{"permit":"LA0002771","name":"Nexpera, LLC: Nexpera-Burnside Facility","state":"LA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/LA0002771"},"about":[{"label":"What it is","text":"Industrial Inorganic Chemicals (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Burnside, Louisiana","href":"https://www.openstreetmap.org/?mlat=30.125833&mlon=-90.908611#map=14/30.125833/-90.908611"},{"label":"Last 12 months","text":"Over a limit 4 times, last in August 2026 (pH range excursions, > 60 minutes; pH range excursions, monthly total accum; Nickel, total [as Ni]). 2 required values not reported. 5 of 92 reports filed late"},{"label":"Permit","text":"Expired Oct 31, 2022; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2022-05-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/LA0002771#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"LA","sic":"28","permits":130,"list":"https://passage-data.com/api/v1/permits?state=LA&sic=28","page":"https://passage-data.com/dmr/s/LA/28"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":4,"over_by":[["pH range excursions, > 60 minutes",2],["pH range excursions, monthly total accum",1],["Nickel, total [as Ni]",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Nickel, total [as Ni]","times":1,"find_limits":{"parameter":"nickel","place":"US-LA","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=nickel&place=US-LA&medium=surface_water"}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"quarterly reporting for outfall 001"},{"outfall":"001","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"quarterly reporting for outfall 001"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly total","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"non-contact cooling, hydrostatic test, process area stormwater; discharge from 101, 201, and 301"},{"outfall":"001","parameter":"Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TEM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TEM3D","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TEM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TEM6C","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex","parameter_code":"TOM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex","parameter_code":"TOM3D","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas","parameter_code":"TOM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas","parameter_code":"TOM6C","statistic":"monthly average minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"001","parameter":"Coef Of Var Static Renewal 48Hr Acute D. pulex","parameter_code":"TQM3D","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Daphnia pulex"},{"outfall":"001","parameter":"Coef Of Var Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TQM6C","statistic":"maximum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Whole Effluent Toxicity Testing for Pimephales promelas"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"non-process area stormwater; uncontaminated utliity wastewater; hydrostatic test water, and 104"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"non-process area stormwater; uncontaminated utliity wastewater; hydrostatic test water, and 104"},{"outfall":"004","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"non-process area stormwater; uncontaminated utliity wastewater; hydrostatic test water, and 104"},{"outfall":"004","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"non-process area stormwater; uncontaminated utliity wastewater; hydrostatic test water, and 104"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"non-process area stormwater; uncontaminated utliity wastewater; hydrostatic test water, and 104"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"non-process area stormwater; uncontaminated utliity wastewater; hydrostatic test water, and 104"},{"outfall":"004","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"non-process area stormwater; uncontaminated utliity wastewater; hydrostatic test water, and 104"},{"outfall":"004","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"non-process area stormwater; uncontaminated utliity wastewater; hydrostatic test water, and 104"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"non-process area stormwater runoff from northern half of facility, etc."},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"non-process area stormwater runoff from northern half of facility, etc."},{"outfall":"005","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"non-process area stormwater runoff from northern half of facility, etc."},{"outfall":"005","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"non-process area stormwater runoff from northern half of facility, etc."},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"non-process area stormwater runoff from northern half of facility, etc."},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"non-process area stormwater runoff from northern half of facility, etc."},{"outfall":"005","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"non-process area stormwater runoff from northern half of facility, etc."},{"outfall":"005","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"non-process area stormwater runoff from northern half of facility, etc."},{"outfall":"101","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"60","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"180","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"1.2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"1.2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".4","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":".72","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"1.2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"2.16","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":".6","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":".6","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":"1.08","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":"1.08","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".82","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":".82","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1.48","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1.48","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":".2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":".2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":".36","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":".36","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".28","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".28","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"bimonthly reporting for outfall 101"},{"outfall":"101","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":".7","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":".7","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"1.5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"1.5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":".7","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":"1.26","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"1.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"2.7","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"101","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly total","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge from the wastewater treatment system"},{"outfall":"104","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"weekly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"monthly geometric mean","qualifier":"<=","value":"200","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"104","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":"<=","value":"400","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"continuous discharge of treated sanitary wastewater"},{"outfall":"201","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"clarifier underflow, boiler feed water softener, blowdown/rinse, condensate"},{"outfall":"201","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"clarifier underflow, boiler feed water softener, blowdown/rinse, condensate"},{"outfall":"204","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"Carbon, tot organic [TOC]","parameter_code":"00680","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"BTEX","parameter_code":"49491","statistic":"daily maximum","qualifier":"<=","value":"250","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"204","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"intermittent discharge of hydrostatic test water"},{"outfall":"301","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact acid cooler water and cooling water basin overflow"},{"outfall":"301","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact acid cooler water and cooling water basin overflow"},{"outfall":"301","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact acid cooler water and cooling water basin overflow"},{"outfall":"301","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"non-contact acid cooler water and cooling water basin overflow"},{"outfall":"301","parameter":"pH range excursions, > 60 minutes","parameter_code":"82581","statistic":"monthly total","qualifier":"<=","value":"0","unit":"occur/mo","report_only":false,"enforceable":true,"months":"all","limit_set":"non-contact acid cooler water and cooling water basin overflow"},{"outfall":"301","parameter":"pH range excursions, monthly total accum","parameter_code":"82582","statistic":"monthly total","qualifier":"<=","value":"446","unit":"min","report_only":false,"enforceable":true,"months":"all","limit_set":"non-contact acid cooler water and cooling water basin overflow"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"LA","sic":"28"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=LA&sic=28","url":"https://passage-data.com/api/v1/permits?state=LA&sic=28","page":"https://passage-data.com/dmr/s/LA/28"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"nickel","place":"US-LA","medium":"surface_water"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=nickel&place=US-LA&medium=surface_water","url":"https://passage-data.com/api/v1/limits?parameter=nickel&place=US-LA&medium=surface_water","page":"https://passage-data.com/limits/US-LA/nickel"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"LA0002771"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=LA0002771"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"LA0002771"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=LA0002771"}]}