{"permit":"TX0127779","name":"DALLAS 2100 ROSS LP","state":"TX","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/TX0127779"},"about":[{"label":"What it is","text":"Real Estate Investment Trusts (EPA's industry listing)"},{"label":"Where","text":"Dallas, Texas","href":"https://www.openstreetmap.org/?mlat=32.787289&mlon=-96.797169#map=14/32.787289/-96.797169"},{"label":"Last 12 months","text":"No values over a limit. 4 of 11 reports filed late"},{"label":"Permit","text":"In force until Sep 15, 2027"}],"renewal_due":null,"renewal_check":{"offered_because":"application_due_within_18_months","application_due":"2027-03-19","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/TX0127779#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":null,"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"daily average","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"trans-1,2-Dichloroethylene","parameter_code":"34546","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Vinyl chloride","parameter_code":"39175","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Trichloroethylene","parameter_code":"39180","statistic":"daily average","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Trichloroethylene","parameter_code":"39180","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":"<=","value":".0291","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":".0502","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"},{"outfall":"001","parameter":"cis-1,2-Dichloroethylene","parameter_code":"77093","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"GROUNDWATER - 001"}],"next":[{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"TX0127779"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=TX0127779"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"TX0127779"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=TX0127779"}]}