| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Nichel e composti | 4 μg/l | annual average | receiving water: freshwater | Tab. 1/A n. 23, SQA-MA, acque superficiali interne · p. 10(23) Nichel e composti 7440-02-0 413 8,6 34 34 P |
| Nichel e composti | 8,6 μg/l | annual average | receiving water: marine | Tab. 1/A n. 23, SQA-MA, altre acque di superficie · p. 10(23) Nichel e composti 7440-02-0 413 8,6 34 34 P |
| Nichel e composti | 34 μg/l | instantaneous | receiving water: freshwater | Tab. 1/A n. 23, SQA-CMA, acque superficiali interne · p. 10(23) Nichel e composti 7440-02-0 413 8,6 34 34 P |
| Nichel e composti | 34 μg/l | instantaneous | receiving water: marine | Tab. 1/A n. 23, SQA-CMA, altre acque di superficie · p. 10(23) Nichel e composti 7440-02-0 413 8,6 34 34 P |
| Parameter | Value | Cite |
|---|---|---|
| Nichel | 20 µg/l | source |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Nichel | ≤ 2 mg/L | discharge to surface water | acque superficiali · p. 226 |
| Nichel | ≤ 4 mg/L | discharge to a sewer (pretreatment) (*) I limiti per lo scarico in rete fognaria sono obbligatori in assenza di limiti stabiliti dall'autorità competente o in mancanza di un impianto finale di trattamento in grado di rispettare i limiti di emissione dello scarico finale. | rete fognaria · p. 226 |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Nichel | 0,2 mg/L | scarichi sul suolo (art. 103, comma 1, lettera c)): Nei casi previsti dall'articolo 103 comma 1 punto c), gli scarichi sul suolo devono rispettare i limiti previsti nella tabella 4. | Tabella 4 n. 18 · p. 230 |
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Nichel | 120 mg/kg | colonna A: siti ad uso verde pubblico, privato e residenziale | source |
| Nichel | 500 mg/kg | colonna B: siti ad uso commerciale e industriale | as above |
| Parameter | Value | Cite |
|---|---|---|
| Nichel | 20,0 ng/m³ | sourceNichel 20,0 ng/m3 |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Cite |
|---|---|
| 20 μg/l | source |
| Parameter | Value | Statistic | Applies when | Cite |
|---|---|---|---|---|
| Nickel (expressed as Ni) | 5,0-50 μg/l | annual average | activities specified in Section 4 of Annex I to Directive 2010/75/EU discharge to surface water The BAT-AEL applies if the emission exceeds 5,0 kg/yr | BAT 10, Tables 1-3Nickel (expressed as Ni) 5,0-50 μg/l |
| Value | Applies when | Cite |
|---|---|---|
| 20 ng/m³ | 31 December 2012 | ANNEX I Target values for arsenic, cadmium, nickel and benzo(a)pyreneNickel 20 ng/m 3 |
20 instruments we hold for Italy (IT) and European Union, for 19 names matching “nickel” (each in the JSON). 9 have a row, in the tables above; 11 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the nickel limits in Italy? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=nickel&place=IT; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.