{"permit":"NY0072231","name":"HADCO CORP","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0072231"},"about":[{"label":"What it is","text":"Metal Coating And Allied Services (EPA's industry listing)"},{"label":"Where","text":"Owego, New York","href":"https://www.openstreetmap.org/?mlat=42.103667&mlon=-76.228083#map=14/42.103667/-76.228083"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Sep 30, 2030"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"NY","sic":"34","permits":11,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=34","page":"https://passage-data.com/dmr/s/NY/34"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"daily maximum","qualifier":"<=","value":".57","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"3.6","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".36","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"4.67","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Tin, total [as Sn]","parameter_code":"01102","statistic":"daily maximum","qualifier":"<=","value":"2.35","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"001","parameter":"Gold, total [as Au]","parameter_code":"71910","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"OUTFALL 001 S/A ACTION LEVELS"},{"outfall":"001","parameter":"BOD, carbonaceous [5 day, 20 C]","parameter_code":"80082","statistic":"daily maximum","qualifier":"<=","value":"144","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & NON-CONTACT COOLING"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM RUNOFF"},{"outfall":"01A","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"REVERSE OSMOSIS REJECT WATER"},{"outfall":"01A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"REVERSE OSMOSIS REJECT WATER"},{"outfall":"01A","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"REVERSE OSMOSIS REJECT WATER"},{"outfall":"01B","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Toluene","parameter_code":"34010","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Methylene chloride","parameter_code":"34423","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"1,1,1-Trichloroethane","parameter_code":"34506","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Trichloroethylene","parameter_code":"39180","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"1,1-Dichloroethene","parameter_code":"61162","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"},{"outfall":"01B","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"GROUNDWATER REMEDIATION WASTE"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"34"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=34","url":"https://passage-data.com/api/v1/permits?state=NY&sic=34","page":"https://passage-data.com/dmr/s/NY/34"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0072231"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0072231"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0072231"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0072231"}]}