{"permit":"IL0068705","name":"EMULSICOAT OF SOUTHERN ILLINOIS LLC","state":"IL","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/IL0068705"},"about":[{"label":"What it is","text":"Petroleum Bulk Stations & Terminals (EPA's industry listing)"},{"label":"Where","text":"Benton, Illinois","href":"https://www.openstreetmap.org/?mlat=37.985&mlon=-88.916111#map=14/37.985/-88.916111"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Feb 28, 2030"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"IL","sic":"51","permits":34,"list":"https://passage-data.com/api/v1/permits?state=IL&sic=51","page":"https://passage-data.com/dmr/s/IL/51"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WTR, BOILER BD,WTR SFTNR RECHARGE, AND SW"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WTR, BOILER BD,WTR SFTNR RECHARGE, AND SW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WTR, BOILER BD,WTR SFTNR RECHARGE, AND SW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"23","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WTR, BOILER BD,WTR SFTNR RECHARGE, AND SW"},{"outfall":"001","parameter":"Oil and grease","parameter_code":"03582","statistic":"30-day average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WTR, BOILER BD,WTR SFTNR RECHARGE, AND SW"},{"outfall":"001","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WTR, BOILER BD,WTR SFTNR RECHARGE, AND SW"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WTR, BOILER BD,WTR SFTNR RECHARGE, AND SW"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WTR, BOILER BD,WTR SFTNR RECHARGE, AND SW"},{"outfall":"A01","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Oil & Grease","parameter_code":"00556","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"30-day average","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"4","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Polynuclear Aromatic Hydrocarbons [PAHs]","parameter_code":"22456","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Benzene, ethylbenzene, toluene, xylene combination","parameter_code":"30383","statistic":"daily maximum","qualifier":"<=","value":".75","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Toluene","parameter_code":"34010","statistic":"30-day average","qualifier":"<=","value":".6","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Toluene","parameter_code":"34010","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Benzene","parameter_code":"34030","statistic":"daily maximum","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Ethylbenzene","parameter_code":"34371","statistic":"30-day average","qualifier":"<=","value":".014","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Ethylbenzene","parameter_code":"34371","statistic":"daily maximum","qualifier":"<=","value":".15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"30-day average","qualifier":"<=","value":".36","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"},{"outfall":"A01","parameter":"Xylene [mix of m+o+p]","parameter_code":"81551","statistic":"daily maximum","qualifier":"<=","value":".92","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"HYDROSTATIC TEST WATER"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"IL","sic":"51"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=IL&sic=51","url":"https://passage-data.com/api/v1/permits?state=IL&sic=51","page":"https://passage-data.com/dmr/s/IL/51"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"IL0068705"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=IL0068705"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"IL0068705"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=IL0068705"}]}