintering operations with wet air pollution control system. The following table presents PSES for sintering operations with wet air pollution control systems: table: Subpart B—Pretreatment Standards for Existing Sources (PSES) | 40 CFR 420.25 (PSES)Lead 0.000451 0.000150 |
All 246 rows from 40 CFR Part 420 — Iron and steel manufacturing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| .000 mg/kg (pound's per million pounds) of aluminum scrap dried | daily maximum | (a) Subpart C—Scrap Drying Wet Air Pollution Control. | 40 CFR 421.33 (BAT)Lead .000 .000 |
| .000 mg/kg (pound's per million pounds) of aluminum scrap dried | monthly average | as above | as above |
| .000 mg/kg (pound's per million pounds) of aluminum scrap screened and milled | daily maximum | (b) Subpart C—Scrap Screening and Milling. | as above |
| .000 mg/kg (pound's per million pounds) of aluminum scrap screened and milled | monthly average | as above | as above |
| 3.043 mg/kg (pound's per million pounds) of dross washed | daily maximum | (c) Subpart C—Dross Washing. | 40 CFR 421.33 (BAT)Lead 3.043 1.413 |
All 1,292 rows from 40 CFR Part 421 — Nonferrous metals manufacturing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 39.0 g/kkg of furnace pull | daily maximum | existing sources (BPT) | 40 CFR 426.112 (BPT)Lead 39.0 4.5 |
| 4.5 g/kkg of furnace pull | monthly average | as above | as above |
| 0.9 g/kkg of furnace pull | daily maximum | existing sources (BAT) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable. These limitations are applicable to the abrasive polishing and acid polishing waste water streams. | 40 CFR 426.113 (BAT)Lead 0.9 0.45 |
| 0.45 g/kkg of furnace pull | monthly average | as above | as above |
| 30.9 g/kkg of furnace pull | daily maximum | new sources (NSPS) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart (the fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the… | 40 CFR 426.115 (NSPS)Lead 30.9 0.45 |
All 10 rows from 40 CFR Part 426 — Glass manufacturing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.0017 kg/kkg of raw material | daily maximum | existing sources (BPT) (b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, and attributable to lead-sheathed hose production, which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available, in addition to the limitations set forth by § 428… | 40 CFR 428.52 (BPT)Lead 0.0017 0.0007 |
| 0.0007 kg/kkg of raw material | monthly average | as above | as above |
| 0.0017 kg/kkg of raw material | daily maximum | existing sources (BAT) (b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, and attributable to lead-sheathed hose production, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable, in addition to the limitations set forth by § 428.53(a): | 40 CFR 428.53 (BAT)Lead 0.0017 0.0007 |
| 0.0007 kg/kkg of raw material | monthly average | as above | as above |
| 0.0017 kg/kkg of raw material | daily maximum | new sources (NSPS) (b) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, and attributable to lead-sheathed hose production, which may be discharged by a new source subject to the provisions of this subpart, in addition to the limitations set forth by § 428.55(a): | 40 CFR 428.55 (NSPS)Lead 0.0017 0.0007 |
All 28 rows from 40 CFR Part 428 — Rubber manufacturing point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Lead (T) | 0.69 mg/L | daily maximum | discharge to surface water existing sources (BPT) table: BPT Effluent Limitations | 40 CFR 433.13 (BPT)Lead (T) 0.69 0.43 |
| Lead (T) | 0.43 mg/L | monthly average | as above | as above |
| Lead (T) | 0.69 mg/L | daily maximum | discharge to surface water existing sources (BAT) table: BAT Effluent Limitations | 40 CFR 433.14 (BAT)Lead (T) 0.69 0.43 |
| Lead (T) | 0.43 mg/L | monthly average | as above | as above |
| Lead (T) | 0.69 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: PSES for All Plants Except Job Shops and Independent Printed Circuit Board Manufacturers | 40 CFR 433.15 (PSES)Lead (T) 0.69 0.43 |
All 10 rows from 40 CFR Part 433 — Metal finishing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 1.32 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.11 (BPT)Lead 1.32 0.283 |
| 0.283 mg/L | monthly average | as above | as above |
| 1.32 mg/L | daily maximum | the discharge is of the Subpart A—Metals Treatment and Recovery new sources (NSPS) table: Performance Standards | 40 CFR 437.14 (NSPS)Lead 1.32 0.283 |
| 0.283 mg/L | monthly average | as above | as above |
