Passage Data · Cited limits by place
20 numeric limits and guidelines for copper held for Yukon and the place above it, from 4 instruments, each cited to its instrument, edition, section or page and quoted text. The register was built from 247 instruments. Everything held for Yukon
The address to add: https://passage-data.com/mcp
https://passage-data.com/mcp.claude mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the copper limits in Yukon? Cite each one.”
For programs: this page as JSON at /api/v1/limits?parameter=copper&place=CA-YT; the same at https://passage-data.com/mcp, a remote MCP server (tool find_limits). llms.txt · OpenAPI
| Parameter | Value | Unit | Statistic | Governs | Applies when | Cite |
|---|---|---|---|---|---|---|
| copper | 20 @ H < 50 | µg/L | surface water · guideline | receiving water: freshwater water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) at H < 50 | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 | |
| copper | 30 @ H = 50 - < 75 | µg/L | surface water · guideline | receiving water: freshwater water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) at H = 50 - < 75 | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 | |
| copper | 40 @ H = 75 - < 100 | µg/L | surface water · guideline | receiving water: freshwater water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) at H = 75 - < 100 | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 | |
| copper | 50 @ H = 100 - < 125 | µg/L | surface water · guideline | receiving water: freshwater water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) at H = 100 - < 125 | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 | |
| copper | 60 @ H = 125 - < 150 | µg/L | surface water · guideline | receiving water: freshwater water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) at H = 125 - < 150 | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 | |
| copper | 70 @ H = 150 - < 175 | µg/L | surface water · guideline | receiving water: freshwater water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) at H = 150 - < 175 | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 | |
| copper | 80 @ H = 175 - < 200 | µg/L | surface water · guideline | receiving water: freshwater water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) at H = 175 - < 200 | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 | |
| copper | 90 @ H ≥ 200 | µg/L | surface water · guideline | receiving water: freshwater water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) at H ≥ 200 | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 | |
| copper | 20 | µg/L | surface water · guideline | receiving water: marine water used, or with a reasonable probability of being used, for aquatic life (s. 3: the site's water use decides which column of Schedule 3 binds); a site whose water exceeds it is a contaminated site (s. 2) assumes a minimum 1:10 dilution is available (note 2(a)) | Yukon Contaminated Sites Regulation (O.I.C. 2002/171) Schedule 3, Column II — aquatic life (AW) · p. 92 |
| Parameter | Value | Unit | Statistic | Governs | Applies when | Cite |
|---|---|---|---|---|---|---|
| Copper | 63 | mg/kg | soil · guideline | Concentration (mg/kg dry weight) Agricultural | CCME — Soil Quality Guidelines for the Protection of Environmental and Human Health (Summary Table,… | |
| Copper | 63 | mg/kg | soil · guideline | Concentration (mg/kg dry weight) Residential/ parkland | CCME — Soil Quality Guidelines for the Protection of Environmental and Human Health (Summary Table,… | |
| Copper | 91 | mg/kg | soil · guideline | Concentration (mg/kg dry weight) Commercial | CCME — Soil Quality Guidelines for the Protection of Environmental and Human Health (Summary Table,… | |
| Copper | 91 | mg/kg | soil · guideline | Concentration (mg/kg dry weight) Industrial | CCME — Soil Quality Guidelines for the Protection of Environmental and Human Health (Summary Table,… | |
| Copper | CWQG (µg/L) = 0.2 * e^{0.8545[ln(hardness)]-1.465} | µg/L | surface water · guideline | receiving water: freshwater long-term exposure: CCME's long-term guideline | CCME Canadian Water Quality Guidelines for the Protection of Aquatic Life | |
| Copper | 0.10 mg/L | mg/L | monthly average | effluent · limit | cites: MDMER route: direct a metal mine (or, since June 1, 2018, a diamond mine) whose final discharge points deposit more than 50 m3 of effluent per day (s. 2(1)) a mine to which the Regulations apply for the first time on or after June 1, 2021, or a recognized closed mine that returns to commercial operation on or after that day (s. 4(1)(a)(i)) | Metal and Diamond Mining Effluent Regulations (SOR/2002-222) Schedule 4, Table 1 — Column 2: maximum authorized monthly mean concentration 2 Copper 0.10 mg/L 0.15 mg/L 0.20 mg/L |
