{"permit":"IL0002241","name":"KINCAID GENERATION LLC","state":"IL","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/IL0002241"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Kincaid, Illinois","href":"https://www.openstreetmap.org/?mlat=39.592222&mlon=-89.496389#map=14/39.592222/-89.496389"},{"label":"Last 12 months","text":"Over a limit once, last in December 2025 (Solids, total suspended). 15 of 82 reports filed late"},{"label":"Permit","text":"Expired Aug 31, 2026; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2026-03-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/IL0002241#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"IL","sic":"4911","permits":45,"list":"https://passage-data.com/api/v1/permits?state=IL&sic=4911","page":"https://passage-data.com/dmr/s/IL/4911"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":1,"over_by":[["Solids, total suspended",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Solids, total suspended","times":1,"find_limits":{"parameter":"total suspended solids","place":"US-IL","medium":"water_discharge"},"get":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-IL&medium=water_discharge"}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily average","qualifier":"<=","value":"99","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"111","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"monthly minimum","qualifier":">=","value":"6.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"monthly maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"001","parameter":"Temperature, length of excursion","parameter_code":"45600","statistic":"monthly maximum","qualifier":null,"value":null,"unit":"hr/mo","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"001","parameter":"Temperature, length of excursion","parameter_code":"45600","statistic":"total","qualifier":"<=","value":"613","unit":"hr/12mo","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"001","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"CONDENSER COOLING WTR, HOUSE SVC WTR, AND BOILER DRAINS"},{"outfall":"B01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WW TREATMENT PLANT EFFLUENT"},{"outfall":"B01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WW TREATMENT PLANT EFFLUENT"},{"outfall":"B01","parameter":"Oil and grease","parameter_code":"03582","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WW TREATMENT PLANT EFFLUENT"},{"outfall":"B01","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"WW TREATMENT PLANT EFFLUENT"},{"outfall":"B01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"WW TREATMENT PLANT EFFLUENT"},{"outfall":"B01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"WW TREATMENT PLANT EFFLUENT"},{"outfall":"C01","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"30-day average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STP EFFLUENT"},{"outfall":"C01","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"60","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STP EFFLUENT"},{"outfall":"C01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"30-day average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STP EFFLUENT"},{"outfall":"C01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"60","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STP EFFLUENT"},{"outfall":"C01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"STP EFFLUENT"},{"outfall":"C01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"STP EFFLUENT"},{"outfall":"C01","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":"<=","value":".05","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"STP EFFLUENT"},{"outfall":"C01","parameter":"Coliform, fecal general","parameter_code":"74055","statistic":"daily maximum","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"STP EFFLUENT"},{"outfall":"D01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DEMINERALIZER REGENERANT WASTES"},{"outfall":"D01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DEMINERALIZER REGENERANT WASTES"},{"outfall":"D01","parameter":"Oil and grease","parameter_code":"03582","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DEMINERALIZER REGENERANT WASTES"},{"outfall":"D01","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"DEMINERALIZER REGENERANT WASTES"},{"outfall":"D01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"DEMINERALIZER REGENERANT WASTES"},{"outfall":"D01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"DEMINERALIZER REGENERANT WASTES"},{"outfall":"E01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ASH SLUICE WTR RECYCLE SYSTEM EMERGENCY OVERFLOW"},{"outfall":"E01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ASH SLUICE WTR RECYCLE SYSTEM EMERGENCY OVERFLOW"},{"outfall":"E01","parameter":"Oil and grease","parameter_code":"03582","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ASH SLUICE WTR RECYCLE SYSTEM EMERGENCY OVERFLOW"},{"outfall":"E01","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"ASH SLUICE WTR RECYCLE SYSTEM EMERGENCY OVERFLOW"},{"outfall":"E01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ASH SLUICE WTR RECYCLE SYSTEM EMERGENCY OVERFLOW"},{"outfall":"E01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"ASH SLUICE WTR RECYCLE SYSTEM EMERGENCY OVERFLOW"},{"outfall":"F01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SWITCHYARD AREA RUNOFF"},{"outfall":"F01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SWITCHYARD AREA RUNOFF"},{"outfall":"H01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"30-day average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"30-day average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"30-day average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Oil and grease","parameter_code":"03582","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"H01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"METAL CLEANING WASTES"},{"outfall":"I01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEE PERMIT"},{"outfall":"I01","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEE PERMIT"},{"outfall":"I01","parameter":"Oil and grease","parameter_code":"03582","statistic":"30-day average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEE PERMIT"},{"outfall":"I01","parameter":"Oil and grease","parameter_code":"03582","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"SEE PERMIT"},{"outfall":"I01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SEE PERMIT"},{"outfall":"I01","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"SEE PERMIT"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"IL","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=IL&sic=4911","url":"https://passage-data.com/api/v1/permits?state=IL&sic=4911","page":"https://passage-data.com/dmr/s/IL/4911"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"total suspended solids","place":"US-IL","medium":"water_discharge"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-IL&medium=water_discharge","url":"https://passage-data.com/api/v1/limits?parameter=total+suspended+solids&place=US-IL&medium=water_discharge","page":"https://passage-data.com/limits/US-IL/total-suspended-solids"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"IL0002241"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=IL0002241"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"IL0002241"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=IL0002241"}]}