{"state":"OR","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/OR","listed":"individual NPDES permits with limits in EPA's file; a general permit's coverages are not listed"},"filter":{"industry":null,"sic":null,"matched_on":"EPA's primary SIC code and its description","over_limit":null,"parameter":"cyanide","renewal":null,"upcoming":null,"facility_type":null,"min_flow_mgd":null},"of":300,"without_industry":0,"matched":1,"offset":0,"returned":1,"screen":{"of":300,"window":["2025-10-01","2026-09-30"],"with_record":299,"without_record":1,"over_limit":91,"missing_values":45,"parameters_over":[{"parameter":"BOD, 5-day, 20 deg. C","permits":32},{"parameter":"Solids, total suspended","permits":21},{"parameter":"BOD, 5-day, percent removal","permits":15},{"parameter":"pH","permits":14},{"parameter":"E. coli","permits":12},{"parameter":"Nitrogen, ammonia total [as N]","permits":8},{"parameter":"Excess thermal load","permits":7},{"parameter":"Oil & Grease","permits":7},{"parameter":"Solids, suspended percent removal","permits":7},{"parameter":"Chlorine, total residual","permits":4},{"parameter":"pH range excursions, > 60 minutes","permits":3},{"parameter":"Phosphorus, total [as P]","permits":3},{"parameter":"BOD, carbonaceous [5 day, 20 C]","permits":2},{"parameter":"Coliform, fecal - % samples exceeding limit","permits":2},{"parameter":"Arsenic, Inorganic","permits":1},{"parameter":"Coliform, fecal general","permits":1},{"parameter":"Copper, total [as Cu]","permits":1},{"parameter":"Cyanide, total [as CN]","permits":1},{"parameter":"Dilution factor","permits":1},{"parameter":"E. coli, MTEC-MF","permits":1}],"parameters_over_more":8,"renewal":{"permit_expired":166,"application_overdue":13,"application_due_within_18_months":42},"upcoming":16,"upcoming_above_today":8,"says":"Of the 300 permits listed in OR, 91 went over a limit between 2025-10-01 and 2026-09-30 (BOD, 5-day, 20 deg. C: 32; Solids, total suspended: 21; BOD, 5-day, percent removal: 15); 1 has no reports in EPA's file for that window. 166 are past the expiry date EPA's file holds; 55 have a renewal application overdue or due within 18 months; 16 have a new or tighter limit taking effect later, 8 already reporting above it today. EPA's file of 2026-10-22.","narrow":{"renewal_expired":"https://passage-data.com/api/v1/permits?state=OR&renewal=expired","renewal_due":"https://passage-data.com/api/v1/permits?state=OR&renewal=due","upcoming":"https://passage-data.com/api/v1/permits?state=OR&upcoming=true"}},"permits":[{"permit":"OR0031127","name":"ASC SUNSTONE CIRCUITS LLC","major":false,"sic":"3672","industry":"Printed Circuit Boards","record":{"over":10,"over_by":[["Cyanide, total [as CN]",10]],"missing":0},"expires":"2030-05-31","renewal":null,"design_flow_mgd":null,"facility_type":"NON-POTW","upcoming":[{"parameter":"Cadmium, total recoverable","outfall":"001","limit":0.011,"unit":"mg/L","statistic":"daily maximum","statistic_code":"DD","begin":"2028-08-01","kind":"tighter","now":{"median":0.00025,"n":12,"below_detection":12}},{"parameter":"Cadmium, total recoverable","outfall":"001","limit":0.005,"unit":"mg/L","statistic":"monthly average","statistic_code":"MK","begin":"2028-08-01","kind":"tighter","now":{"median":0.00025,"n":12,"below_detection":12}},{"parameter":"Copper, total recoverable","outfall":"001","limit":0.041,"unit":"mg/L","statistic":"daily maximum","statistic_code":"DD","begin":"2028-08-01","kind":"tighter","now":{"median":0.06155,"n":12},"times_limit":1.5},{"parameter":"Copper, total recoverable","outfall":"001","limit":0.02,"unit":"mg/L","statistic":"monthly average","statistic_code":"MK","begin":"2028-08-01","kind":"tighter","now":{"median":0.04335,"n":12},"times_limit":2.17}],"page":"https://passage-data.com/dmr/p/OR0031127","json":"https://passage-data.com/api/v1/permits/OR0031127"}]}