{"permit":"KY0092118","name":"Precoat Metals","state":"KY","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/KY0092118"},"about":[{"label":"What it is","text":"Sewerage Systems (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Hawesville, Kentucky","href":"https://www.openstreetmap.org/?mlat=37.93&mlon=-86.776944#map=14/37.93/-86.776944"},{"label":"Last 12 months","text":"Over a limit 4 times, last in March 2026 (E. coli; BOD, 5-day, 20 deg. C). 3 required values not reported. 1 of 24 reports filed late"},{"label":"Permit","text":"In force until Jun 30, 2030"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"KY","sic":"4952","permits":259,"list":"https://passage-data.com/api/v1/permits?state=KY&sic=4952"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":4,"over_by":[["E. coli",2],["BOD, 5-day, 20 deg. C",2]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"BOD, 5-day, 20 deg. C","times":2,"find_limits":{"parameter":"bod","place":"US-KY","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=bod&place=US-KY&medium=water_discharge"}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"89","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"7.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"5.2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"6.81","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"3.29","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"3.3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"monthly average","qualifier":"<=","value":".026","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Cyanide, total [as CN]","parameter_code":"00720","statistic":"daily maximum","qualifier":"<=","value":".068","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Hardness, total [as CaCO3]","parameter_code":"00900","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Hardness, total [as CaCO3]","parameter_code":"00900","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chloride [as Cl]","parameter_code":"00940","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chloride [as Cl]","parameter_code":"00940","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"monthly average","qualifier":"<=","value":".209","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":"<=","value":".435","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":"<=","value":".138","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":"<=","value":".347","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Aluminum, total recoverable","parameter_code":"01104","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Aluminum, total recoverable","parameter_code":"01104","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Aluminum, total recoverable","parameter_code":"01104","statistic":"monthly average","qualifier":"<=","value":".859","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Aluminum, total recoverable","parameter_code":"01104","statistic":"daily maximum","qualifier":"<=","value":"2.13","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"monthly average","qualifier":"<=","value":".047","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"daily maximum","qualifier":"<=","value":".123","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"monthly average","qualifier":"<=","value":".065","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":"<=","value":".136","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Toxicity, Acute","parameter_code":"TS000","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"tox acute","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"001","parameter":"Toxicity, Acute","parameter_code":"TS000","statistic":"daily maximum","qualifier":"<=","value":"10","unit":"tox acute","report_only":false,"enforceable":true,"months":"all","limit_set":"Coil Cleaning, Boiler Blowdown, Pretreatment of Coils, Cooling Tower Blowdown"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"60","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Chemical Oxygen Demand [COD]","parameter_code":"81017","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"002","parameter":"Chemical Oxygen Demand [COD]","parameter_code":"81017","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater Runoff"},{"outfall":"003","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"monthly average","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"89","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"60","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Hardness, total [as CaCO3]","parameter_code":"00900","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Hardness, total [as CaCO3]","parameter_code":"00900","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":"<=","value":".164","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":"<=","value":".164","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Noncontact Cooling Water, Cooling Tower Overflow, Stormwater Runoff"},{"outfall":"004","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"monthly average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Domestic Sanitary Wastewater"},{"outfall":"004","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"maximum weekly average","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Domestic Sanitary Wastewater"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Domestic Sanitary Wastewater"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Domestic Sanitary Wastewater"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Domestic Sanitary Wastewater"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Domestic Sanitary Wastewater"},{"outfall":"004","parameter":"E. coli","parameter_code":"51040","statistic":"30-day geometric mean","qualifier":"<=","value":"130","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"Domestic Sanitary Wastewater"},{"outfall":"004","parameter":"E. coli","parameter_code":"51040","statistic":"7-day geometric mean","qualifier":"<=","value":"240","unit":"#/100mL","report_only":false,"enforceable":true,"months":"all","limit_set":"Domestic Sanitary Wastewater"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"KY","sic":"4952"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=KY&sic=4952","url":"https://passage-data.com/api/v1/permits?state=KY&sic=4952"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"bod","place":"US-KY","medium":"water_discharge"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=bod&place=US-KY&medium=water_discharge","url":"https://passage-data.com/api/v1/limits?parameter=bod&place=US-KY&medium=water_discharge","page":"https://passage-data.com/limits/US-KY/bod"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"KY0092118"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=KY0092118"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"KY0092118"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=KY0092118"}]}