{"permit":"OH0142476","name":"City of Delaware","state":"OH","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/OH0142476"},"about":[{"label":"What it is","text":"Water Supply (EPA's industry listing)"},{"label":"Where","text":"Delaware, Ohio","href":"https://www.openstreetmap.org/?mlat=40.3416667&mlon=-83.0691667#map=14/40.3416667/-83.0691667"},{"label":"Last 12 months","text":"Over a limit 3 times, last in July 2026 (Strontium, total recoverable, ug/L; Solids, total suspended)"},{"label":"Permit","text":"In force until Nov 30, 2027"}],"renewal_due":null,"renewal_check":{"offered_because":"application_due_within_18_months","application_due":"2027-06-03","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/OH0142476#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"OH","sic":"4941","permits":147,"list":"https://passage-data.com/api/v1/permits?state=OH&sic=4941","page":"https://passage-data.com/dmr/s/OH/4941"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":3,"over_by":[["Strontium, total recoverable, ug/L",2],["Solids, total suspended",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Solids, total suspended","times":1,"find_limits":{"parameter":"total suspended solids","place":"US-OH","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-OH&medium=water_discharge"}],"limits":[{"outfall":"001","parameter":"Oxygen, dissolved [DO]","parameter_code":"00300","statistic":"daily minimum","qualifier":">=","value":"7","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"12","unit":"mg/L","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","DEC"],"limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"12","unit":"mg/L","report_only":false,"enforceable":true,"months":["APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV"],"limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"18","unit":"mg/L","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","DEC"],"limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"18","unit":"mg/L","report_only":false,"enforceable":true,"months":["APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV"],"limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"78.6","unit":"kg/d","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","DEC"],"limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"78.6","unit":"kg/d","report_only":false,"enforceable":true,"months":["APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV"],"limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"118","unit":"kg/d","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","DEC"],"limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"118","unit":"kg/d","report_only":false,"enforceable":true,"months":["APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV"],"limit_set":null},{"outfall":"001","parameter":"Iron, suspended","parameter_code":"01044","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","DEC"],"limit_set":null},{"outfall":"001","parameter":"Iron, suspended","parameter_code":"01044","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV"],"limit_set":null},{"outfall":"001","parameter":"Iron, suspended","parameter_code":"01044","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","DEC"],"limit_set":null},{"outfall":"001","parameter":"Iron, suspended","parameter_code":"01044","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV"],"limit_set":null},{"outfall":"001","parameter":"Manganese, suspended","parameter_code":"01054","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV"],"limit_set":null},{"outfall":"001","parameter":"Manganese, suspended","parameter_code":"01054","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","DEC"],"limit_set":null},{"outfall":"001","parameter":"Manganese, suspended","parameter_code":"01054","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV"],"limit_set":null},{"outfall":"001","parameter":"Manganese, suspended","parameter_code":"01054","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","DEC"],"limit_set":null},{"outfall":"001","parameter":"Dichlorobromomethane","parameter_code":"32101","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Dichlorobromomethane","parameter_code":"32101","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Bromoform","parameter_code":"32104","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Bromoform","parameter_code":"32104","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Dibromochloromethane","parameter_code":"32105","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Dibromochloromethane","parameter_code":"32105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Chloroform","parameter_code":"32106","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Chloroform","parameter_code":"32106","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Methyl bromide [Bromomethane]","parameter_code":"34413","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Methyl bromide [Bromomethane]","parameter_code":"34413","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Methyl chloride [Chloromethane]","parameter_code":"34418","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Methyl chloride [Chloromethane]","parameter_code":"34418","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Methylene chloride","parameter_code":"34423","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Methylene chloride","parameter_code":"34423","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["SEP"],"limit_set":null},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":".038","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Toxicity [acute], Ceriodaphnia dubia","parameter_code":"61425","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"tox acute","report_only":false,"enforceable":true,"months":["MAR","JUN","AUG","DEC"],"limit_set":null},{"outfall":"020","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"37","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"020","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"3082","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"75","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"021","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"6164","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"112","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"022","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"9247","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"150","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"023","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"12329","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"187","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"024","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"15411","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"225","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"025","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"18494","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"026","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"263","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"026","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"026","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"026","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"21576","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"027","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"300","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"027","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"027","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"027","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"24658","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"028","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"375","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"028","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"028","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"028","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"30823","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"029","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"451","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"029","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"029","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"029","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"36988","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"030","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"526","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"030","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"030","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"030","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"43152","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"031","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"601","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"031","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"031","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"031","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"49317","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"032","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"601","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"032","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"032","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"032","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"55482","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"033","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"601","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"033","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"033","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"033","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"61647","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"034","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"601","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"034","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"034","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"034","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"67811","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"035","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"601","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"035","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"035","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"035","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"73976","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"036","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"601","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"036","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"036","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"036","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"86305","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"037","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":"<=","value":"601","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"037","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"037","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"037","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":"<=","value":"98635","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"800","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"800","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"801","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["MAR","JUN","AUG","DEC"],"limit_set":null},{"outfall":"801","parameter":"Strontium, total recoverable, ug/L","parameter_code":"01084","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":["MAR","JUN","AUG","DEC"],"limit_set":null},{"outfall":"801","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"801","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"801","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"801","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"801","parameter":"%Effect Static Renewal 48Hr Acute Ceriodaphnia dubia","parameter_code":"TCM3B","statistic":"monthly average","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":["MAR","JUN","AUG","DEC"],"limit_set":null},{"outfall":"801","parameter":"%Effect Static Renewal 48Hr Acute Ceriodaphnia dubia","parameter_code":"TCM3B","statistic":"daily maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":["MAR","JUN","AUG","DEC"],"limit_set":null},{"outfall":"901","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"901","parameter":"Solids, total dissolved- 180 deg. C","parameter_code":"70300","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"OH","sic":"4941"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=OH&sic=4941","url":"https://passage-data.com/api/v1/permits?state=OH&sic=4941","page":"https://passage-data.com/dmr/s/OH/4941"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"total suspended solids","place":"US-OH","medium":"water_discharge"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-OH&medium=water_discharge","url":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-OH&medium=water_discharge","page":"https://passage-data.com/limits/US-OH/total-suspended-solids"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"OH0142476"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=OH0142476"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"OH0142476"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=OH0142476"}]}