{"permit":"NY0000515","name":"FELIX SCHOELLER TECH PAPERS","state":"NY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NY0000515"},"about":[{"label":"What it is","text":"Paper Coated And Laminated (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Pulaski, New York","href":"https://www.openstreetmap.org/?mlat=43.555583&mlon=-76.100833#map=14/43.555583/-76.100833"},{"label":"Last 12 months","text":"Over a limit 3 times, last in August 2026 (Temperature, water deg. fahrenheit). 1 required value not reported"},{"label":"Permit","text":"Expired Apr 30, 2016; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2015-11-02","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/NY0000515#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"NY","sic":"26","permits":22,"list":"https://passage-data.com/api/v1/permits?state=NY&sic=26","page":"https://passage-data.com/dmr/s/NY/26"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":3,"over_by":[["Temperature, water deg. fahrenheit",3]],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":"<=","value":"72","unit":"deg F","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":"<=","value":"72","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"75","unit":"deg F","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"75","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Turbidity","parameter_code":"00070","statistic":"monthly average","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Turbidity","parameter_code":"00070","statistic":"daily maximum","qualifier":"<=","value":"75","unit":"NTU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"82","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"110","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"220","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"370","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".3","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTEWATER TREATMENT PLANT EFF"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTEWATER TREATMENT PLANT EFF"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".025","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTEWATER TREATMENT PLANT EFF"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":".15","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTEWATER TREATMENT PLANT EFF"},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":"<=","value":"26","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":false,"months":"all","limit_set":"WASTEWATER TREATMENT PLANT EFF"},{"outfall":"001","parameter":"Temp. diff. between up/down stream deg. F","parameter_code":"03772","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"deg F","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Chloroform","parameter_code":"32106","statistic":"daily maximum","qualifier":"<=","value":".225","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTEWATER TREATMENT PLANT EFF"},{"outfall":"001","parameter":"Phenols","parameter_code":"46000","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTEWATER TREATMENT PLANT EFF"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS (3), COOLING(4), AND SANITARY"},{"outfall":"001","parameter":"Formaldehyde","parameter_code":"71880","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":false,"months":"all","limit_set":"WASTEWATER TREATMENT PLANT EFF"},{"outfall":"001","parameter":"Phenols, chlorinated","parameter_code":"74015","statistic":"monthly average","qualifier":"<=","value":".08","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Phenols, chlorinated","parameter_code":"74015","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Phenols, chlorinated","parameter_code":"74015","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Phenols, chlorinated","parameter_code":"74015","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Phenolic compounds, unchlorinated","parameter_code":"78218","statistic":"monthly average","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Phenolic compounds, unchlorinated","parameter_code":"78218","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Phenolic compounds, unchlorinated","parameter_code":"78218","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"001","parameter":"Phenolic compounds, unchlorinated","parameter_code":"78218","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY PARAMETERS PHENOLS AND COPPER"},{"outfall":"03C","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"75","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"Solids, settleable","parameter_code":"00545","statistic":"monthly average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"Flow, wastewater by-passing trtmnt plant","parameter_code":"50049","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"03C","parameter":"Flow, wastewater by-passing trtmnt plant","parameter_code":"50049","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"WWTP EMERGENCY BYPASS"},{"outfall":"SLG","parameter":"Sludge build-up in water","parameter_code":"01316","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ft","report_only":true,"enforceable":true,"months":"all","limit_set":"SETTLING LAGOON"},{"outfall":"SLG","parameter":"Sludge build-up in water","parameter_code":"01316","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ft","report_only":true,"enforceable":true,"months":"all","limit_set":"EQUALIZATION LAGOON"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NY","sic":"26"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NY&sic=26","url":"https://passage-data.com/api/v1/permits?state=NY&sic=26","page":"https://passage-data.com/dmr/s/NY/26"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NY0000515"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NY0000515"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NY0000515"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NY0000515"}]}