{"permit":"NY0005126","name":"CONSOLIDATED EDISON CO OF NY, INC","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0005126"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Manhattan (Subdivision), New York","href":"https://www.openstreetmap.org/?mlat=40.727639&mlon=-73.97275#map=14/40.727639/-73.97275"},{"label":"Last 12 months","text":"Over a limit once, last in March 2026 (Oil & Grease)"},{"label":"Permit","text":"Expired Nov 30, 2019; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2019-06-03","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/NY0005126#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"NY","sic":"4911","permits":39,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","page":"https://passage-data.com/dmr/s/NY/4911"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":1,"over_by":[["Oil & Grease",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Oil & Grease","times":1,"find_limits":{"parameter":"oil grease","place":"US-NY","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=oil+grease&place=US-NY&medium=water_discharge"}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"98","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"Net rate of additionof heat","parameter_code":"61575","statistic":"daily maximum","qualifier":"<=","value":"2.46","unit":"GBTU/hr","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"daily maximum","qualifier":"<=","value":"18","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED DISCHARGE"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"CONVEYOR TUNNEL SUMP"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"CONVEYOR TUNNEL SUMP"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"CONVEYOR TUNNEL SUMP - QUARTERLY"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"003","parameter":"Toluene","parameter_code":"34010","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"003","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"003","parameter":"Ethylbenzene","parameter_code":"34371","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"003","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"003","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSATE FROM STUYVESAN TOWN/PETER COOPER VILLAGE (MONTHLY)"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSATE FROM STUYVESAN TOWN/PETER COOPER VILLAGE (MONTHLY)"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSATE FROM STUYVESAN TOWN/PETER COOPER VILLAGE (MONTHLY)"},{"outfall":"01A","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"BOILER BLOWDOWN (MONTHLY)"},{"outfall":"01A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"BOILER BLOWDOWN (MONTHLY)"},{"outfall":"01A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"BOILER BLOWDOWN (MONTHLY)"},{"outfall":"01A","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"BOILER BLOWDN (QUARTERLY)"},{"outfall":"01B","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NEUTRALIZATION TK (MONTHLY)"},{"outfall":"01B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NEUTRALIZATION TK (MONTHLY)"},{"outfall":"01B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NEUTRALIZATION TK (MONTHLY)"},{"outfall":"01B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"NEUTRALIZATION TK (QTRLY)"},{"outfall":"01C","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"S STREAM & GENERATING STATIONS OIL/WATER SEPERATOR"},{"outfall":"01C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"S STREAM & GENERATING STATIONS OIL/WATER SEPERATOR"},{"outfall":"01C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"S STREAM & GENERATING STATIONS OIL/WATER SEPERATOR"},{"outfall":"01C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"S STREAM & GENERATING STATIONS OIL/WATER SEPERATOR"},{"outfall":"01D","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"DEMINERALIZED WATER TREATMENT PLANT SETTLING TANK MONTHLY"},{"outfall":"01D","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DEMINERALIZED WATER TREATMENT PLANT SETTLING TANK MONTHLY"},{"outfall":"01D","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DEMINERALIZED WATER TREATMENT PLANT SETTLING TANK MONTHLY"},{"outfall":"01D","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DEMINERALIZED WATER TREATMENT PLANT SETTLING TANK  (QTRLY)"},{"outfall":"01E","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"TK FARM OIL/WTR SEPR (MONTHLY)"},{"outfall":"01E","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TK FARM OIL/WTR SEPR (MONTHLY)"},{"outfall":"01E","parameter":"Toluene","parameter_code":"34010","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"TANK FARM OIL/WATER SEPAR. DIS"},{"outfall":"01E","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"TANK FARM OIL/WATER SEPAR. DIS"},{"outfall":"01E","parameter":"Ethylbenzene","parameter_code":"34371","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"TANK FARM OIL/WATER SEPAR. DIS"},{"outfall":"01E","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"TANK FARM OIL/WATER SEPAR. DIS"},{"outfall":"01F","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"REV OSMOSIS (MONTHLY)"},{"outfall":"01F","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"REV OSMOSIS (MONTHLY)"},{"outfall":"01F","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"REV OSMOSIS (MONTHLY)"},{"outfall":"01F","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"REV OSMOSIS REJ (QTRLY)"},{"outfall":"01G","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"AUTO PULSE FLTR BKWSH (MNTHLY)"},{"outfall":"01G","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"AUTO PULSE FLTR BKWSH (MNTHLY)"},{"outfall":"01G","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"AUTO PULSE FLTR BKWSH (MNTHLY)"},{"outfall":"01G","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"AUTO PULSE FLTR BKWSH (QUARTERLY)"},{"outfall":"01H","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"BOILER BLOWDOWN (MONTHLY)"},{"outfall":"01H","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"BOILER BLOWDOWN (MONTHLY)"},{"outfall":"01H","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"BOILER BLOWDOWN (MONTHLY)"},{"outfall":"01H","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"BOILER BLOWDN (QUARTERLY)"},{"outfall":"04A","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"FIRE SYSTEM TEST WATER (QUARTERLY)"},{"outfall":"04A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"FIRE SYSTEM TEST WATER (QUARTERLY)"},{"outfall":"04A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"FIRE SYSTEM TEST WATER (QUARTERLY)"},{"outfall":"04A","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"FIRE SYSTEM TEST WATER (QUARTERLY)"},{"outfall":"04A","parameter":"PCB-1254","parameter_code":"39504","statistic":"monthly average","qualifier":null,"value":null,"unit":"ng/L","report_only":true,"enforceable":true,"months":"all","limit_set":"FIRE SYATEM TEST WATER PCB'S"},{"outfall":"04A","parameter":"PCB-1254","parameter_code":"39504","statistic":"daily maximum","qualifier":"<=","value":"200","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"FIRE SYATEM TEST WATER PCB'S"},{"outfall":"04A","parameter":"PCB-1260","parameter_code":"39508","statistic":"monthly average","qualifier":null,"value":null,"unit":"ng/L","report_only":true,"enforceable":true,"months":"all","limit_set":"FIRE SYATEM TEST WATER PCB'S"},{"outfall":"04A","parameter":"PCB-1260","parameter_code":"39508","statistic":"daily maximum","qualifier":"<=","value":"200","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"FIRE SYATEM TEST WATER PCB'S"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","url":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","page":"https://passage-data.com/dmr/s/NY/4911"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"oil grease","place":"US-NY","medium":"water_discharge"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=oil+grease&place=US-NY&medium=water_discharge","url":"https://passage-data.com/api/v1/limits?parameter=oil+grease&place=US-NY&medium=water_discharge","page":"https://passage-data.com/limits/US-NY/oil-grease"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0005126"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0005126"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0005126"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0005126"}]}