{"state":"FL","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/FL","listed":"individual NPDES permits with limits in EPA's file; a general permit's coverages are not listed"},"filter":{"industry":null,"sic":null,"matched_on":"EPA's primary SIC code and its description","over_limit":null,"parameter":"oil and grease","renewal":null,"upcoming":null,"facility_type":null,"min_flow_mgd":null},"of":378,"without_industry":0,"matched":3,"offset":0,"returned":3,"screen":{"of":378,"window":["2025-10-01","2026-09-30"],"with_record":378,"without_record":0,"over_limit":134,"missing_values":59,"parameters_over":[{"parameter":"Nitrogen, total [as N]","permits":36},{"parameter":"IC25 Static Renewal 7 Day Chronic Ceriodaphnia dubia","permits":28},{"parameter":"Phosphorus, total [as P]","permits":22},{"parameter":"Coliform, fecal general","permits":20},{"parameter":"BOD, carbonaceous [5 day, 20 C]","permits":14},{"parameter":"Solids, total suspended","permits":13},{"parameter":"Chlorine, total residual","permits":11},{"parameter":"Nitrogen, ammonia total [as N]","permits":10},{"parameter":"Oxygen, dissolved percent saturation","permits":9},{"parameter":"Enterococci: group D, MF trans, M-E, EIA","permits":8},{"parameter":"Flow, in conduit or thru treatment plant","permits":8},{"parameter":"pH","permits":8},{"parameter":"% of fecal coliform samples < detectable","permits":7},{"parameter":"Cyanide, total [as CN]","permits":7},{"parameter":"Specific conductance","permits":7},{"parameter":"Copper, total recoverable","permits":6},{"parameter":"Oxygen, dissolved [DO]","permits":6},{"parameter":"Dichlorobromomethane","permits":4},{"parameter":"E. coli","permits":4},{"parameter":"IC25 Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","permits":3}],"parameters_over_more":27,"renewal":{"permit_expired":59,"application_overdue":26,"application_due_within_18_months":107},"upcoming":10,"upcoming_above_today":2,"says":"Of the 378 permits listed in FL, 134 went over a limit between 2025-10-01 and 2026-09-30 (Nitrogen, total [as N]: 36; IC25 Static Renewal 7 Day Chronic Ceriodaphnia dubia: 28; Phosphorus, total [as P]: 22). 59 are past the expiry date EPA's file holds; 133 have a renewal application overdue or due within 18 months; 10 have a new or tighter limit taking effect later, 2 already reporting above it today. EPA's file of 2026-10-22.","narrow":{"renewal_expired":"https://passage-data.com/api/v1/permits?state=FL&renewal=expired","renewal_due":"https://passage-data.com/api/v1/permits?state=FL&renewal=due","upcoming":"https://passage-data.com/api/v1/permits?state=FL&upcoming=true"}},"permits":[{"permit":"FL0024805","name":"Miami-Dade County - Public Works Department","major":true,"sic":"4952","industry":"Sewerage Systems","record":{"over":15,"over_by":[["Chlorine, total residual",11],["Oil & Grease",4]],"missing":0},"expires":"2025-12-31","renewal":{"status":"permit_expired","application_due":"2025-07-04"},"design_flow_mgd":"143","facility_type":"POTW","upcoming":[],"page":"https://passage-data.com/dmr/p/FL0024805","json":"https://passage-data.com/api/v1/permits/FL0024805"},{"permit":"FL0036498","name":"Seminole Electric","major":true,"sic":"4911","industry":"Electric Services","record":{"over":7,"over_by":[["Mercury, total recoverable",5],["Oil & Grease",2]],"missing":0},"expires":"2030-06-24","renewal":null,"design_flow_mgd":"7.46","facility_type":"NON-POTW","upcoming":[],"page":"https://passage-data.com/dmr/p/FL0036498","json":"https://passage-data.com/api/v1/permits/FL0036498"},{"permit":"FL0122904","name":"Watco Port Sutton Terminal, L.L.C.","major":false,"sic":"4226","industry":"Special Warehousing And Storage","record":{"over":1,"over_by":[["Oil & Grease",1]],"missing":0},"expires":"2026-11-15","renewal":{"status":"permit_expired","application_due":"2026-05-19"},"design_flow_mgd":null,"facility_type":"NON-POTW","upcoming":[],"page":"https://passage-data.com/dmr/p/FL0122904","json":"https://passage-data.com/api/v1/permits/FL0122904"}]}