{"permit":"MA0003832","name":"GILLETTE COMPANY","state":"MA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/MA0003832"},"about":[{"label":"What it is","text":"Cutlery (EPA's industry listing)"},{"label":"Where","text":"South Boston, Massachusetts","href":"https://www.openstreetmap.org/?mlat=42.35&mlon=-71.058333#map=14/42.35/-71.058333"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"Expired Sep 30, 2017; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2017-04-03","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/MA0003832#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":null,"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"83","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"26","unit":"MGD","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"23.5","unit":"MGD","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Salinity","parameter_code":"00480","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Solids, total","parameter_code":"00500","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS, NCCW & BOILER BLOWDOWN QUARTERLY MONITORING"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS, NCCW & BOILER BLOWDOWN QUARTERLY MONITORING"},{"outfall":"001","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Oxidants, total residual","parameter_code":"34044","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Temperature Increase Deg. F","parameter_code":"51543","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Temperature Increase Deg. F","parameter_code":"51543","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Ammonia [as N] + unionized ammonia","parameter_code":"61574","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"001","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"NCCW, PROCESS, BOILER BLOWDOWN"},{"outfall":"001","parameter":"LC50 Static Renewal 48Hr Acute Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TAM3E","statistic":"daily minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":["AUG"],"limit_set":"TOXICITY TEST"},{"outfall":"002","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"83","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"26","unit":"MGD","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"23.5","unit":"MGD","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY MONITORING OF OUTFALL 002"},{"outfall":"002","parameter":"Oil and grease [soxhlet extr.] tot.","parameter_code":"00550","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY MONITORING OF OUTFALL 002"},{"outfall":"002","parameter":"Temperature Increase Deg. F","parameter_code":"51543","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Temperature Increase Deg. F","parameter_code":"51543","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"002","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"PROCESS WATER, FILTER BACKWASH, AND NON-CONTACT COOLING H20"},{"outfall":"003","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"83","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"8.1","unit":"MGD","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"7.4","unit":"MGD","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Quarterly Monitoring for 003"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Quarterly Monitoring for 003"},{"outfall":"003","parameter":"Temperature Increase Deg. F","parameter_code":"51543","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Temperature Increase Deg. F","parameter_code":"51543","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"003","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"Process Water, Strainer Flush, and Non-contact cooling H2)"},{"outfall":"004","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"83","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"19.6","unit":"MGD","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"15.4","unit":"MGD","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Temperature Increase Deg. F","parameter_code":"51543","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Temperature Increase Deg. F","parameter_code":"51543","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"Non-contact Cooling Water"},{"outfall":"004","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"Non-contact Cooling Water"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":"<=","value":"40","unit":"MGD","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"SEAWATER AT COOLING WATER INTAKE STRUCTURE"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":"<=","value":"30","unit":"MGD","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"SEAWATER AT COOLING WATER INTAKE STRUCTURE"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"MGD","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"SEAWATER AT COOLING WATER INTAKE STRUCTURE"},{"outfall":"005","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":"<=","value":"35","unit":"MGD","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"SEAWATER AT COOLING WATER INTAKE STRUCTURE"},{"outfall":"SUM","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"SUM OF HEATED EFFLUENT FROM OUTFALLS 001, 002, 003, & 004 TO FORT POINT CHANNEL"},{"outfall":"SUM","parameter":"Heat [summer] [per day]","parameter_code":"81398","statistic":"daily maximum","qualifier":"<=","value":"8782","unit":"MBTU/d","report_only":false,"enforceable":true,"months":["JUN","JUL","AUG","SEP"],"limit_set":"SUM OF HEATED EFFLUENT FROM OUTFALLS 001, 002, 003, & 004 TO FORT POINT CHANNEL"},{"outfall":"SUM","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"monthly average","qualifier":null,"value":null,"unit":"MBTU/d","report_only":true,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"SUM OF HEATED EFFLUENT FROM OUTFALLS 001, 002, 003, & 004 TO FORT POINT CHANNEL"},{"outfall":"SUM","parameter":"Heat [winter] [per day]","parameter_code":"81399","statistic":"daily maximum","qualifier":"<=","value":"8782","unit":"MBTU/d","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","APR","MAY","OCT","NOV","DEC"],"limit_set":"SUM OF HEATED EFFLUENT FROM OUTFALLS 001, 002, 003, & 004 TO FORT POINT CHANNEL"}],"next":[{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"MA0003832"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=MA0003832"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"MA0003832"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=MA0003832"}]}