{"permit":"LA0005941","name":"CITGO Petroleum Corporation - Lake Charles Manufacturing Complex","state":"LA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/LA0005941"},"about":[{"label":"What it is","text":"Petroleum Refining (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Lake Charles, Louisiana","href":"https://www.openstreetmap.org/?mlat=30.183611&mlon=-93.317222#map=14/30.183611/-93.317222"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Jun 30, 2029"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"LA","sic":"29","permits":26,"list":"https://passage-data.com/api/v1/permits?state=LA&sic=29","page":"https://passage-data.com/dmr/s/LA/29"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"1304","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"2455","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":"<=","value":"486","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"1061","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"monthly average","qualifier":"<=","value":"1620","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"2579","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":"<=","value":".2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Phenolics, total recoverable","parameter_code":"32730","statistic":"monthly average","qualifier":"<=","value":"9.1","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Phenolics, total recoverable","parameter_code":"32730","statistic":"daily maximum","qualifier":"<=","value":"21.7","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Enterococci","parameter_code":"61211","statistic":"monthly geometric mean","qualifier":"<=","value":"35","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Enterococci","parameter_code":"61211","statistic":"daily maximum","qualifier":"<=","value":"135","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"001","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly total","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"001","parameter":"Pass/Fail Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TGP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Pass/Fail Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TGP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Pass/Fail Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TGP6J","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Pass/Fail Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TGP6J","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia)","parameter_code":"TLP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia)","parameter_code":"TLP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TLP6J","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TLP6J","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TOP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TOP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TOP6J","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TOP6J","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TPP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TPP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TPP6J","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TPP6J","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Coef Of Var Static Renewal 7Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TQP3E","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Coef Of Var Static Renewal 7Day Chronic Menidia beryllina","parameter_code":"TQP6J","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"stormwater runoff"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"stormwater runoff"},{"outfall":"002","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"stormwater runoff"},{"outfall":"002","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"stormwater runoff"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"stormwater runoff"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"stormwater runoff"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Enterococci","parameter_code":"61211","statistic":"monthly geometric mean","qualifier":"<=","value":"35","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Enterococci","parameter_code":"61211","statistic":"daily maximum","qualifier":"<=","value":"135","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"003","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly total","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"treated process wastewater"},{"outfall":"003","parameter":"Pass/Fail Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TGP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Pass/Fail Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TGP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Pass/Fail Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TGP6J","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Pass/Fail Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TGP6J","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia)","parameter_code":"TLP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia)","parameter_code":"TLP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TLP6J","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TLP6J","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TOP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TOP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TOP6J","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TOP6J","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TPP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TPP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TPP6J","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Menidia beryllina","parameter_code":"TPP6J","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"003","parameter":"Coef Of Var Static Renewal 7Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TQP3E","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Mysidopsis bahia"},{"outfall":"003","parameter":"Coef Of Var Static Renewal 7Day Chronic Menidia beryllina","parameter_code":"TQP6J","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Menidia beryllina"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"noncontact cooling water"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"noncontact cooling water"},{"outfall":"004","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"noncontact cooling water"},{"outfall":"004","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"quarterly reporting -- outfall 004"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"noncontact cooling water"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"noncontact cooling water"},{"outfall":"004","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"noncontact cooling water"},{"outfall":"004","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly total","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"noncontact cooling water"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"006","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"006","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"009","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"009","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"009","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"009","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"009","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"009","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"010","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"010","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"010","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"010","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"010","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"010","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"011","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"011","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"011","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"011","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"011","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"011","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"012","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"012","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"012","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"012","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"012","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"012","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"nonprocess area stormwater"},{"outfall":"014","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"Enterococci","parameter_code":"61211","statistic":"monthly geometric mean","qualifier":"<=","value":"35","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"Enterococci","parameter_code":"61211","statistic":"daily maximum","qualifier":"<=","value":"135","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"014","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"101","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"BTEX","parameter_code":"49491","statistic":"daily maximum","qualifier":"<=","value":"250","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"hydrostatic test wastewater"},{"outfall":"103","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"overflow of stormwater runoff and de minimis utility, process, and non-process wastewaters"},{"outfall":"103","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"overflow of stormwater runoff and de minimis utility, process, and non-process wastewaters"},{"outfall":"103","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"overflow of stormwater runoff and de minimis utility, process, and non-process wastewaters"},{"outfall":"103","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"overflow of stormwater runoff and de minimis utility, process, and non-process wastewaters"},{"outfall":"103","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"monthly average","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"overflow of stormwater runoff and de minimis utility, process, and non-process wastewaters"},{"outfall":"103","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"lb/d","report_only":true,"enforceable":true,"months":"all","limit_set":"overflow of stormwater runoff and de minimis utility, process, and non-process wastewaters"},{"outfall":"103","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"overflow of stormwater runoff and de minimis utility, process, and non-process wastewaters"},{"outfall":"103","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"overflow of stormwater runoff and de minimis utility, process, and non-process wastewaters"},{"outfall":"106","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"Enterococci","parameter_code":"61211","statistic":"monthly geometric mean","qualifier":"<=","value":"35","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"Enterococci","parameter_code":"61211","statistic":"daily maximum","qualifier":"<=","value":"135","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"106","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"treated sanitary wastewater"},{"outfall":"IT01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"cooling water intake"},{"outfall":"IT01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"cooling water intake"},{"outfall":"SUM","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"4163","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"7501","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"3335","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"5227","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":"<=","value":"2126","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"4676","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"monthly average","qualifier":"<=","value":"9160","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"16501","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Sulfide, total [as S]","parameter_code":"00745","statistic":"monthly average","qualifier":"<=","value":"20.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Sulfide, total [as S]","parameter_code":"00745","statistic":"daily maximum","qualifier":"<=","value":"46.1","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":"<=","value":"2.8","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001 & 003 - quarterly reporting"},{"outfall":"SUM","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":"6.2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001 & 003 - quarterly reporting"},{"outfall":"SUM","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":"32.7","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001 & 003 - quarterly reporting"},{"outfall":"SUM","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"94","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001 & 003 - quarterly reporting"},{"outfall":"SUM","parameter":"Oil and grease","parameter_code":"03582","statistic":"monthly average","qualifier":"<=","value":"1215","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"2283","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001, 003, 103 - monthly reporting"},{"outfall":"SUM","parameter":"Phenolics, total recoverable","parameter_code":"32730","statistic":"monthly average","qualifier":"<=","value":"27.1","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001 & 003 - quarterly reporting"},{"outfall":"SUM","parameter":"Phenolics, total recoverable","parameter_code":"32730","statistic":"daily maximum","qualifier":"<=","value":"55.7","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001 & 003 - quarterly reporting"},{"outfall":"SUM","parameter":"Benzo[a]pyrene","parameter_code":"34247","statistic":"monthly average","qualifier":"<=","value":".762","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001 & 003 - quarterly reporting"},{"outfall":"SUM","parameter":"Benzo[a]anthracene","parameter_code":"34526","statistic":"monthly average","qualifier":"<=","value":".762","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"sum of 001 & 003 - quarterly reporting"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"LA","sic":"29"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=LA&sic=29","url":"https://passage-data.com/api/v1/permits?state=LA&sic=29","page":"https://passage-data.com/dmr/s/LA/29"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"LA0005941"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=LA0005941"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"LA0005941"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=LA0005941"}]}