{"permit":"MA0003557","name":"HOLTEC PILGRIM, LLC","state":"MA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/MA0003557"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Plymouth, Massachusetts","href":"https://www.openstreetmap.org/?mlat=41.944167&mlon=-70.579444#map=14/41.944167/-70.579444"},{"label":"Last 12 months","text":"Over a limit 3 times, last in July 2026 (Solids, total suspended)"},{"label":"Permit","text":"Expired Jun 30, 2025; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2025-01-01","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/MA0003557#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"MA","sic":"4911","permits":6,"list":"https://passage-data.com/api/v1/permits?state=MA&sic=4911","page":"https://passage-data.com/dmr/s/MA/4911"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":3,"over_by":[["Solids, total suspended",3]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Solids, total suspended","times":3,"find_limits":{"parameter":"total suspended solids","place":"US-MA","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-MA&medium=water_discharge"}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Salinity","parameter_code":"00480","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/kg","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Solids, total","parameter_code":"00500","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Sodium nitrite","parameter_code":"00728","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Sodium nitrite","parameter_code":"00728","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Oxidants, total residual","parameter_code":"34044","statistic":"monthly average","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Oxidants, total residual","parameter_code":"34044","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":"224","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Duration of discharge","parameter_code":"81381","statistic":"daily maximum","qualifier":null,"value":null,"unit":"hr","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Tolytriazole","parameter_code":"85813","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"Tolytriazole","parameter_code":"85813","statistic":"daily maximum","qualifier":"<=","value":"1.48","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WATER"},{"outfall":"001","parameter":"LC50 Static 48Hr Acute Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TAA3E","statistic":"daily maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"001","parameter":"LC50 Static 48Hr Acute Menidia","parameter_code":"TAA6B","statistic":"daily maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"WHOLE EFFLUENT TOXICITY TESTING"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"THERMAL BACKWASH"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":"28","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"THERMAL BACKWASH"},{"outfall":"002","parameter":"Number of Events","parameter_code":"51484","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"#","report_only":false,"enforceable":true,"months":"all","limit_set":"THERMAL BACKWASH"},{"outfall":"002","parameter":"Duration of discharge","parameter_code":"81381","statistic":"daily maximum","qualifier":null,"value":null,"unit":"hr","report_only":true,"enforceable":true,"months":"all","limit_set":"THERMAL BACKWASH"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"004","parameter":"Cyanide, free [as free]","parameter_code":"00717","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Cyanide, free [as free]","parameter_code":"00717","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Antimony, total recoverable","parameter_code":"01268","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Antimony, total recoverable","parameter_code":"01268","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Total phenols","parameter_code":"03604","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Total phenols","parameter_code":"03604","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"004","parameter":"Chromium, hexavalent tot recoverable","parameter_code":"78247","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Chromium, hexavalent tot recoverable","parameter_code":"78247","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"004","parameter":"Phthalates, total","parameter_code":"78721","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-2)"},{"outfall":"004","parameter":"Phthalates, total","parameter_code":"78721","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-4)"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"005","parameter":"Cyanide, free [as free]","parameter_code":"00717","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Cyanide, free [as free]","parameter_code":"00717","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Antimony, total recoverable","parameter_code":"01268","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Antimony, total recoverable","parameter_code":"01268","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Total phenols","parameter_code":"03604","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Total phenols","parameter_code":"03604","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"YARD DRAINS"},{"outfall":"005","parameter":"Chromium, hexavalent tot recoverable","parameter_code":"78247","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Chromium, hexavalent tot recoverable","parameter_code":"78247","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"005","parameter":"Phthalates, total","parameter_code":"78721","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-27A)"},{"outfall":"005","parameter":"Phthalates, total","parameter_code":"78721","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE CP-4)"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"006","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"007","parameter":"Cyanide, free [as free]","parameter_code":"00717","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Cadmium, total recoverable","parameter_code":"01113","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Antimony, total recoverable","parameter_code":"01268","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Total phenols","parameter_code":"03604","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Polychlorinated biphenyls [PCBs]","parameter_code":"39516","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"STORMWATER"},{"outfall":"007","parameter":"Chromium, hexavalent tot recoverable","parameter_code":"78247","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"007","parameter":"Phthalates, total","parameter_code":"78721","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ELECTRIC VAULT (MANHOLE MH-L)"},{"outfall":"010","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":"<=","value":"80","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Oxidants, total residual","parameter_code":"34044","statistic":"monthly average","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Oxidants, total residual","parameter_code":"34044","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":"<=","value":"15.6","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":"19.4","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Velocity of intake","parameter_code":"85663","statistic":"monthly average","qualifier":null,"value":null,"unit":"ft/sec","report_only":true,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"010","parameter":"Velocity of intake","parameter_code":"85663","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"ft/sec","report_only":false,"enforceable":true,"months":"all","limit_set":"SALT SERVICE WATER"},{"outfall":"011","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.1","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.4","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Boron, total [as B]","parameter_code":"01022","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Boron, total [as B]","parameter_code":"01022","statistic":"daily maximum","qualifier":"<=","value":"5.6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Boron, total [as B]","parameter_code":"01022","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Boron, total [as B]","parameter_code":"01022","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":"<=","value":".015","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"011","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":".06","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"MAKE UP WATER AND DEMINERALIZE"},{"outfall":"012","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"INTAKE SCREEWASH WATER"},{"outfall":"012","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"INTAKE SCREEWASH WATER"},{"outfall":"012","parameter":"Oxidants, total residual","parameter_code":"34044","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"INTAKE SCREEWASH WATER"},{"outfall":"012","parameter":"Oxidants, total residual","parameter_code":"34044","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"INTAKE SCREEWASH WATER"},{"outfall":"012","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":"<=","value":"4.1","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"INTAKE SCREEWASH WATER"},{"outfall":"012","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":"4.1","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"INTAKE SCREEWASH WATER"},{"outfall":"014","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6.1","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.4","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Boron, total [as B]","parameter_code":"01022","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Boron, total [as B]","parameter_code":"01022","statistic":"daily maximum","qualifier":"<=","value":"5.6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Boron, total [as B]","parameter_code":"01022","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Boron, total [as B]","parameter_code":"01022","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":"<=","value":".015","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"},{"outfall":"014","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":"<=","value":".06","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"COOLING WATER"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"MA","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=MA&sic=4911","url":"https://passage-data.com/api/v1/permits?state=MA&sic=4911","page":"https://passage-data.com/dmr/s/MA/4911"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"total suspended solids","place":"US-MA","medium":"water_discharge"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-MA&medium=water_discharge","url":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-MA&medium=water_discharge","page":"https://passage-data.com/limits/US-MA/total-suspended-solids"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"MA0003557"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=MA0003557"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"MA0003557"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=MA0003557"}]}