Passage Data · Cited limits by place · Use it from your AI

pH limits and guidelines in Québec (CA-QC)

16 cited rows from 10 instruments, Québec's own first. Not covered: a permit's own limits, or rules outside the 24 instruments we hold for Québec (CA-QC) and Canada. Everything held for Québec

Québec: surface water 3, effluent 2 · Canada: drinking water 1, surface water 2, effluent 4, soil 4

Québec (CA-QC): 5 rows

Surface water: 3 rows

Critères de qualité de l'eau de surface (MELCCFP) · répertoire en ligne du MELCCFP, chaque fiche telle que servie le 2026-10-09 · 3 guidelines · Source changed on or before 2026-10-22, not yet re-read: these rows are as read from répertoire en ligne du MELCCFP, chaque fiche telle que servie le 2026-10-09 (each row names its fiche, its URL and its sha256).
ValueApplies whenCite
Voir l' annexe 13 pour obtenir le sommaire des effets létaux du pH sur les poissons. unité de pHreceiving water: freshwaterfiche S0381 (pH) — critère de vie aquatique aigu (CVAA)
(CCMRE, 1987) Voir l' annexe 13 pour obtenir le sommaire des effets létaux du pH sur les poissons.
6,5 à 9,0 unité de pHas abovefiche S0381 (pH) — critère de vie aquatique chronique (CVAC)
6,5 à 9,0 (CCMRE, 1987; U.S.EPA, 2006a)
7,0 à 8,7 unité de pHreceiving water: marinefiche S0381 (pH) — critère de vie aquatique chronique (CVAC)
7,0 à 8,7 (CCME, 2002) Cette concentration s'applique aux eaux saumâtres et salées.

Effluent: 2 rows

Règlement sur les fabriques de pâtes et papiers (RLRQ, c. Q-2, r. 27) · LégisQuébec, à jour au 1er juin 2026 · 1 limit · Source changed on or before 2026-10-17, not yet re-read: these rows are as read from LégisQuébec, à jour au 1er juin 2026.
ValueApplies whenCite
entre 6,0 et 9,5 pH unitstout effluent final rejeté dans l'environnement ou dans un égout pluvial
sauf l'effluent final des eaux de refroidissement, dont le pH peut être égal à celui de l'eau d'alimentation
a. 12 · p. 8
12. Tout effluent final rejeté dans l’environnement ou dans un égout pluvial doit avoir un pH qui se situe entre 6,0 et 9,5. Toutefois, le pH de l’effluent final des eaux de refroidissement peut être égal à celui de l’eau d’alimentation.
Règlement sur les ouvrages municipaux d'assainissement des eaux usées (RLRQ, c. Q-2, r. 34.1) — a. 6 normes de rejet · LégisQuébec, à jour au 1er juin 2026 · 1 limit · Source changed on or before 2026-10-17, not yet re-read: these rows are as read from LégisQuébec, à jour au 1er juin 2026.
ValueApplies whenCite
entre 6,0 et 9,5 pH unitsstream: sanitary
discharge to surface water
l'effluent d'une station d'épuration d'un ouvrage municipal d'assainissement des eaux usées (a. 6)
a. 6, 3° · p. 5
3° la valeur de potentiel hydrogène (pH) doit se situer entre 6,0 et 9,5.

Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.

Canada (CA): 11 rows

Drinking water: 1 row

Health Canada — Guidelines for Canadian Drinking Water Quality, Summary Tables 1-3 (microbiological, chemical and… · page modified 2026-01-21 · 1 guideline
ValueApplies whenCite
7.0-10.5drinking water (a guideline, not a regulation: each province and territory decides whether, and how, it binds there)Table 2, Chemical and Physical Parameters (pH, published or reaffirmed 2015)
T pH (2015) None 7.0-10.5 Table 2 footnote 4

Surface water: 2 rows

CCME Canadian Water Quality Guidelines for the Protection of Aquatic Life — freshwater and marine, short and long term · Summary Table (as served 2026-09-24; each guideline carries its own year) · 2 guidelines
Every row: long-term exposure: CCME's long-term guideline
ValueApplies whenCite
6.5 to 9.0 µg/Lreceiving water: freshwatersource
7.0 to 8.7 & Narrative µg/Lreceiving water: marineas above

