{"permit":"NY0008231","name":"ROSETON GENERATING LLC","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0008231"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Newburgh, New York","href":"https://www.openstreetmap.org/?mlat=41.570278&mlon=-73.980389#map=14/41.570278/-73.980389"},{"label":"Last 12 months","text":"Over a limit 2 times, last in January 2026 (Iron, total [as Fe]; Solids, settleable)"},{"label":"Permit","text":"Expired May 31, 2024; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2023-12-03","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/NY0008231#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"NY","sic":"4911","permits":39,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","page":"https://passage-data.com/dmr/s/NY/4911"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":2,"over_by":[["Iron, total [as Fe]",1],["Solids, settleable",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Iron, total [as Fe]","times":1,"find_limits":{"parameter":"iron","place":"US-NY","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=iron&place=US-NY&medium=surface_water"}],"limits":[{"outfall":"002","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"99","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Temp. diff. between samp. & upstrm deg. F","parameter_code":"00018","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Temp. diff. between samp. & upstrm deg. F","parameter_code":"00018","statistic":"daily maximum","qualifier":"<=","value":"36","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Waste heat rejection rate","parameter_code":"00179","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/hr","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Flow rate","parameter_code":"74060","statistic":"monthly average","qualifier":null,"value":null,"unit":"Mgal/hr","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Flow rate","parameter_code":"74060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"Mgal/hr","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"UNDERGROUND PUMP HOUSE"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM INTAKE"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"UNDERGROUND PUMP HOUSE"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM INTAKE"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"UNDERGROUND PUMP HOUSE"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM INTAKE"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"UNDERGROUND PUMP HOUSE"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM INTAKE"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"UNDERGROUND PUMP HOUSE"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM INTAKE"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"OIL TANK STORAGE RUNOFF"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"UNDERGROUND PUMP HOUSE"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM INTAKE"},{"outfall":"003","parameter":"Toluene","parameter_code":"34010","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"OIL TANK STORAGE AREA QUARTERLY"},{"outfall":"003","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"OIL TANK STORAGE AREA QUARTERLY"},{"outfall":"003","parameter":"Ethylbenzene","parameter_code":"34371","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"OIL TANK STORAGE AREA QUARTERLY"},{"outfall":"003","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"OIL TANK STORAGE AREA QUARTERLY"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily average","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"monthly average","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily average","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".16","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":".7","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":".3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Vanadium, total [as V]","parameter_code":"01087","statistic":"daily average","qualifier":"<=","value":"12","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Vanadium, total [as V]","parameter_code":"01087","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Vanadium, total [as V]","parameter_code":"01087","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Vanadium, total [as V]","parameter_code":"01087","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Vanadium, total [as V]","parameter_code":"01087","statistic":"daily maximum","qualifier":"<=","value":"2.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(PROCESS WASTE"},{"outfall":"004","parameter":"EDTA","parameter_code":"78151","statistic":"daily maximum","qualifier":"<=","value":".28","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly maximum","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"004","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly maximum","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TRTMT FAC.(COMBINED)"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"DRAINAGE"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"DRAINAGE"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"DRAINAGE"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DRAINAGE"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DRAINAGE"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"DRAINAGE"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DRAINAGE"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DRAINAGE"},{"outfall":"006","parameter":"Flow rate","parameter_code":"00056","statistic":"30-day arithmetic mean","qualifier":"<=","value":"12000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Flow rate","parameter_code":"00056","statistic":"30-day arithmetic mean","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"7-day average","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"7-day average","qualifier":"<=","value":"4.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"7-day average","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"7-day average","qualifier":"<=","value":"4.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"minimum","qualifier":">=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"30-day geometric mean","qualifier":"<=","value":"200","unit":"MPN/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"7-day geometric mean","qualifier":"<=","value":"400","unit":"MPN/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"BOD, 5-day, percent removal","parameter_code":"81010","statistic":"monthly average minimum","qualifier":">=","value":"85","unit":"%","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"006","parameter":"Solids, suspended percent removal","parameter_code":"81011","statistic":"monthly average minimum","qualifier":">=","value":"85","unit":"%","report_only":false,"enforceable":true,"months":"all","limit_set":"SEWAGE TREATMENT PLANT"},{"outfall":"013","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PLANT DRAINAGE"},{"outfall":"013","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PLANT DRAINAGE"},{"outfall":"013","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PLANT DRAINAGE"},{"outfall":"013","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PLANT DRAINAGE"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","url":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","page":"https://passage-data.com/dmr/s/NY/4911"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"iron","place":"US-NY","medium":"surface_water"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=iron&place=US-NY&medium=surface_water","url":"https://passage-data.com/api/v1/limits?parameter=iron&place=US-NY&medium=surface_water","page":"https://passage-data.com/limits/US-NY/iron"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0008231"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0008231"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0008231"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0008231"}]}