{"permit":"NY0003395","name":"TITANX ENGINE COOLING, INC","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0003395"},"about":[{"label":"What it is","text":"Motor Vehicle Parts And Accessories (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Jamestown, New York","href":"https://www.openstreetmap.org/?mlat=42.109861&mlon=-79.2065#map=14/42.109861/-79.2065"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"Expired Oct 31, 2018; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2018-05-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/NY0003395#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"NY","sic":"37","permits":6,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=37","page":"https://passage-data.com/dmr/s/NY/37"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"28.6","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"1.2","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"1.8","unit":"mg/L","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"24","unit":"lb/d","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP","OCT"],"limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"37","unit":"lb/d","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","NOV","DEC"],"limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"18.3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"daily maximum","qualifier":"<=","value":"55","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1.94","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"18.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".89","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"3.82","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":"<=","value":"9.1","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Cesium, total [as Cs]","parameter_code":"01117","statistic":"daily maximum","qualifier":"<=","value":".31","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Lithium, total [as Li]","parameter_code":"01132","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Surfactants [MBAS]","parameter_code":"38260","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Surfactants [MBAS]","parameter_code":"38260","statistic":"daily maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Toxicity [acute], Ceriodaphnia dubia","parameter_code":"61425","statistic":"maximum","qualifier":"<=","value":"2.6","unit":"tox acute","report_only":false,"enforceable":false,"months":"all","limit_set":"WET TESTING ACTION LEVELS"},{"outfall":"001","parameter":"Toxicity [chronic], Ceriodaphnia dubia","parameter_code":"61426","statistic":"maximum","qualifier":"<=","value":"16","unit":"tox chronic","report_only":false,"enforceable":false,"months":"all","limit_set":"WET TESTING ACTION LEVELS"},{"outfall":"001","parameter":"Toxicity [acute], Pimephales promelas [Fathead Minnow]","parameter_code":"61427","statistic":"maximum","qualifier":"<=","value":"2.6","unit":"tox acute","report_only":false,"enforceable":false,"months":"all","limit_set":"WET TESTING ACTION LEVELS"},{"outfall":"001","parameter":"Toxicity [chronic], Pimephales promelas [Fathead Minnow]","parameter_code":"61428","statistic":"maximum","qualifier":"<=","value":"16","unit":"tox chronic","report_only":false,"enforceable":false,"months":"all","limit_set":"WET TESTING ACTION LEVELS"},{"outfall":"001","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":"<=","value":"200","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":"<=","value":"200","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY SAMPLING- MERCURY"},{"outfall":"001","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY SAMPLING- MERCURY"},{"outfall":"001","parameter":"Flow","parameter_code":"74076","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Flow, process wastewater","parameter_code":"78886","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Flow, total","parameter_code":"82220","statistic":"monthly average","qualifier":"<=","value":"1","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"001","parameter":"Flow, total","parameter_code":"82220","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS & CONTACT COOLING"},{"outfall":"002","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"EMERGENCY OVRFLOW CONTACT COOL"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"EMERGENCY OVRFLOW CONTACT COOL"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"EMERGENCY OVRFLOW CONTACT COOL"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"EMERGENCY OVRFLOW CONTACT COOL"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"EMERGENCY OVRFLOW CONTACT COOL"},{"outfall":"003","parameter":"Surfactants [MBAS]","parameter_code":"38260","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"EMERGENCY OVRFLOW CONTACT COOL"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"37"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=37","url":"https://passage-data.com/api/v1/permits?state=NY&sic=37","page":"https://passage-data.com/dmr/s/NY/37"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0003395"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0003395"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0003395"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0003395"}]}