| Copper | 0.15 mg/L | mg/L | composite sample | effluent · limit | cites: MDMER route: direct a metal mine (or, since June 1, 2018, a diamond mine) whose final discharge points deposit more than 50 m3 of effluent per day (s. 2(1)) a mine to which the Regulations apply for the first time on or after June 1, 2021, or a recognized closed mine that returns to commercial operation on or after that day (s. 4(1)(a)(i)) | Metal and Diamond Mining Effluent Regulations (SOR/2002-222) Schedule 4, Table 1 — Column 3: maximum authorized concentration in a composite sample 2 Copper 0.10 mg/L 0.15 mg/L 0.20 mg/L |
| Copper | 0.20 mg/L | mg/L | instantaneous | effluent · limit | cites: MDMER route: direct a metal mine (or, since June 1, 2018, a diamond mine) whose final discharge points deposit more than 50 m3 of effluent per day (s. 2(1)) a mine to which the Regulations apply for the first time on or after June 1, 2021, or a recognized closed mine that returns to commercial operation on or after that day (s. 4(1)(a)(i)) | Metal and Diamond Mining Effluent Regulations (SOR/2002-222) Schedule 4, Table 1 — Column 4: maximum authorized concentration in a grab sample 2 Copper 0.10 mg/L 0.15 mg/L 0.20 mg/L |
| Copper | 0.30 mg/L | mg/L | monthly average | effluent · limit | cites: MDMER route: direct a metal mine (or, since June 1, 2018, a diamond mine) whose final discharge points deposit more than 50 m3 of effluent per day (s. 2(1)) any other mine (s. 4(1)(a)(ii)) | Metal and Diamond Mining Effluent Regulations (SOR/2002-222) Schedule 4, Table 2 — Column 2: maximum authorized monthly mean concentration 2 Copper 0.30 mg/L 0.45 mg/L 0.60 mg/L |
| Copper | 0.45 mg/L | mg/L | composite sample | effluent · limit | cites: MDMER route: direct a metal mine (or, since June 1, 2018, a diamond mine) whose final discharge points deposit more than 50 m3 of effluent per day (s. 2(1)) any other mine (s. 4(1)(a)(ii)) | Metal and Diamond Mining Effluent Regulations (SOR/2002-222) Schedule 4, Table 2 — Column 3: maximum authorized concentration in a composite sample 2 Copper 0.30 mg/L 0.45 mg/L 0.60 mg/L |
| Copper | 0.60 mg/L | mg/L | instantaneous | effluent · limit | cites: MDMER route: direct a metal mine (or, since June 1, 2018, a diamond mine) whose final discharge points deposit more than 50 m3 of effluent per day (s. 2(1)) any other mine (s. 4(1)(a)(ii)) | Metal and Diamond Mining Effluent Regulations (SOR/2002-222) Schedule 4, Table 2 — Column 4: maximum authorized concentration in a grab sample 2 Copper 0.30 mg/L 0.45 mg/L 0.60 mg/L |
Not held here: a discharge permit's own limits, and any rule for copper outside the 12 instruments we hold for this place and the places above it. A row missing here is missing from our sources, not from the law.
Free check: send your permit or your lab results, and we check each number against these rows, every verdict cited to its page, by email within 5 business days. Or send the link to a rule we do not hold: we read it and cite it by page.
Every instrument we hold for Yukon (CA-YT) and the place above it, Canada (CA): 12 instruments, for every parameter name matching “copper”: copper, copper total, copper cyanide, copper i cyanide, copper cyanide cucn, total copper marine, copper cyanide cu cn, total copper freshwater, copper total recoverable, arsenic cadmium h copper h lead h zinc h, cadmium h copper h mercury lead h zinc h, arsenic cadmium h copper h lead h mercury zinc h, and 1 more (in the JSON).
36cce6388db5486bb2c03ea86b7433a45251f146a6aab5d179c0c298d68ce722 — 9 rows here2c6e0151d3776378f73df4868ca98052882ee81faf9738bbeba6f5d544b648fe — 6 rows heref484a5f2a2dfcb5a4257763c853fc8dc810788cec54c75355b30ec194e2f7499 — 4 rows heref484a5f2a2dfcb5a4257763c853fc8dc810788cec54c75355b30ec194e2f7499 — 1 row heredb95b0a149728b0f0b1e1b1314d87ecdf46a91e1edfec4a7006fc3cbe0080bd6 — no row here32a42a0d382cdd90729dd9750f47889782bd00d4af8dfd34f2b9aaf6f2678c6c — no row herec60e2a2dfa9a10c2ddd314b391bf66215ad599732f38b4c5a15fe793d8c28841 — no row here691ca3953a6dd6ae66b4c72737944caa68ed76710447df642a16716dd25027a3 — no row herecc8432e6a4dd1834ff4dd43d5b5fb98f09b1f7af7952e36154febcc649504eb4 — no row here30e528bdc3a3546afb3defff4dae9b1dacb362e192680e127bd788d7f97c8ce8 — no row here0a60e10f783f7aca672792303dffcca1525133eb34eb32711543cb3cf4bbb955 — no row hereRead from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.