{"permit":"NY0001490","name":"OMEGA WIRE, INC","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0001490"},"about":[{"label":"What it is","text":"Plating And Polishing (EPA's industry listing)"},{"label":"Where","text":"Camden, New York","href":"https://www.openstreetmap.org/?mlat=43.335778&mlon=-75.75025#map=14/43.335778/-75.75025"},{"label":"Last 12 months","text":"Over a limit 5 times, last in August 2026 (Tin, total [as Sn]; Fluoroborates; Copper, total [as Cu]). 3 of 39 reports filed late"},{"label":"Permit","text":"In force until Nov 30, 2029"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"NY","sic":"34","permits":11,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=34","page":"https://passage-data.com/dmr/s/NY/34"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":5,"over_by":[["Tin, total [as Sn]",2],["Fluoroborates",2],["Copper, total [as Cu]",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Tin, total [as Sn]","times":2,"find_limits":{"parameter":"tin","place":"US-NY","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=tin&place=US-NY&medium=water_discharge"},{"parameter":"Copper, total [as Cu]","times":1,"find_limits":{"parameter":"copper","place":"US-NY","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=copper&place=US-NY&medium=surface_water"}],"limits":[{"outfall":"003","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY OIL AND GREASE"},{"outfall":"003","parameter":"Temp. diff. between up/down stream deg. F","parameter_code":"03772","statistic":"daily maximum","qualifier":"<=","value":"5","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"Temp. diff. between up/down stream deg. F","parameter_code":"03772","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"deg F","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"003","parameter":"Oil and grease visual","parameter_code":"84066","statistic":"EPA's \"NONSP MX\"","qualifier":null,"value":null,"unit":"N=0;Y=1","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY OIL AND GREASE"},{"outfall":"004","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily minimum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Fluoride, dissolved [as F]","parameter_code":"00950","statistic":"daily maximum","qualifier":"<=","value":"3.1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Fluoroborates","parameter_code":"00952","statistic":"daily maximum","qualifier":"<=","value":"31","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":"2.1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"3.4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":".43","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".69","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Tin, total [as Sn]","parameter_code":"01102","statistic":"daily maximum","qualifier":"<=","value":".38","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"004","parameter":"Oil and grease visual","parameter_code":"84066","statistic":"EPA's \"NONSP MX\"","qualifier":null,"value":null,"unit":"N=0;Y=1","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER FROM ELECTROPLATING"},{"outfall":"005","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"005","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NON-CONTACT COOLING WATER"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY OIL AND GREASE"},{"outfall":"005","parameter":"Oil and grease visual","parameter_code":"84066","statistic":"EPA's \"NONSP MX\"","qualifier":null,"value":null,"unit":"N=0;Y=1","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY OIL AND GREASE"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"34"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=34","url":"https://passage-data.com/api/v1/permits?state=NY&sic=34","page":"https://passage-data.com/dmr/s/NY/34"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"tin","place":"US-NY","medium":"water_discharge"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=tin&place=US-NY&medium=water_discharge","url":"https://passage-data.com/api/v1/limits?parameter=tin&place=US-NY&medium=water_discharge","page":"https://passage-data.com/limits/US-NY/tin"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0001490"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0001490"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0001490"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0001490"}]}