{"permit":"MD0058611","name":"TRANS-TECH,INC.","state":"MD","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/MD0058611"},"about":[{"label":"What it is","text":"Electronic Components (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Adamstown, Maryland","href":"https://www.openstreetmap.org/?mlat=39.312221&mlon=-77.474444#map=14/39.312221/-77.474444"},{"label":"Last 12 months","text":"No values over a limit. 2 of 22 reports filed late"},{"label":"Permit","text":"In force until Jan 31, 2027"}],"renewal_due":{"date":"2026-08-04","when":"Aug 4, 2026, overdue","urgent":true},"renewal_check":{"offered_because":"application_overdue","application_due":"2026-08-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/MD0058611#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"MD","sic":"36","permits":2,"list":"https://passage-data.com/api/v1/permits?state=MD&sic=36"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Oxygen, dissolved [DO]","parameter_code":"00300","statistic":"instantaneous minimum","qualifier":">=","value":"5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"maximum monthly average","qualifier":"<=","value":"25","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"001","parameter":"E. coli","parameter_code":"51040","statistic":"maximum monthly geometric mean","qualifier":"<=","value":"126","unit":"MPN/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"Oxygen, dissolved [DO]","parameter_code":"00300","statistic":"minimum","qualifier":">=","value":"5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"18","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"48","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"monthly average","qualifier":"<=","value":"13.6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"Fluoride, total [as F]","parameter_code":"00951","statistic":"daily maximum","qualifier":"<=","value":"25.1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"21-DP-1841"},{"outfall":"002","parameter":"Organics, total toxic [TTO]","parameter_code":"78141","statistic":"daily maximum","qualifier":"<=","value":"1.07","unit":"mg/L","report_only":false,"enforceable":true,"months":["JUN","DEC"],"limit_set":"21-DP-1841"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"MD","sic":"36"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=MD&sic=36","url":"https://passage-data.com/api/v1/permits?state=MD&sic=36"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"MD0058611"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=MD0058611"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"MD0058611"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=MD0058611"}]}