{"permit":"LA0003824","name":"Firestone Polymers, LLC - Lake Charles Facility","state":"LA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/LA0003824"},"about":[{"label":"What it is","text":"Synthetic Rubber (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Lake Charles, Louisiana","href":"https://www.openstreetmap.org/?mlat=30.183889&mlon=-93.332778#map=14/30.183889/-93.332778"},{"label":"Last 12 months","text":"Over a limit once, last in September 2026 (BOD, 5-day, 20 deg. C)"},{"label":"Permit","text":"In force until Jan 31, 2027"}],"renewal_due":{"date":"2026-08-04","when":"Aug 4, 2026, overdue","urgent":true},"renewal_check":{"offered_because":"application_overdue","application_due":"2026-08-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/LA0003824#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"LA","sic":"28","permits":130,"list":"https://passage-data.com/api/v1/permits?state=LA&sic=28","page":"https://passage-data.com/dmr/s/LA/28"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":1,"over_by":[["BOD, 5-day, 20 deg. C",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"BOD, 5-day, 20 deg. C","times":1,"find_limits":{"parameter":"bod","place":"US-LA","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=bod&place=US-LA&medium=water_discharge"}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":"<=","value":"95","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"451","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"676","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"monthly average","qualifier":"<=","value":"2343","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Oxygen demand, chem. [high level] [COD]","parameter_code":"00340","statistic":"daily maximum","qualifier":"<=","value":"3515","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"848","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"1278","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"209","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"313","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY REQUIREMENTS FOR 001"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY REQUIREMENTS FOR 001"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":"<=","value":"92.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":"<=","value":"185","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY REQUIREMENTS FOR 001"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY REQUIREMENTS FOR 001"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly total","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"TREATED PROCESS WASTEWATER"},{"outfall":"001","parameter":"Pass/Fail Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TGP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Pass/Fail Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TGP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Pass/Fail Static Renewal 7Day Chronic Menidia","parameter_code":"TGP6B","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Pass/Fail Static Renewal 7Day Chronic Menidia","parameter_code":"TGP6B","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia)","parameter_code":"TLP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia)","parameter_code":"TLP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Menidia menidia","parameter_code":"TLP6B","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Menidia menidia","parameter_code":"TLP6B","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TOP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TOP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Menidia menidia","parameter_code":"TOP6B","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Menidia menidia","parameter_code":"TOP6B","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TPP3E","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TPP3E","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Menidia menidia","parameter_code":"TPP6B","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Menidia menidia","parameter_code":"TPP6B","statistic":"7-day minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"001","parameter":"Coef Of Var Static Renewal 7Day Chronic Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TQP3E","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Mysidopsis bahia"},{"outfall":"001","parameter":"Coef Of Var Static Renewal 7Day Chronic Menidia menidia","parameter_code":"TQP6B","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing - Menidia beryllina"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 003"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 003"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 003"},{"outfall":"003","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 003"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 003"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 003"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 004"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 004"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 004"},{"outfall":"004","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 004"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 004"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"QUARTERLY REPORTING FOR 004"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":null},{"outfall":"101","parameter":"Enterococci","parameter_code":"61211","statistic":"monthly average","qualifier":"<=","value":"35","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"101","parameter":"Enterococci","parameter_code":"61211","statistic":"daily maximum","qualifier":"<=","value":"135","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"101","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly average","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null},{"outfall":"101","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":null}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"LA","sic":"28"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=LA&sic=28","url":"https://passage-data.com/api/v1/permits?state=LA&sic=28","page":"https://passage-data.com/dmr/s/LA/28"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"bod","place":"US-LA","medium":"water_discharge"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=bod&place=US-LA&medium=water_discharge","url":"https://passage-data.com/api/v1/limits?parameter=bod&place=US-LA&medium=water_discharge","page":"https://passage-data.com/limits/US-LA/bod"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"LA0003824"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=LA0003824"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"LA0003824"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=LA0003824"}]}