{"permit":"ING040166","name":"Prosperity Mine LLC","state":"IN","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/ING040166"},"about":[{"label":"What it is","text":"Bituminous Coal And Lignite - Surface (EPA's industry listing)"},{"label":"Where","text":"Petersburg, Indiana","href":"https://www.openstreetmap.org/?mlat=38.4925&mlon=-87.395#map=14/38.4925/-87.395"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Apr 30, 2029"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"IN","sic":"12","permits":38,"list":"https://passage-data.com/api/v1/permits?state=IN&sic=12","page":"https://passage-data.com/dmr/s/IN/12"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Duration","parameter_code":"50037","statistic":"monthly total","qualifier":null,"value":null,"unit":"d/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"001","parameter":"Precipitation volume","parameter_code":"79777","statistic":"monthly total","qualifier":null,"value":null,"unit":"in/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-I, CONGER CR, SUR 16"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Duration","parameter_code":"50037","statistic":"monthly total","qualifier":null,"value":null,"unit":"d/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"002","parameter":"Precipitation volume","parameter_code":"79777","statistic":"monthly total","qualifier":null,"value":null,"unit":"in/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-C, CONGER CR, SUR 13"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Duration","parameter_code":"50037","statistic":"monthly total","qualifier":null,"value":null,"unit":"d/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"003","parameter":"Precipitation volume","parameter_code":"79777","statistic":"monthly total","qualifier":null,"value":null,"unit":"in/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-F, CONGER CR, SUR 13"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Duration","parameter_code":"50037","statistic":"monthly total","qualifier":null,"value":null,"unit":"d/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"004","parameter":"Precipitation volume","parameter_code":"79777","statistic":"monthly total","qualifier":null,"value":null,"unit":"in/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-G, CONGER CR, SUR 13"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Manganese, total [as Mn]","parameter_code":"01055","statistic":"daily maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Aluminum, total [as Al]","parameter_code":"01105","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Duration","parameter_code":"50037","statistic":"monthly total","qualifier":null,"value":null,"unit":"d/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"005","parameter":"Precipitation volume","parameter_code":"79777","statistic":"monthly total","qualifier":null,"value":null,"unit":"in/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ACID, U-025 SB-J, CONGER CR"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Duration","parameter_code":"50037","statistic":"monthly total","qualifier":null,"value":null,"unit":"d/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"006","parameter":"Precipitation volume","parameter_code":"79777","statistic":"monthly total","qualifier":null,"value":null,"unit":"in/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-E, CONGER CR"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Duration","parameter_code":"50037","statistic":"monthly total","qualifier":null,"value":null,"unit":"d/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"007","parameter":"Precipitation volume","parameter_code":"79777","statistic":"monthly total","qualifier":null,"value":null,"unit":"in/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-K, CONGER CR"},{"outfall":"008","parameter":"pH","parameter_code":"00400","statistic":"daily minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"pH","parameter_code":"00400","statistic":"daily maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"35","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"70","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily average","qualifier":null,"value":null,"unit":"mL/L","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Solids, settleable","parameter_code":"00545","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mL/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily average","qualifier":"<=","value":"3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Duration","parameter_code":"50037","statistic":"monthly total","qualifier":null,"value":null,"unit":"d/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"},{"outfall":"008","parameter":"Precipitation volume","parameter_code":"79777","statistic":"monthly total","qualifier":null,"value":null,"unit":"in/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"ALK, U-025 SB-L, CONGER CR"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"IN","sic":"12"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=IN&sic=12","url":"https://passage-data.com/api/v1/permits?state=IN&sic=12","page":"https://passage-data.com/dmr/s/IN/12"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"ING040166"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=ING040166"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"ING040166"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=ING040166"}]}