| 0.350 mg/L | daily maximum | the discharge is of the Subpart B—Oils Treatment and Recovery existing sources (BPT) table: BPT Limitations | 40 CFR 437.21 (BPT)Lead 0.350 0.160 |
All 40 rows from 40 CFR Part 437 — The centralized waste treatment point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Pb | .6 mg/L | daily maximum | the discharge is of the Subpart F—Tungsten Ore Subcategory (a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of tungsten bearing ores per year shall not exceed: | 40 CFR 440.62 (BPT)Pb .6 .3 |
| Pb | .3 mg/L | monthly average | as above | as above |
| Pb | .6 mg/L | daily maximum | the discharge is of the Subpart G—Nickel Ore Subcategory (a) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of nickel bearing ores per year shall not exceed: | 40 CFR 440.72 (BPT)Pb .6 .3 |
| Pb | .3 mg/L | monthly average | as above | as above |
| Pb | .6 mg/L | daily maximum | the discharge is of the Subpart H—Vanadium Ore Subcategory (Mined Alone and Not as a Byproduct) (a) The concentration of pollutants discharged in mine drainage from mines producing 5,000 metric tons (5,512 short tons) or more of vanadium bearing ores per year shall not exceed: | 40 CFR 440.82 (BPT)Pb .6 .3 |
All 22 rows from 40 CFR Part 440 — Ore mining and dressing point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.14 mg/L | daily maximum | discharge to surface water existing sources (BPT) table: Table—Effluent Limitations | 40 CFR 442.31 (BPT)Lead 0.14 |
| 0.14 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Table—Pretreatment Standards | 40 CFR 442.35 (PSES)Lead 0.14 |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 57 µg/L | daily maximum | discharge to surface water existing sources (BPT) table: Effluent Limitations 1 | 40 CFR 444.13 (BPT)Lead 57 32 |
| 32 µg/L | monthly average | as above | as above |
| 57 µg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) table: Pretreatment Standards 1 | 40 CFR 444.16 (PSES)Lead 57 32 |
| 32 µg/L | monthly average | as above | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.19 mg/kg of lead used | daily maximum | (1) Subpart C—Closed Formation—Double Fill, or Fill and Dump. | 40 CFR 461.31 (BPT)Lead 0.19 0.090 |
| 0.090 mg/kg of lead used | monthly average | as above | as above |
| 4.64 mg/kg of lead used | daily maximum | (2) Subpart C—Open Formation—Dehydrated. | 40 CFR 461.31 (BPT)Lead 4.64 2.21 |
| 2.21 mg/kg of lead used | monthly average | as above | as above |
| 0.02 mg/kg of lead used | daily maximum | (3) Subpart C—Open Formation—Wet. | 40 CFR 461.31 (BPT)Lead 0.02 0.01 |
All 130 rows from 40 CFR Part 461 — Battery manufacturing point source category
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Lead (T) | 0.0791 kg/1,000 kkg (pounds per million pounds) of metal poured | daily maximum | table: BPT Effluent Limitations | 40 CFR 464.12 (BPT)Lead (T) 0.0791 0.039 |
| Lead (T) | 0.039 kg/1,000 kkg (pounds per million pounds) of metal poured | monthly average | as above | as above |
| Lead (T) | 0.79 mg/L | daily maximum | 40 CFR 464.12 (BPT)Lead (T) 0.79 0.39 0.022 | |
| Lead (T) | 0.39 mg/L | monthly average | as above | |
| Lead (T) | 0.022 kg/1,000 kkg (pounds per million pounds) of metal poured | annual average | as above |
All 587 rows from 40 CFR Part 464 — Metal molding and casting point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 6.01 mg/m² of area processed or coated | daily maximum | existing sources (BPT) table: Subpart A—BPT Effluent Limitations column: Metal preparation | 40 CFR 466.11 (BPT)Lead 6.01 1.21 5.21 1.06 |
| 1.21 mg/m² of area processed or coated | daily maximum | existing sources (BPT) table: Subpart A—BPT Effluent Limitations column: Coating operation | as above |
| 5.21 mg/m² of area processed or coated | monthly average | existing sources (BPT) table: Subpart A—BPT Effluent Limitations column: Metal preparation | as above |
| 1.06 mg/m² of area processed or coated | monthly average | existing sources (BPT) table: Subpart A—BPT Effluent Limitations column: Coating operation | as above |
| 6.01 mg/m² of area processed or coated | daily maximum | existing sources (BAT) table: Subpart A—BAT Effluent Limitations column: Metal preparation | 40 CFR 466.12 (BAT)Lead 6.01 0.19 5.21 0.16 |
All 64 rows from 40 CFR Part 466 — Porcelain enameling point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.015 mg/off-kg of copper or copper alloy hot rolled | daily maximum | (a) Subpart A—Hot Rolling Spent Lubricant BPT Effluent Limitations. | 40 CFR 468.11 (BPT)Lead 0.015 0.013 |
