{"permit":"VI0080055","name":"Calabash Boom Housing","state":"VI","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/VI0080055"},"about":[{"label":"What it is","text":"Sewerage Systems (EPA's industry listing)"},{"label":"Where","text":"Coral Bay, St. John, the U.S. Virgin Islands","href":"https://www.openstreetmap.org/?mlat=18.3295&mlon=-64.7057666#map=14/18.3295/-64.7057666"},{"label":"Last 12 months","text":"Over a limit 4 times, last in June 2026 (Enterococci). 150 required values not reported. 16 of 20 reports filed late"},{"label":"Permit","text":"Expired Sep 30, 2021; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2021-04-03","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/VI0080055#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"VI","sic":"4952","permits":11,"list":"https://passage-data.com/api/v1/permits?state=VI&sic=4952"},"limits_from_version":null,"record":{"last_filed":"2026-06-30","over":4,"over_by":[["Enterococci",4]],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg C","report_only":true,"enforceable":true,"months":"all","limit_set":"Reverse Osmosis Brine"},{"outfall":"001","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"daily maximum","qualifier":"<=","value":"32","unit":"deg C","report_only":false,"enforceable":true,"months":"all","limit_set":"Reverse Osmosis Brine"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"7","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Reverse Osmosis Brine"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.3","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Reverse Osmosis Brine"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Reverse Osmosis Brine"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":".006","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Reverse Osmosis Brine"},{"outfall":"002","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg C","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"daily maximum","qualifier":"<=","value":"32","unit":"deg C","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"weekly average","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"7","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.3","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"weekly average","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":".0139","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Enterococci","parameter_code":"61211","statistic":"daily maximum","qualifier":"<=","value":"110","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Enterococci","parameter_code":"61211","statistic":"monthly geometric mean","qualifier":"<=","value":"30","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"BOD, 5-day, percent removal","parameter_code":"81010","statistic":"minimum","qualifier":">=","value":"85","unit":"%","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"},{"outfall":"002","parameter":"Solids, suspended percent removal","parameter_code":"81011","statistic":"minimum","qualifier":">=","value":"85","unit":"%","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Waste Water"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"VI","sic":"4952"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=VI&sic=4952","url":"https://passage-data.com/api/v1/permits?state=VI&sic=4952"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"VI0080055"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=VI0080055"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"VI0080055"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=VI0080055"}]}