{"permit":"LA0042731","name":"Entergy Operations, Inc.- River Bend Station","state":"LA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/LA0042731"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"St. Francisville, Louisiana","href":"https://www.openstreetmap.org/?mlat=30.758056&mlon=-91.3325#map=14/30.758056/-91.3325"},{"label":"Last 12 months","text":"No values over a limit. 1 of 163 reports filed late"},{"label":"Permit","text":"In force until Apr 30, 2029"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"LA","sic":"4911","permits":29,"list":"https://passage-data.com/api/v1/permits?state=LA&sic=4911","page":"https://passage-data.com/dmr/s/LA/4911"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":"<=","value":"105","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"110","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"001 yearly"},{"outfall":"001","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"001 yearly"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"monthly average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Cooling Tower Blowdown"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TEM3D","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TEM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TEM6C","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TEM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex","parameter_code":"TOM3D","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex","parameter_code":"TOM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas","parameter_code":"TOM6C","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas","parameter_code":"TOM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"001","parameter":"Coef Of Var Static Renewal 48Hr Acute D. pulex","parameter_code":"TQM3D","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Daphnia Pulex)"},{"outfall":"001","parameter":"Coef Of Var Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TQM6C","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Biomonitoring for Outfall 001 (Pimephales Promelas)"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent sw runoff"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent sw runoff"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent sw runoff"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent sw runoff"},{"outfall":"002","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent sw runoff"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent sw runoff"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume WW"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"004","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"005","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of stormwater runoff"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of clarifier underflow"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of clarifier underflow"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"BTEX","parameter_code":"49491","statistic":"daily maximum","qualifier":"<=","value":"250","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Hydrostatic test wastewater"},{"outfall":"101","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low level radioactive low volume ww"},{"outfall":"101","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low level radioactive low volume ww"},{"outfall":"101","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low level radioactive low volume ww"},{"outfall":"101","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low level radioactive low volume ww"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low level radioactive low volume ww"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low level radioactive low volume ww"},{"outfall":"104","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"300","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of vehicle ww"},{"outfall":"104","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of vehicle ww"},{"outfall":"104","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of vehicle ww"},{"outfall":"104","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of vehicle ww"},{"outfall":"104","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of vehicle ww"},{"outfall":"104","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of vehicle ww"},{"outfall":"104","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of vehicle ww"},{"outfall":"201","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Internall intermittent discharge of treated sanitary ww"},{"outfall":"201","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Internall intermittent discharge of treated sanitary ww"},{"outfall":"201","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Internall during maintenance activities"},{"outfall":"201","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Internall during maintenance activities"},{"outfall":"201","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Internall during maintenance activities"},{"outfall":"201","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Internall during maintenance activities"},{"outfall":"201","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Internall during maintenance activities"},{"outfall":"201","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Internall during maintenance activities"},{"outfall":"201","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"Internall intermittent discharge of treated sanitary ww"},{"outfall":"201","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"Internall intermittent discharge of treated sanitary ww"},{"outfall":"301","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"301","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of metal cleaning ww"},{"outfall":"401","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"401","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"401","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"401","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"401","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"401","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"501","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low voluem ww"},{"outfall":"501","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low voluem ww"},{"outfall":"501","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low voluem ww"},{"outfall":"501","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low voluem ww"},{"outfall":"501","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low voluem ww"},{"outfall":"501","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low voluem ww"},{"outfall":"601","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"601","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"601","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"601","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"601","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"601","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low volume ww"},{"outfall":"EQ32","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"cooling water intake"},{"outfall":"EQ32","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"cooling water intake"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"LA","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=LA&sic=4911","url":"https://passage-data.com/api/v1/permits?state=LA&sic=4911","page":"https://passage-data.com/dmr/s/LA/4911"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"LA0042731"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=LA0042731"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"LA0042731"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=LA0042731"}]}