{"permit":"MS0002232","name":"TRONOX LLC, HAMILTON FACILITY","state":"MS","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/MS0002232"},"about":[{"label":"What it is","text":"Inorganic Pigments (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Hamilton, Mississippi","href":"https://www.openstreetmap.org/?mlat=33.726833&mlon=-88.469722#map=14/33.726833/-88.469722"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Nov 30, 2029"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"MS","sic":"28","permits":23,"list":"https://passage-data.com/api/v1/permits?state=MS&sic=28","page":"https://passage-data.com/dmr/s/MS/28"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"101","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":["MAY","JUN","JUL","AUG","SEP","OCT"],"limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":"2.96","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"5.92","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":"<=","value":"1.5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":null,"value":null,"unit":"occur/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"101","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly maximum","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER/STORMWATER RUNOFF"},{"outfall":"201","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"1346","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"2019","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".042","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".323","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":"2.25","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"17.3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"annual average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"annual average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Titanium, total [as Ti]","parameter_code":"01152","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"monthly average","qualifier":"<=","value":".011","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":".019","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"monthly average","qualifier":"<=","value":".59","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":"1.02","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly maximum","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WASTEWATER"},{"outfall":"201","parameter":"%Effect Static Renewal 7 Day Chronic Ceriodaphnia dubia","parameter_code":"TCP3B","statistic":"minimum","qualifier":">=","value":"6.37","unit":"%","report_only":false,"enforceable":true,"months":"all","limit_set":"External Outfall"},{"outfall":"201","parameter":"%Effect Static Renewal 7Day Chronic Pimephales promelas","parameter_code":"TCP6C","statistic":"minimum","qualifier":">=","value":"6.37","unit":"%","report_only":false,"enforceable":true,"months":"all","limit_set":"External Outfall"},{"outfall":"301","parameter":"E. coli","parameter_code":"51040","statistic":"annual average","qualifier":"<=","value":"126","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"INTERNAL OUTFALL"},{"outfall":"301","parameter":"E. coli","parameter_code":"51040","statistic":"quarterly maximum","qualifier":"<=","value":"410","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"INTERNAL OUTFALL"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"MS","sic":"28"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=MS&sic=28","url":"https://passage-data.com/api/v1/permits?state=MS&sic=28","page":"https://passage-data.com/dmr/s/MS/28"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"MS0002232"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=MS0002232"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"MS0002232"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=MS0002232"}]}