{"permit":"NY0201243","name":"CONSOLIDATED EDISON OF NY","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0201243"},"about":[{"label":"What it is","text":"Combination Utilities (EPA's industry listing)"},{"label":"Where","text":"Astoria, New York","href":"https://www.openstreetmap.org/?mlat=40.784722&mlon=-73.911944#map=14/40.784722/-73.911944"},{"label":"Last 12 months","text":"No values over a limit. 3 of 28 reports filed late"},{"label":"Permit","text":"In force until Jan 31, 2027"}],"renewal_due":{"date":"2026-08-04","when":"Aug 4, 2026, overdue","urgent":true},"renewal_check":{"offered_because":"application_overdue","application_due":"2026-08-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/NY0201243#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"NY","sic":"4939","permits":11,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=4939","page":"https://passage-data.com/dmr/s/NY/4939"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (QUARTERLY)"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"ACTION LEVELS TYPE I (MONTHLY)"},{"outfall":"001","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (QUARTERLY)"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Vanadium, total [as V]","parameter_code":"01087","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (QUARTERLY)"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"},{"outfall":"001","parameter":"Toluene","parameter_code":"34010","statistic":"daily maximum","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"ACTION LEVELS TYPE I (MONTHLY)"},{"outfall":"001","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"ACTION LEVELS TYPE I (MONTHLY)"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"ACTION LEVELS TYPE I (MONTHLY)"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":"1.15","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER (MONTHLY)"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"4939"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=4939","url":"https://passage-data.com/api/v1/permits?state=NY&sic=4939","page":"https://passage-data.com/dmr/s/NY/4939"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0201243"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0201243"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0201243"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0201243"}]}