Passage Data · Cited limits by place · Use it from your AI
6 cited rows from 3 instruments, Manitoba's own first. Not covered: a permit's own limits, or rules outside the 13 instruments we hold for Manitoba (CA-MB) and Canada. Everything held for Manitoba
Manitoba: surface water 1 · Canada: drinking water 3, surface water 2
| Parameter | Value | Applies when | Cite |
|---|---|---|---|
| Total Suspended Sediment or Turbidity | 5 mg/L Induced Change from Background(j) and 25 mg/L Induced Change from Background and 10 % Induced Change from Background Equivalent Induced Levels of Change as Calculated From Site- Specific or Regional-Specific Correlation Between Total Suspended Sediment and Turbidity mg/L NTU | water use as printed: Surface Water: Aquatic Life and Wildlife applicable period as printed: Background Total Suspended Sediment ≤25 mg/L Background Total Suspended Sediment ≤250mg/L Background Total Suspended Sediment >250 mg/L an equation (hardness, pH or temperature) or a set of values, carried as printed and never evaluated | Tier II - Water Quality Objectives: Total Suspended Sediment or Turbidity · Surface Water: Aquatic Life and Wildlife · p. 32 |
Free check: send your permit or lab results and we check each number against the limits that apply here, each verdict cited to its page, by email within 5 business days. Or send a link to a rule we do not hold: we read it and cite it by page.
| Value | Applies when | Cite |
|---|---|---|
| ≤ 0.3 NTU | water leaving an individual filter or unit: conventional and direct filtration in at least 95% of measurements either per filter cycle or per month; never to exceed 1.0 NTU. | Table 1, Microbiological Parameters (Turbidity, 2012)Conventional and direct filtration: ≤ 0.3 NTU |
| ≤ 1.0 NTU | water leaving an individual filter or unit: slow sand and diatomaceous earth filtration in at least 95% of measurements either per filter cycle or per month; never to exceed 3.0 NTU. | Table 1, Microbiological Parameters (Turbidity, 2012)slow sand and diatomaceous earth filtration: ≤ 1.0 NTU |
| ≤ 0.1 NTU | water leaving an individual filter or unit: membrane filtration in at least 99% of measurements per operational filter period or per month. Measurements greater than 0.1 NTU for a period greater than 15 minutes from an individual membrane unit should immediately trigger an investigation of the membrane unit integrity. | Table 1, Microbiological Parameters (Turbidity, 2012)membrane filtration: ≤ 0.1 NTU |
| Value | Applies when | Cite |
|---|---|---|
| Narrative | receiving water: freshwater | source |
| Narrative | receiving water: marine | as above |
13 instruments we hold for Manitoba (CA-MB) and Canada, for 4 names matching “turbidity” (each in the JSON). 3 have a row, in the tables above; 10 have none.
The address: https://passage-data.com/mcp
In a chat app
In a coding tool
claude mcp add --transport http passage-data https://passage-data.com/mcp codex mcp add passage-data --url https://passage-data.com/mcp gemini mcp add --transport http passage-data https://passage-data.com/mcp Then ask it, for example: “What are the turbidity limits in Manitoba? Cite each one.”
Programs: this page as JSON at /api/v1/limits?parameter=turbidity&place=CA-MB; MCP at https://passage-data.com/mcp (tool find_limits). Every tool · llms.txt · OpenAPI
Read from public law and public agency files. A row missing here is missing from our sources, not from the law of the place. Check the cited source before relying on a value.