| 0.013 mg/off-kg of copper or copper alloy hot rolled | monthly average | as above | as above |
| 0.056 mg/off-kg of copper or copper alloy cold rolled | daily maximum | (b) Subpart A—Cold Rolling Spent Lubricant BPT Effluent Limitations. | 40 CFR 468.11 (BPT)Lead 0.056 0.049 |
| 0.049 mg/off-kg of copper or copper alloy cold rolled | monthly average | as above | as above |
| 0.012 mg/off-kg of copper or copper alloy drawn | daily maximum | (c) Subpart A—Drawing Spent Lubricant BPT Effluent Limitations. | 40 CFR 468.11 (BPT)Lead 0.012 0.011 |
All 170 rows from 40 CFR Part 468 — Copper forming point source category
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 1.12 mg/L | daily maximum | discharge to a sewer (pretreatment) existing sources (PSES) | 40 CFR 469.34 (PSES)Lead 1.12 0.41 |
| 0.41 mg/L | monthly average | as above | as above |
| 0.72 mg/L | daily maximum | discharge to surface water new sources (NSPS) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): | 40 CFR 469.35 (NSPS)Lead 0.72 0.27 |
| 0.27 mg/L | monthly average | as above | as above |
| 0.72 mg/L | daily maximum | discharge to a sewer (pretreatment) new sources (PSNS) | 40 CFR 469.36 (PSNS)Lead 0.72 0.27 |
| 0.27 mg/L | monthly average | as above | as above |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.010 mg/off-kg (pounds per million off-pounds) of lead-tin-bismuth rolled with emulsions | daily maximum | (a) Rolling spent emulsions. | 40 CFR 471.11 (BPT)Lead 0.010 0.005 |
| 0.005 mg/off-kg (pounds per million off-pounds) of lead-tin-bismuth rolled with emulsions | monthly average | as above | as above |
| 0.019 mg/off-kg (pounds per million off-pound) of lead-tin-bismuth rolled with soap solutions | daily maximum | (b) Rolling spent soap solutions. | 40 CFR 471.11 (BPT)Lead 0.019 0.009 |
| 0.009 mg/off-kg (pounds per million off-pound) of lead-tin-bismuth rolled with soap solutions | monthly average | as above | as above |
| 0.011 mg/off-kg (pounds per million off-pounds) of lead-tin-bismuth drawn with emulsions | daily maximum | (d) Drawing spent emulsions. | 40 CFR 471.11 (BPT)Lead 0.011 0.005 |
| Value | Applies when | Cite |
|---|---|---|
| 5.0 mg/L | (a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section. | 40 CFR 261.24, Table 1D008 Lead 7439-92-1 5.0 |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.75 mg/L TCLP | instantaneous | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standardLead 7439-92-1 0.69 0.75 mg/l TCLP |
| Parameter | Value | Kind | Applies when | Cite |
|---|---|---|---|---|
| ~Lead and Compounds | 200 mg/kg | guideline | Resident Soil (mg/kg) | source |
| ~Lead and Compounds | 800 mg/kg | guideline | Industrial Soil (mg/kg) | as above |
| ~Lead and Compounds (with other sources of lead present, see Guidance) | 100 mg/kg | guideline | Resident Soil (mg/kg) | as above |
| ~Lead and Compounds | 9 mg/kg | reference value (not a limit) | Protection of Groundwater SSLs: MCL-based SSL (mg/kg); SSL values are based on DAF=1 | as above |
| ~Lead acetate | 2.6 mg/kg | guideline | Resident Soil (mg/kg) | as above |
| Value | Cite |
|---|---|
| 0.15 µg/m³ | § 50.16 National primary and secondary ambient air quality standards for lead.(a) The national primary and secondary ambient air quality standards for lead (Pb) and its compounds are 0.15 micrograms per cubic meter, arithmetic mean concentration over a 3-month period, measured in the ambient air as Pb either by: |
| 0.15 µg/m³ | as above |
| Value | Cite |
|---|---|
| 0.6 tpy | 52.21(b)(23)(i)Lead: 0.6 tpy |
| Value | Statistic | Applies when | Cite |
|---|---|---|---|
| 0.69 mg/L | composite sample | (a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS. | 40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standardLead 7439-92-1 0.69 0.75 mg/l TCLP |
This page shows 113 of 3,205 rows: every instrument, each with its first 5 rows or all of them. All 3,205 as JSON, 200 a page.
1 NPDES permit in Arkansas went over a lead limit in their last 12 months of reports: the list as JSON.
69 instruments we hold for Arkansas (US-AR) and United States, for 26 names matching “lead” (each in the JSON). 27 have a row, in the tables above; 42 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the lead limits in Arkansas? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=lead&place=US-AR; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.