{"permit":"VT0000400","name":"GLOBALFOUNDRIES","state":"VT","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/VT0000400"},"about":[{"label":"What it is","text":"Industrial or other facility · rated a major discharger by EPA"},{"label":"Where","text":"Essex Junction, Vermont","href":"https://www.openstreetmap.org/?mlat=44.481636&mlon=-73.090622#map=14/44.481636/-73.090622"},{"label":"Last 12 months","text":"Over a limit once, last in March 2026 (Copper, total [as Cu]). 1 of 14 reports filed late"},{"label":"Permit","text":"Expired Mar 31, 2026; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2025-10-02","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/VT0000400#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":null,"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":1,"over_by":[["Copper, total [as Cu]",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Copper, total [as Cu]","times":1,"find_limits":{"parameter":"copper","place":"US-VT","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=copper&place=US-VT&medium=surface_water"}],"limits":[{"outfall":"001","parameter":"Hydrogen peroxide","parameter_code":"00139","statistic":"30-day average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Hydrogen peroxide","parameter_code":"00139","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oxygen demand, ultimate","parameter_code":"00181","statistic":"daily maximum","qualifier":"<=","value":"2300","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"10.5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"437","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"26","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"26","unit":"mg/L","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"52","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"52","unit":"mg/L","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"1734.72","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"1734.72","unit":"lb/d","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"3469.44","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"3469.44","unit":"lb/d","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"30-day average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"monthly average","qualifier":"<=","value":".8","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"annual total","qualifier":"<=","value":"4872","unit":"lb/yr","report_only":false,"enforceable":true,"months":["DEC"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cyanide, free [amenable to chlorination]","parameter_code":"00722","statistic":"monthly average","qualifier":"<=","value":".65","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cyanide, free [amenable to chlorination]","parameter_code":"00722","statistic":"daily maximum","qualifier":"<=","value":"1.2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cyanide, free [amenable to chlorination]","parameter_code":"00722","statistic":"monthly average","qualifier":"<=","value":"4.77","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cyanide, free [amenable to chlorination]","parameter_code":"00722","statistic":"daily maximum","qualifier":"<=","value":"6.97","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"30-day average","qualifier":"<=","value":"17.4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"daily maximum","qualifier":"<=","value":"28","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"monthly average","qualifier":"<=","value":".07","unit":"mg/L","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"monthly average","qualifier":"<=","value":".07","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":"<=","value":".11","unit":"mg/L","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":"<=","value":".11","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"monthly average","qualifier":"<=","value":".42","unit":"lb/d","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"monthly average","qualifier":"<=","value":".42","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":"<=","value":".62","unit":"lb/d","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":"<=","value":".62","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":"1.71","unit":"mg/L","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":"1.71","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"2.77","unit":"mg/L","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"2.77","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":"45.7","unit":"lb/d","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":"45.7","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"66.7","unit":"lb/d","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"66.7","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":"2.07","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"3.38","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":"2.6","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"3.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"30-day average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":".43","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".69","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":"1.05","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":"1.81","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":"2.38","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"3.98","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":"22.95","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"39.66","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Silver, total [as Ag]","parameter_code":"01077","statistic":"monthly average","qualifier":"<=","value":".24","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Silver, total [as Ag]","parameter_code":"01077","statistic":"monthly average","qualifier":"<=","value":".24","unit":"mg/L","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Silver, total [as Ag]","parameter_code":"01077","statistic":"daily maximum","qualifier":"<=","value":".43","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Silver, total [as Ag]","parameter_code":"01077","statistic":"daily maximum","qualifier":"<=","value":".43","unit":"mg/L","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Silver, total [as Ag]","parameter_code":"01077","statistic":"monthly average","qualifier":"<=","value":".66","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Silver, total [as Ag]","parameter_code":"01077","statistic":"monthly average","qualifier":"<=","value":".66","unit":"lb/d","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Silver, total [as Ag]","parameter_code":"01077","statistic":"daily maximum","qualifier":"<=","value":".97","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUL"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Silver, total [as Ag]","parameter_code":"01077","statistic":"daily maximum","qualifier":"<=","value":".97","unit":"lb/d","report_only":false,"enforceable":true,"months":["FEB"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"monthly average","qualifier":"<=","value":"1.48","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"2.61","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"monthly average","qualifier":"<=","value":"37.97","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"52.68","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"E. coli, thermotol, MF, MTEC","parameter_code":"31633","statistic":"daily maximum","qualifier":"<=","value":"77","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"annual average","qualifier":"<=","value":"8","unit":"MGD","report_only":false,"enforceable":true,"months":["DEC"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Organics, total toxic [TTO]","parameter_code":"78141","statistic":"daily maximum","qualifier":"<=","value":"1.37","unit":"mg/L","report_only":false,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Organics, total toxic [TTO]","parameter_code":"78141","statistic":"daily maximum","qualifier":"<=","value":"1.37","unit":"mg/L","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Organics, total toxic [TTO]","parameter_code":"78141","statistic":"daily maximum","qualifier":"<=","value":"1.37","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUL","AUG","SEP"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"001","parameter":"Organics, total toxic [TTO]","parameter_code":"78141","statistic":"daily maximum","qualifier":"<=","value":"1.37","unit":"mg/L","report_only":false,"enforceable":true,"months":["OCT","NOV","DEC"],"limit_set":"Sanitary and semi-conductor manufacturing wastewater"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":["JUL","AUG","SEP"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":["OCT","NOV","DEC"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":["JUL","AUG","SEP"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":["OCT","NOV","DEC"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"Ethylbenzene","parameter_code":"34371","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"Vinyl chloride","parameter_code":"39175","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"Trichloroethylene","parameter_code":"39180","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"Dichloroethene, total","parameter_code":"81328","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"},{"outfall":"007","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN"],"limit_set":"Stormwater runoff, underdrain discharges and intermittent non-contact cooling water"}],"next":[{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"copper","place":"US-VT","medium":"surface_water"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=copper&place=US-VT&medium=surface_water","url":"https://passage-data.com/api/v1/limits?parameter=copper&place=US-VT&medium=surface_water","page":"https://passage-data.com/limits/US-VT/copper"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"VT0000400"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=VT0000400"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"VT0000400"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=VT0000400"}]}