Passage Data · Cited limits by place · Use it from your AI
10 rows for lead in this instrument. Every instrument for lead in Alabama
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Total Lead | 690 µg/L | daily maximum | discharge to surface water the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (BAT)Total Lead 690 320 |
| Total Lead | 690 µg/L | daily maximum | discharge to surface water the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (NSPS)Total Lead 690 320 |
| Total Lead | 320 µg/L | monthly average | discharge to surface water the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (BAT)Total Lead 690 320 |
| Total Lead | 320 µg/L | monthly average | discharge to surface water the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin… | 40 CFR 414.91 (NSPS)Total Lead 690 320 |
| Total Lead | 690 µg/L | daily maximum | discharge to surface water the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (BAT)Total Lead 690 320 |
| Total Lead | 690 µg/L | daily maximum | discharge to surface water the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (NSPS)Total Lead 690 320 |
| Total Lead | 320 µg/L | monthly average | discharge to surface water the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment existing sources (BAT) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (BAT)Total Lead 690 320 |
| Total Lead | 320 µg/L | monthly average | discharge to surface water the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment new sources (NSPS) (b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st… | 40 CFR 414.101 (NSPS)Total Lead 690 320 |
| Total Lead | 690 µg/L | daily maximum | discharge to a sewer (pretreatment) the discharge is of the Subpart K—Indirect Discharge Point Sources new sources (PSNS) (b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined… | 40 CFR 414.111 (PSNS)Total Lead 690 320 |
| Total Lead | 320 µg/L | monthly average | as above | as above |
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.