{"permit":"NY0098817","name":"SIMMSMETAL EAST LLC","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0098817"},"about":[{"label":"What it is","text":"Primary Metal Products (EPA's industry listing)"},{"label":"Where","text":"North Chili, New York","href":"https://www.openstreetmap.org/?mlat=43.106917&mlon=-77.792833#map=14/43.106917/-77.792833"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"Expired Apr 30, 2025; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2024-11-01","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/NY0098817#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"NY","sic":"33","permits":19,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=33","page":"https://passage-data.com/dmr/s/NY/33"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"001","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF -QUARTERLYS"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF -QUARTERLYS"},{"outfall":"001","parameter":"Aluminum, total recoverable","parameter_code":"01104","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Aluminum, total recoverable","parameter_code":"01104","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Benzene, ethylbenzene, toluene, xylene combination","parameter_code":"30383","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Benzene, ethylbenzene, toluene, xylene combination","parameter_code":"30383","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Toluene","parameter_code":"34010","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Toluene","parameter_code":"34010","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Ethylbenzene","parameter_code":"34371","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Ethylbenzene","parameter_code":"34371","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Nitrogen, ammonia, total [as NH3]","parameter_code":"34726","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"001","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Mercury, total recoverable","parameter_code":"71901","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Mercury, total recoverable","parameter_code":"71901","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF"},{"outfall":"001","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"001","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"STORM WATER RUNOFF/ACTION LVLS"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"BYPASS"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"BYPASS"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"BYPASS"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"BYPASS"},{"outfall":"003","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"33"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=33","url":"https://passage-data.com/api/v1/permits?state=NY&sic=33","page":"https://passage-data.com/dmr/s/NY/33"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0098817"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0098817"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0098817"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0098817"}]}