{"permit":"TX0133604","name":"KIRBY INLAND MARINE, LP","state":"TX","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/TX0133604"},"about":[{"label":"What it is","text":"Marine Cargo Handling (EPA's industry listing)"},{"label":"Where","text":"Channelview, Texas","href":"https://www.openstreetmap.org/?mlat=29.758333&mlon=-95.096944#map=14/29.758333/-95.096944"},{"label":"Last 12 months","text":"No values over a limit. 1 of 11 reports filed late"},{"label":"Permit","text":"In force until Jul 10, 2031"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"TX","sic":"44","permits":19,"list":"https://passage-data.com/api/v1/permits?state=TX&sic=44","page":"https://passage-data.com/dmr/s/TX/44"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"upcoming":[{"parameter":"Cyanide, free [amenable to chlorination]","outfall":"013","limit":0.00878,"unit":"mg/L","statistic":"daily average","statistic_code":"DB","begin":"2029-08-01","kind":"new","now":null},{"parameter":"Cyanide, free [amenable to chlorination]","outfall":"013","limit":0.0186,"unit":"mg/L","statistic":"daily maximum","statistic_code":"DD","begin":"2029-08-01","kind":"new","now":{"median":0.0061,"n":9,"below_detection":1},"times_limit":0.328}],"limits":[{"outfall":"013","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily average","qualifier":"<=","value":"22","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"61","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"26","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"58","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":"<=","value":"16","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"36","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Cyanide, free [amenable to chlorination]","parameter_code":"00722","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".42","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".091","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".14","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":".311","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".51","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"},{"outfall":"013","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":"<=","value":".0013","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER - 013"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"TX","sic":"44"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=TX&sic=44","url":"https://passage-data.com/api/v1/permits?state=TX&sic=44","page":"https://passage-data.com/dmr/s/TX/44"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"TX0133604"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=TX0133604"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"TX0133604"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=TX0133604"}]}