Passage Data · Cited limits by place · Use it from your AI

Fluorine limits and guidelines in Québec (CA-QC)

8 cited rows from 4 instruments, Québec's own first. Not covered: a permit's own limits, or rules outside the 24 instruments we hold for Québec (CA-QC) and Canada. Everything held for Québec

Québec: ambient air 2 · Canada: drinking water 1, surface water 1, soil 4

Québec (CA-QC): 2 rows

Ambient air: 2 rows

MELCCFP — Normes et critères québécois de qualité de l'atmosphère (version 11) · Version 11 · 2 guidelines
ParameterValueStatisticCite
Fluor0.67 µg/m³1-hour averagesource
Fluor0.0004 µg/m³annual averageas above

Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.

Canada (CA): 6 rows

Drinking water: 1 row

Health Canada — Guidelines for Canadian Drinking Water Quality, Summary Tables 1-3 (microbiological, chemical and… · page modified 2026-01-21 · 1 guideline
ParameterValueApplies whenCite
Fluoride1.5 mg/Ldrinking water (a guideline, not a regulation: each province and territory decides whether, and how, it binds there)Table 2, Chemical and Physical Parameters (Fluoride, published or reaffirmed 2010)
I Fluoride (2010) 1.5 None

Surface water: 1 row

CCME Canadian Water Quality Guidelines for the Protection of Aquatic Life — freshwater and marine, short and long term · Summary Table (as served 2026-09-24; each guideline carries its own year) · 1 guideline
ParameterValueApplies whenCite
Fluoride120 µg/Lreceiving water: freshwater
long-term exposure: CCME's long-term guideline
source

Soil: 4 rows

CCME — Soil Quality Guidelines for the Protection of Environmental and Human Health (Summary Table, as served… · Summary Table · 4 guidelines
ParameterValueApplies whenCite
Fluoride200 mg/kgConcentration (mg/kg dry weight) Agriculturalsource
Fluoride400 mg/kgConcentration (mg/kg dry weight) Residential/ parklandas above
Fluoride2000 mg/kgConcentration (mg/kg dry weight) Commercialas above
Fluoride2000 mg/kgConcentration (mg/kg dry weight) Industrialas above

What was searched

24 instruments we hold for Québec (CA-QC) and Canada, for 14 names matching “fluorine” (each in the JSON). 4 have a row, in the tables above; 20 have none.

20 instruments with no row for fluorine
  1. Calcul et interprétation des objectifs environnementaux de rejet (OER) — méthode · MELCCFP 2022 (PDF, fetched 2026-09-25)
  2. Canadian Ambient Air Quality Standards (CAAQS), environmental quality objectives under CEPA 1999 ss. 54(1) and 55(1) · Canada Gazette, Part I, Volume 147, Number 21: GOVERNMENT NOTICES May 25, 2013
  3. Critères de qualité de l'eau de surface — Chlorures (S0118) · MELCCFP, critères de qualité de l'eau de surface (fetched 2026-09-25) · Source changed on or before 2026-10-22, not yet re-read: these rows are as read from MELCCFP, critères de qualité de l'eau de surface (fetched 2026-09-25).
  4. Critères de qualité de l'eau de surface — Fluorures, annexe 19 (valeurs selon la dureté) · MELCCFP, critères de qualité de l'eau de surface, annexe 19 (fetched 2026-09-25)
  5. Critères de qualité de l'eau de surface — Sulfates (S0424) · MELCCFP, critères de qualité de l'eau de surface (fetched 2026-09-25) · Source changed on or before 2026-10-22, not yet re-read: these rows are as read from MELCCFP, critères de qualité de l'eau de surface (fetched 2026-09-25).
  6. Critères de qualité de l'eau de surface (MELCCFP) · répertoire en ligne du MELCCFP, chaque fiche telle que servie le 2026-10-09 · Source changed on or before 2026-10-22, not yet re-read: these rows are as read from répertoire en ligne du MELCCFP, chaque fiche telle que servie le 2026-10-09 (each row names its fiche, its URL and its sha256).
  7. Directive 019 sur l'industrie minière (février 2025) — tableau 3.1, exigences au point de rejet de l'effluent final · février 2025
  8. Fisheries Act (R.S.C. 1985, c. F-14), s. 36(3) · Justice Laws Website, current to 2026-09-21, last amended 2024-11-27
  9. Guide d'intervention — Annexe 2 : Grille des critères génériques pour les sols
  10. Guide d'intervention — Annexe 7 : Grille des critères de qualité des eaux souterraines · mai 2021
  11. Health Canada, Objective for Canadian drinking water quality · Objective value
  12. Meat and Poultry Products Plant Liquid Effluent Regulations (C.R.C., c. 818) — Schedule I authorized deposits · Justice Laws Website, current to 2026-09-21
  13. Metal and Diamond Mining Effluent Regulations (SOR/2002-222) — Schedule 4, maximum authorized concentrations · Justice Laws Website, current to 2026-09-21
  14. Petroleum Refinery Liquid Effluent Regulations (C.R.C., c. 828) — Schedule I authorized deposits · Justice Laws Website, current to 2026-09-21
  15. Potato Processing Plant Liquid Effluent Regulations (C.R.C., c. 829) — Schedule I authorized deposits · Justice Laws Website, current to 2026-09-21
  16. Pulp and Paper Effluent Regulations (SOR/92-269) — s. 14 maximum BOD and suspended solids · Justice Laws Website, current to 2026-09-21
  17. Règlement sur la qualité de l'eau potable (chapitre Q-2, r. 40), Annexe 1 · À jour au 1er mai 2026
  18. Règlement sur les fabriques de pâtes et papiers (RLRQ, c. Q-2, r. 27) · LégisQuébec, à jour au 1er juin 2026 · Source changed on or before 2026-10-17, not yet re-read: these rows are as read from LégisQuébec, à jour au 1er juin 2026.
  19. Règlement sur les ouvrages municipaux d'assainissement des eaux usées (RLRQ, c. Q-2, r. 34.1) — a. 6 normes de rejet · LégisQuébec, à jour au 1er juin 2026 · Source changed on or before 2026-10-17, not yet re-read: these rows are as read from LégisQuébec, à jour au 1er juin 2026.
  20. Wastewater Systems Effluent Regulations (SOR/2012-139) — s. 6 effluent quality · Justice Laws Website, current to 2026-09-21, last amended 2026-06-04
Add Passage Data to your AI assistant (free, no key)

The address: https://passage-data.com/mcp

In a chat app

In a coding tool

Then ask it, for example: “What are the fluorine limits in Québec? Cite each one.”

Programs: this page as JSON at /api/v1/limits?parameter=fluorine&place=CA-QC; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI

Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.