{"permit":"LA0091961","name":"GULF ISLAND FABRICATION, INC.","state":"LA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/LA0091961"},"about":[{"label":"What it is","text":"Ship Building And Repairing (EPA's industry listing)"},{"label":"Where","text":"Houma, Louisiana","href":"https://www.openstreetmap.org/?mlat=29.543056&mlon=-90.697778#map=14/29.543056/-90.697778"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Aug 31, 2028"}],"renewal_due":null,"renewal_check":{"offered_because":"application_due_within_18_months","application_due":"2028-03-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/LA0091961#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"LA","sic":"37","permits":15,"list":"https://passage-data.com/api/v1/permits?state=LA&sic=37","page":"https://passage-data.com/dmr/s/LA/37"},"limits_from_version":null,"record":{"last_filed":"2026-06-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"002","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"125","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh. & eq.washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh. & eq.washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh. & eq.washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"002","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh. & eq.washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh. & eq.washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh. & eq.washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"004","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"004","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Inspector's Trailers"},{"outfall":"005","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"005","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from Dolphin Steel Sales"},{"outfall":"006","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"125","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh.& eq. washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh.& eq. washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh.& eq. washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"006","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh.& eq. washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh.& eq. washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility, veh.& eq. washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"007","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"125","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility washwater; previously monitored hydrostatic test wastewater"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility washwater; previously monitored hydrostatic test wastewater"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility washwater; previously monitored hydrostatic test wastewater"},{"outfall":"007","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility washwater; previously monitored hydrostatic test wastewater"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility washwater; previously monitored hydrostatic test wastewater"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility washwater; previously monitored hydrostatic test wastewater"},{"outfall":"01A","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"125","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01A","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01A","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01A","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01A","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01A","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01B","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"125","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01B","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"01B","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SW runoff; utility & vehicle washwater; previously monitored hydrostatic test & sanitary wastewater"},{"outfall":"101","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Old Vessel Shop"},{"outfall":"101","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Old Vessel Shop"},{"outfall":"101","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Old Vessel Shop"},{"outfall":"101","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Old Vessel Shop"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Old Vessel Shop"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Old Vessel Shop"},{"outfall":"101","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Old Vessel Shop"},{"outfall":"101","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Old Vessel Shop"},{"outfall":"102","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"cont. discharge of treated sanitary wastewater from the East Yard Safety Building"},{"outfall":"102","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"cont. discharge of treated sanitary wastewater from the East Yard Safety Building"},{"outfall":"102","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"cont. discharge of treated sanitary wastewater from the East Yard Safety Building"},{"outfall":"102","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"cont. discharge of treated sanitary wastewater from the East Yard Safety Building"},{"outfall":"102","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"cont. discharge of treated sanitary wastewater from the East Yard Safety Building"},{"outfall":"102","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"cont. discharge of treated sanitary wastewater from the East Yard Safety Building"},{"outfall":"102","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"cont. discharge of treated sanitary wastewater from the East Yard Safety Building"},{"outfall":"102","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"cont. discharge of treated sanitary wastewater from the East Yard Safety Building"},{"outfall":"106","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the North Yard Main Office"},{"outfall":"106","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the North Yard Main Office"},{"outfall":"106","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the North Yard Main Office"},{"outfall":"106","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the North Yard Main Office"},{"outfall":"106","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the North Yard Main Office"},{"outfall":"106","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the North Yard Main Office"},{"outfall":"106","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the North Yard Main Office"},{"outfall":"106","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the North Yard Main Office"},{"outfall":"201","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Pipe Mill"},{"outfall":"201","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Pipe Mill"},{"outfall":"201","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Pipe Mill"},{"outfall":"201","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Pipe Mill"},{"outfall":"201","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Pipe Mill"},{"outfall":"201","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Pipe Mill"},{"outfall":"201","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Pipe Mill"},{"outfall":"201","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Pipe Mill"},{"outfall":"202","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Quality Control Area"},{"outfall":"202","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Quality Control Area"},{"outfall":"202","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Quality Control Area"},{"outfall":"202","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Quality Control Area"},{"outfall":"202","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Quality Control Area"},{"outfall":"202","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Quality Control Area"},{"outfall":"202","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Quality Control Area"},{"outfall":"202","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Quality Control Area"},{"outfall":"301","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Shot Blast"},{"outfall":"301","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Shot Blast"},{"outfall":"301","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Shot Blast"},{"outfall":"301","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Shot Blast"},{"outfall":"301","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Shot Blast"},{"outfall":"301","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Shot Blast"},{"outfall":"301","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Shot Blast"},{"outfall":"301","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard Shot Blast"},{"outfall":"302","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard North Restroom"},{"outfall":"302","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard North Restroom"},{"outfall":"302","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard North Restroom"},{"outfall":"302","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard North Restroom"},{"outfall":"302","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard North Restroom"},{"outfall":"302","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard North Restroom"},{"outfall":"302","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard North Restroom"},{"outfall":"302","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard North Restroom"},{"outfall":"401","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the South Restroom at the East Yard"},{"outfall":"401","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the South Restroom at the East Yard"},{"outfall":"401","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the South Restroom at the East Yard"},{"outfall":"401","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the South Restroom at the East Yard"},{"outfall":"401","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the South Restroom at the East Yard"},{"outfall":"401","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the South Restroom at the East Yard"},{"outfall":"401","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the South Restroom at the East Yard"},{"outfall":"401","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the South Restroom at the East Yard"},{"outfall":"501","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Main Plant"},{"outfall":"501","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Main Plant"},{"outfall":"501","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Main Plant"},{"outfall":"501","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Main Plant"},{"outfall":"501","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Main Plant"},{"outfall":"501","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Main Plant"},{"outfall":"501","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Main Plant"},{"outfall":"501","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of treated sanitary wastewater from the East Yard Main Plant"},{"outfall":"602A","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of hydrostatic test water from East Yard- new pipes"},{"outfall":"602A","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of hydrostatic test water from East Yard- new pipes"},{"outfall":"602A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of hydrostatic test water from East Yard- new pipes"},{"outfall":"602A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of hydrostatic test water from East Yard- new pipes"},{"outfall":"602A","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of hydrostatic test water from East Yard- new pipes"},{"outfall":"602A","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of hydrostatic test water from East Yard- new pipes"},{"outfall":"602A","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of hydrostatic test water from East Yard- new pipes"},{"outfall":"602B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"BTEX","parameter_code":"49491","statistic":"daily maximum","qualifier":"<=","value":"250","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"602B","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"701","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard New Fabrication Shop"},{"outfall":"701","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard New Fabrication Shop"},{"outfall":"701","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard New Fabrication Shop"},{"outfall":"701","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard New Fabrication Shop"},{"outfall":"701","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard New Fabrication Shop"},{"outfall":"701","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard New Fabrication Shop"},{"outfall":"701","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard New Fabrication Shop"},{"outfall":"701","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"discharge of treated sanitary wastewater from the East Yard New Fabrication Shop"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"LA","sic":"37"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=LA&sic=37","url":"https://passage-data.com/api/v1/permits?state=LA&sic=37","page":"https://passage-data.com/dmr/s/LA/37"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"LA0091961"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=LA0091961"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"LA0091961"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=LA0091961"}]}