Effluent: 4 rows

Meat and Poultry Products Plant Liquid Effluent Regulations (C.R.C., c. 818) — Schedule I authorized deposits · Justice Laws Website, current to 2026-09-21 · 1 limit
ValueStatisticApplies whenCite
between 6.0 and 9.0 pH unitscomposite sampledischarge to surface water
a new plant (commercial production from March 31, 1977) or an expanded plant (s. 3; s. 2(1))
s. 5(c)
(c) the pH of each composite sample of effluent, determined in accordance with subsection 9(3), is between 6.0 and 9.0.
Metal and Diamond Mining Effluent Regulations (SOR/2002-222) — Schedule 4, maximum authorized concentrations · Justice Laws Website, current to 2026-09-21 · 1 limit
ValueApplies whenCite
equal to or greater than 6.0 but is not greater than 9.5 pH unitsdischarge to surface water
a metal mine (or, since June 1, 2018, a diamond mine) whose final discharge points deposit more than 50 m3 of effluent per day (s. 2(1))
s. 4(1)(b)
(b) the pH of the effluent is equal to or greater than 6.0 but is not greater than 9.5; and (c) the effluent is not acutely lethal.
Petroleum Refinery Liquid Effluent Regulations (C.R.C., c. 828) — Schedule I authorized deposits · Justice Laws Website, current to 2026-09-21 · 1 limit
ValueApplies whenCite
within the limits of 6.0 and 9.5 pH unitsdischarge to surface waters. 5(2)
the owner of a refinery may deposit the deleterious substance prescribed in paragraph 4(f) if the pH of the liquid effluent or once-through cooling water is within the limits of 6.0 and 9.5.
Potato Processing Plant Liquid Effluent Regulations (C.R.C., c. 829) — Schedule I authorized deposits · Justice Laws Website, current to 2026-09-21 · 1 limit
ValueStatisticApplies whenCite
between 6.0 and 9.0 pH unitscomposite sampledischarge to surface water
a new plant (commercial production from June 27, 1977) or an expanded plant (s. 3; s. 2(1))
s. 5(c)
(c) the pH of each composite sample of effluent, determined in accordance with subsection 9(3), is between 6.0 and 9.0.

Soil: 4 rows

CCME — Soil Quality Guidelines for the Protection of Environmental and Human Health (Summary Table, as served… · Summary Table · 4 guidelines
ValueApplies whenCite
6 to 8 mg/kgConcentration (mg/kg dry weight) Agriculturalsource
6 to 8 mg/kgConcentration (mg/kg dry weight) Residential/ parklandas above
6 to 8 mg/kgConcentration (mg/kg dry weight) Commercialas above
6 to 8 mg/kgConcentration (mg/kg dry weight) Industrialas above

What was searched

24 instruments we hold for Québec (CA-QC) and Canada, for 17 names matching “ph” (each in the JSON). 10 have a row, in the tables above; 14 have none.

14 instruments with no row for ph
  1. Calcul et interprétation des objectifs environnementaux de rejet (OER) — méthode · MELCCFP 2022 (PDF, fetched 2026-09-25)
  2. Canadian Ambient Air Quality Standards (CAAQS), environmental quality objectives under CEPA 1999 ss. 54(1) and 55(1) · Canada Gazette, Part I, Volume 147, Number 21: GOVERNMENT NOTICES May 25, 2013
  3. Critères de qualité de l'eau de surface — Chlorures (S0118) · MELCCFP, critères de qualité de l'eau de surface (fetched 2026-09-25) · Source changed on or before 2026-10-22, not yet re-read: these rows are as read from MELCCFP, critères de qualité de l'eau de surface (fetched 2026-09-25).
  4. Critères de qualité de l'eau de surface — Fluorures, annexe 19 (valeurs selon la dureté) · MELCCFP, critères de qualité de l'eau de surface, annexe 19 (fetched 2026-09-25)
  5. Critères de qualité de l'eau de surface — Sulfates (S0424) · MELCCFP, critères de qualité de l'eau de surface (fetched 2026-09-25) · Source changed on or before 2026-10-22, not yet re-read: these rows are as read from MELCCFP, critères de qualité de l'eau de surface (fetched 2026-09-25).
  6. Directive 019 sur l'industrie minière (février 2025) — tableau 3.1, exigences au point de rejet de l'effluent final · février 2025
  7. Fisheries Act (R.S.C. 1985, c. F-14), s. 36(3) · Justice Laws Website, current to 2026-09-21, last amended 2024-11-27
  8. Guide d'intervention — Annexe 2 : Grille des critères génériques pour les sols
  9. Guide d'intervention — Annexe 7 : Grille des critères de qualité des eaux souterraines · mai 2021
  10. Health Canada, Objective for Canadian drinking water quality · Objective value
  11. MELCCFP — Normes et critères québécois de qualité de l'atmosphère (version 11) · Version 11
  12. Pulp and Paper Effluent Regulations (SOR/92-269) — s. 14 maximum BOD and suspended solids · Justice Laws Website, current to 2026-09-21
  13. Règlement sur la qualité de l'eau potable (chapitre Q-2, r. 40), Annexe 1 · À jour au 1er mai 2026
  14. Wastewater Systems Effluent Regulations (SOR/2012-139) — s. 6 effluent quality · Justice Laws Website, current to 2026-09-21, last amended 2026-06-04
Add Passage Data to your AI assistant (free, no key)

The address: https://passage-data.com/mcp

In a chat app

In a coding tool

Then ask it, for example: “What are the ph limits in Québec? Cite each one.”

Programs: this page as JSON at /api/v1/limits?parameter=ph&place=CA-QC; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.