{"permit":"NY0002321","name":"NRG DUNKIRK POWER LLC","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0002321"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Dunkirk, New York","href":"https://www.openstreetmap.org/?mlat=42.4915&mlon=-79.346667#map=14/42.4915/-79.346667"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"Expired Apr 30, 2015; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2014-11-01","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/NY0002321#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"NY","sic":"4911","permits":39,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","page":"https://passage-data.com/dmr/s/NY/4911"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"95","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"95","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"COND COOLING / ROOF / FLOOR DRAINS"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".005","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"COND COOLING / ROOF / FLOOR DRAINS"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".03","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"COND COOLING / ROOF / FLOOR DRAINS"},{"outfall":"001","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"daily maximum","qualifier":"<=","value":".004","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"COND COOLING / ROOF / FLOOR DRAINS"},{"outfall":"001","parameter":"Nitrogen, ammonia, total [as NH3]","parameter_code":"34726","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"COND COOLING / ROOF / FLOOR DRAINS"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":"576","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Net rate of additionof heat","parameter_code":"61575","statistic":"daily maximum","qualifier":"<=","value":"3200","unit":"MBTU/hr","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Net rate of additionof heat","parameter_code":"61575","statistic":"daily maximum","qualifier":"<=","value":"5620","unit":"MBTU/hr","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"daily maximum","qualifier":"<=","value":"16","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"daily maximum","qualifier":"<=","value":"16","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"daily maximum","qualifier":"<=","value":"28","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"001","parameter":"Temp. difference, winter [deg. F]","parameter_code":"70014","statistic":"daily maximum","qualifier":"<=","value":"28","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"COND COOL / ROOF / FLOOR DRAIN"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".005","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".004","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".06","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"daily maximum","qualifier":"<=","value":".0046","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"002","parameter":"Ammonia [as N] + unionized ammonia","parameter_code":"61574","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAINS & EMERG. OVERFLOW"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".03","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Nitrogen, ammonia, total [as NH3]","parameter_code":"34726","statistic":"daily maximum","qualifier":"<=","value":".8","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SETTLING SYSTEM DISCHARGE"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"monthly average","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily maximum","qualifier":"<=","value":".03","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Barium, total [as Ba]","parameter_code":"01007","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED WASTE AT 005"},{"outfall":"005","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".04","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".04","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".16","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":".86","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Aluminum, dissolved [as Al]","parameter_code":"01106","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED WASTE AT 005"},{"outfall":"005","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"daily maximum","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COMBINED WASTE AT 005"},{"outfall":"005","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"daily maximum","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"daily maximum","qualifier":"<=","value":".15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Nitrogen, ammonia, total [as NH3]","parameter_code":"34726","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"005","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":"<=","value":"9.99","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WASTE TREATMENT FACILITY"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".005","unit":"mL/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".01","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".004","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".06","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"STORM DRAIN DISCHARGE"},{"outfall":"006","parameter":"Ammonia [as N] + unionized ammonia","parameter_code":"61574","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"STORM DRAIN DISCHARGE"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","url":"https://passage-data.com/api/v1/permits?state=NY&sic=4911","page":"https://passage-data.com/dmr/s/NY/4911"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0002321"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0002321"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0002321"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0002321"}]}