{"permit":"NY0007129","name":"SPECIAL METALS LLC","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0007129"},"about":[{"label":"What it is","text":"Secondary Nonferrous Metals (EPA's industry listing)"},{"label":"Where","text":"New Hartford, New York","href":"https://www.openstreetmap.org/?mlat=43.078278&mlon=-75.341556#map=14/43.078278/-75.341556"},{"label":"Last 12 months","text":"Over a limit 4 times, last in May 2026 (Nickel, total [as Ni]; Cobalt, total [as Co]; Copper, total [as Cu]). 31 required values not reported. 7 of 33 reports filed late"},{"label":"Permit","text":"In force until Aug 31, 2031"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"NY","sic":"33","permits":19,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=33","page":"https://passage-data.com/dmr/s/NY/33"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":4,"over_by":[["Nickel, total [as Ni]",1],["Cobalt, total [as Co]",1],["Copper, total [as Cu]",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Nickel, total [as Ni]","times":1,"find_limits":{"parameter":"nickel","place":"US-NY","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=nickel&place=US-NY&medium=surface_water"},{"parameter":"Cobalt, total [as Co]","times":1,"find_limits":{"parameter":"cobalt","place":"US-NY","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=cobalt&place=US-NY&medium=surface_water"},{"parameter":"Copper, total [as Cu]","times":1,"find_limits":{"parameter":"copper","place":"US-NY","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=copper&place=US-NY&medium=surface_water"}],"limits":[{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Cyanide, free [amenable to chlorination]","parameter_code":"00722","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Cyanide, free [amenable to chlorination]","parameter_code":"00722","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"daily maximum","qualifier":"<=","value":"4.46","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Cobalt, total [as Co]","parameter_code":"01037","statistic":"daily maximum","qualifier":"<=","value":"5","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Cobalt, total [as Co]","parameter_code":"01037","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"18","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":"9.12","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":".3","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"104","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":"<=","value":"2.5","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"PCB-1221","parameter_code":"39488","statistic":"daily maximum","qualifier":"<=","value":".095","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"PCB-1221","parameter_code":"39488","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"PCB-1242","parameter_code":"39496","statistic":"daily maximum","qualifier":"<=","value":".095","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"PCB-1242","parameter_code":"39496","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"PCB-1248","parameter_code":"39500","statistic":"daily maximum","qualifier":"<=","value":".095","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"PCB-1248","parameter_code":"39500","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"PCB-1254","parameter_code":"39504","statistic":"daily maximum","qualifier":"<=","value":".095","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"PCB-1254","parameter_code":"39504","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Number of Events","parameter_code":"51484","statistic":"monthly average","qualifier":null,"value":null,"unit":"#","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"001","parameter":"Toxicity [acute], Ceriodaphnia dubia","parameter_code":"61425","statistic":"maximum","qualifier":"<=","value":".3","unit":"tox acute","report_only":false,"enforceable":false,"months":"all","limit_set":"WET TESTING"},{"outfall":"001","parameter":"Toxicity [chronic], Ceriodaphnia dubia","parameter_code":"61426","statistic":"maximum","qualifier":"<=","value":"1","unit":"tox chronic","report_only":false,"enforceable":true,"months":"all","limit_set":"WET TESTING"},{"outfall":"001","parameter":"Toxicity [acute], Pimephales promelas [Fathead Minnow]","parameter_code":"61427","statistic":"maximum","qualifier":"<=","value":".3","unit":"tox acute","report_only":false,"enforceable":false,"months":"all","limit_set":"WET TESTING"},{"outfall":"001","parameter":"Toxicity [chronic], Pimephales promelas [Fathead Minnow]","parameter_code":"61428","statistic":"maximum","qualifier":"<=","value":"1","unit":"tox chronic","report_only":false,"enforceable":false,"months":"all","limit_set":"WET TESTING"},{"outfall":"001","parameter":"Overflow volume [SS0 volume, CSO volume]","parameter_code":"74063","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER&SBSW"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM SW OF FACILITY"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM SW OF FACILITY"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM SW OF FACILITY"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM SW OF FACILITY"},{"outfall":"002","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM SW OF FACILITY"},{"outfall":"002","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF FROM SW OF FACILITY"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"003","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"003","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"003","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"003","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER RUNOFF STORAGE AREA"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"004","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"005","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"},{"outfall":"005","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM WATER RUNOFF"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"33"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=33","url":"https://passage-data.com/api/v1/permits?state=NY&sic=33","page":"https://passage-data.com/dmr/s/NY/33"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"nickel","place":"US-NY","medium":"surface_water"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=nickel&place=US-NY&medium=surface_water","url":"https://passage-data.com/api/v1/limits?parameter=nickel&place=US-NY&medium=surface_water","page":"https://passage-data.com/limits/US-NY/nickel"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0007129"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0007129"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0007129"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0007129"}]}