{"permit":"OK0000442","name":"OG&E-Horseshoe Lake","state":"OK","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/OK0000442"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Harrah, Oklahoma","href":"https://www.openstreetmap.org/?mlat=35.430612&mlon=-97.181479#map=14/35.430612/-97.181479"},{"label":"Last 12 months","text":"No values over a limit. 33 required values not reported. 11 of 105 reports filed late"},{"label":"Permit","text":"In force until Feb 28, 2027"}],"renewal_due":{"date":"2026-09-01","when":"Sep 1, 2026, overdue","urgent":true},"renewal_check":{"offered_because":"application_overdue","application_due":"2026-09-01","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/OK0000442#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"OK","sic":"4911","permits":25,"list":"https://passage-data.com/api/v1/permits?state=OK&sic=4911","page":"https://passage-data.com/dmr/s/OK/4911"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg C","report_only":true,"enforceable":true,"months":["MAY","JUN","JUL","AUG","SEP"],"limit_set":"Cooling Pond Discharge"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Pond Discharge"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9.6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Pond Discharge"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Pond Discharge"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Pond Discharge"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"33.78","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"112.59","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"monthly average","qualifier":"<=","value":"16.89","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"daily maximum","qualifier":"<=","value":"22.52","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 8 Cooling Tower Blowdown"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 8 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 8 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 8 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":"<=","value":".099","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 8 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"monthly average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Yearly Monitoring FAC"},{"outfall":"003","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Yearly Monitoring FAC"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"18.01","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"60.05","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"monthly average","qualifier":"<=","value":"9.01","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Oil and grease, hexane extr method","parameter_code":"00552","statistic":"daily maximum","qualifier":"<=","value":"12.01","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"monthly average","qualifier":"<=","value":"31.8","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"daily maximum","qualifier":"<=","value":"55.2","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"monthly average","qualifier":"<=","value":".019","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"daily maximum","qualifier":"<=","value":".033","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume Wastes"},{"outfall":"009","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Water -Units 6 & 7"},{"outfall":"009","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Water -Units 6 & 7"},{"outfall":"009","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Water -Units 6 & 7"},{"outfall":"009","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Water -Units 6 & 7"},{"outfall":"009","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Water -Units 6 & 7"},{"outfall":"009","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Water -Units 6 & 7"},{"outfall":"009","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":"<=","value":".099","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Water -Units 6 & 7"},{"outfall":"009","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"monthly average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Yearly Monitoring FAC"},{"outfall":"009","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Yearly Monitoring FAC"},{"outfall":"012","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg C","report_only":true,"enforceable":true,"months":["MAY","JUN","JUL","AUG","SEP"],"limit_set":"Emergency discharge"},{"outfall":"012","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Emergency discharge"},{"outfall":"012","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9.6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Emergency discharge"},{"outfall":"012","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Emergency discharge"},{"outfall":"012","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Emergency discharge"},{"outfall":"IF01","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Intake 01"},{"outfall":"IF02","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Intake 02"},{"outfall":"TX3","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"LC50 Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TAM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"LC50 Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TAM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TAM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TAM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"LC50 Pass/Fail Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TIM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"LC50 Pass/Fail Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TIM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TIM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TIM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"%Mortality Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TJM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"%Mortality Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TJM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"% Mortality Static Renewal 48 Hr Pimephales promelas or use TJA6C","parameter_code":"TJM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX3","parameter":"% Mortality Static Renewal 48 Hr Pimephales promelas or use TJA6C","parameter_code":"TJM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"LC50 Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TAM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"LC50 Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TAM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TAM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TAM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"LC50 Pass/Fail Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TIM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"LC50 Pass/Fail Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TIM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TIM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"LC50 Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TIM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"%Mortality Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TJM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"%Mortality Static Renewal 48Hr Acute Daphnia Pulex","parameter_code":"TJM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"% Mortality Static Renewal 48 Hr Pimephales promelas or use TJA6C","parameter_code":"TJM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"},{"outfall":"TX9","parameter":"% Mortality Static Renewal 48 Hr Pimephales promelas or use TJA6C","parameter_code":"TJM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Semi-annual biomonitoring testing"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"OK","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=OK&sic=4911","url":"https://passage-data.com/api/v1/permits?state=OK&sic=4911","page":"https://passage-data.com/dmr/s/OK/4911"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"OK0000442"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=OK0000442"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"OK0000442"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=OK0000442"}]}