{"permit":"WV1026488","name":"NEWGATE DEVELOPMENT OF BECKLEY LLC","state":"WV","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/WV1026488"},"about":[{"label":"What it is","text":"Bituminous Coal And Lignite - Surface (EPA's industry listing)"},{"label":"Where","text":"Beckley, West Virginia","href":"https://www.openstreetmap.org/?mlat=37.66&mlon=-81.3133#map=14/37.66/-81.3133"},{"label":"Last 12 months","text":"Over a limit 8 times, last in February 2026 (Aluminum, total [as Al]; Solids, total suspended; Iron, total [as Fe]). 2 required values not reported. 113 of 339 reports filed late"},{"label":"Permit","text":"Expired Sep 10, 2025; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2025-03-14","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/WV1026488#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"WV","sic":"12","permits":1301,"list":"https://passage-data.com/api/v1/permits?state=WV&sic=12","page":"https://passage-data.com/dmr/s/WV/12"},"limits_from_version":null,"record":{"last_filed":"2026-06-30","over":8,"over_by":[["Aluminum, total [as Al]",4],["Solids, total suspended",2],["Iron, total [as Fe]",2]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Aluminum, total [as Al]","times":4,"find_limits":{"parameter":"aluminum","place":"US-WV","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=aluminum&place=US-WV&medium=surface_water"},{"parameter":"Solids, total suspended","times":2,"find_limits":{"parameter":"total suspended solids","place":"US-WV","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-WV&medium=water_discharge"},{"parameter":"Iron, total [as Fe]","times":2,"find_limits":{"parameter":"iron","place":"US-WV","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=iron&place=US-WV&medium=surface_water"}],"limits":[{"outfall":"001","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"004","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"005","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"006","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Toxicity [chronic], Ceriodaphnia dubia","parameter_code":"61426","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"tox chronic","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Toxicity [chronic], Ceriodaphnia dubia","parameter_code":"61426","statistic":"monthly average","qualifier":null,"value":null,"unit":"tox chronic","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Toxicity [chronic], Ceriodaphnia dubia","parameter_code":"61426","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"tox chronic","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"007","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"008","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"009","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".95","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":"1.64","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"010","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".95","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":"1.64","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"011","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".95","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":"1.64","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"012","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"013","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"014","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"015","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"016","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"017","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"018","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"019","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Flow rate","parameter_code":"00058","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":".34","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS009DS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BAS025DS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGDS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGMP","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Alkalinity, total [as CaCO3]","parameter_code":"00410","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Calcium, total [as Ca]","parameter_code":"00916","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Magnesium, total [as Mg]","parameter_code":"00927","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Sodium, total [as Na]","parameter_code":"00929","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Potassium, total [as K]","parameter_code":"00937","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"BASWGUS","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSBB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSMB1","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"DSWG1","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USBB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USMB1","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"USWG","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly average","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Stream flow, instantaneous","parameter_code":"00061","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"cfs","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly average","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Specific conductance","parameter_code":"00095","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"umho/cm","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Sulfate, total [as SO4]","parameter_code":"00945","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"UTMB1","parameter":"Solids, total dissolved","parameter_code":"70295","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"WV","sic":"12"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=WV&sic=12","url":"https://passage-data.com/api/v1/permits?state=WV&sic=12","page":"https://passage-data.com/dmr/s/WV/12"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"aluminum","place":"US-WV","medium":"surface_water"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=aluminum&place=US-WV&medium=surface_water","url":"https://passage-data.com/api/v1/limits?parameter=aluminum&place=US-WV&medium=surface_water","page":"https://passage-data.com/limits/US-WV/aluminum"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"WV1026488"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=WV1026488"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"WV1026488"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=WV1026488"}]}