{"permit":"OK0034321","name":"Georgia-Pacific Muskogee LLC","state":"OK","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/OK0034321"},"about":[{"label":"What it is","text":"Paper Mills (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Muskogee, Oklahoma","href":"https://www.openstreetmap.org/?mlat=35.731944&mlon=-95.295556#map=14/35.731944/-95.295556"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"Expired Jun 30, 2026; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2026-01-01","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/OK0034321#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"OK","sic":"26","permits":5,"list":"https://passage-data.com/api/v1/permits?state=OK&sic=26","page":"https://passage-data.com/dmr/s/OK/26"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"92","unit":"mg/L","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"175","unit":"mg/L","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"14065","unit":"lb/d","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"26702","unit":"lb/d","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"125","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"234","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"19042","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"35797","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":"<=","value":"73","unit":"mg/L","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"175","unit":"mg/L","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":"<=","value":"543","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":"<=","value":"11153","unit":"lb/d","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"815","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"26738","unit":"lb/d","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"BOD, carbonaceous [5 day, 20 C]","parameter_code":"80082","statistic":"monthly average","qualifier":"<=","value":"67","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"BOD, carbonaceous [5 day, 20 C]","parameter_code":"80082","statistic":"daily maximum","qualifier":"<=","value":"100.5","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"BOD, carbonaceous [5 day, 20 C]","parameter_code":"80082","statistic":"monthly average","qualifier":"<=","value":"9096","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Treated Wastewater"},{"outfall":"001","parameter":"BOD, carbonaceous [5 day, 20 C]","parameter_code":"80082","statistic":"daily maximum","qualifier":"<=","value":"13645","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"Treated Wastewater"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"004","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"004","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"55","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"TX1","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"LC50 Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TAM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TAM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"LC50 Pass/Fail Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TIM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TIM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"%Mortality Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TJM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"},{"outfall":"TX1","parameter":"% Mortality Static Renewal 48 Hr Pimephales promelas or use TJA6C","parameter_code":"TJM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"OK","sic":"26"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=OK&sic=26","url":"https://passage-data.com/api/v1/permits?state=OK&sic=26","page":"https://passage-data.com/dmr/s/OK/26"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"OK0034321"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=OK0034321"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"OK0034321"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=OK0034321"}]}