{"permit":"NJ0004375","name":"HOEGANAES CORP","state":"NJ","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/NJ0004375"},"about":[{"label":"What it is","text":"Primary Metal Products (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Cinnaminson Twp, New Jersey","href":"https://www.openstreetmap.org/?mlat=40.024433&mlon=-74.984203#map=14/40.024433/-74.984203"},{"label":"Last 12 months","text":"Over a limit 6 times, last in August 2026 (Oxygen demand, chem. [high level] [COD]; Zinc, total recoverable; Copper, total recoverable). 2 of 22 reports filed late"},{"label":"Permit","text":"Expired Oct 31, 2026"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2026-05-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/NJ0004375#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"NJ","sic":"33","permits":6,"list":"https://passage-data.com/api/v1/permits?state=NJ&sic=33","page":"https://passage-data.com/dmr/s/NJ/33"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":6,"over_by":[["Oxygen demand, chem. [high level] [COD]",3],["Zinc, total recoverable",1],["Copper, total recoverable",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Oxygen demand, chem. [high level] [COD]","times":3,"find_limits":{"parameter":"cod","place":"US-NJ","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=cod&place=US-NJ&medium=water_discharge"},{"parameter":"Zinc, total recoverable","times":1,"find_limits":{"parameter":"zinc","place":"US-NJ","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=zinc&place=US-NJ&medium=surface_water"},{"parameter":"Copper, total recoverable","times":1,"find_limits":{"parameter":"copper","place":"US-NJ","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=copper&place=US-NJ&medium=surface_water"}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg C","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Temperature, water deg. centigrade","parameter_code":"00010","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"deg C","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"6.69","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"23","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"daily maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":"<=","value":"2.4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":"<=","value":".32","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":"<=","value":".41","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"monthly average","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"monthly average","qualifier":"<=","value":".05","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chromium, hexavalent dissolved [as Cr]","parameter_code":"01220","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chromium, hexavalent dissolved [as Cr]","parameter_code":"01220","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chromium, hexavalent dissolved [as Cr]","parameter_code":"01220","statistic":"monthly average","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chromium, hexavalent dissolved [as Cr]","parameter_code":"01220","statistic":"daily maximum","qualifier":"<=","value":".05","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chlorine produced oxidants","parameter_code":"03773","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Chlorine produced oxidants","parameter_code":"03773","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"LC50 Static 48Hr Acute Ceriodaphnia dubia","parameter_code":"TAA3B","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"23","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":".7","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"1.45","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":".53","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":".84","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"monthly average","qualifier":"<=","value":".32","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"daily maximum","qualifier":"<=","value":".77","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"monthly average","qualifier":"<=","value":".005","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"daily maximum","qualifier":"<=","value":".007","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"monthly average","qualifier":"<=","value":".003","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":"<=","value":".01","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"monthly average","qualifier":"<=","value":".023","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":"<=","value":".043","unit":"kg/d","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"NJ","sic":"33"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=NJ&sic=33","url":"https://passage-data.com/api/v1/permits?state=NJ&sic=33","page":"https://passage-data.com/dmr/s/NJ/33"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"cod","place":"US-NJ","medium":"water_discharge"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=cod&place=US-NJ&medium=water_discharge","url":"https://passage-data.com/api/v1/limits?parameter=cod&place=US-NJ&medium=water_discharge","page":"https://passage-data.com/limits/US-NJ/cod"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"NJ0004375"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=NJ0004375"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"NJ0004375"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=NJ0004375"}]}