{"permit":"HI0021939","name":"HONOLULU MARINE LLC","state":"HI","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/HI0021939"},"about":[{"label":"What it is","text":"Industrial or other facility"},{"label":"Where","text":"Unknown, Hawaii","href":"https://www.openstreetmap.org/?mlat=21.310923&mlon=-158.103352#map=14/21.310923/-158.103352"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Nov 30, 2027"}],"renewal_due":null,"renewal_check":{"offered_because":"application_due_within_18_months","application_due":"2027-06-03","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/HI0021939#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":null,"limits_from_version":null,"record":{"last_filed":"2026-06-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"001","parameter":"Acenaphthylene","parameter_code":"34200","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Acenaphthene","parameter_code":"34205","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Anthracene","parameter_code":"34220","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Benzo[b]fluoranthene","parameter_code":"34230","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Benzo[k]fluoranthene","parameter_code":"34242","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Benzo[a]pyrene","parameter_code":"34247","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Chrysene","parameter_code":"34320","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Fluoranthene","parameter_code":"34376","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Fluorene","parameter_code":"34381","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Indeno[1,2,3-cd]pyrene","parameter_code":"34403","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Phenanthrene","parameter_code":"34461","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Pyrene","parameter_code":"34469","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Benzo[ghi]perylene","parameter_code":"34521","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Benzo[a]anthracene","parameter_code":"34526","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Dibenz[a,h]anthracene","parameter_code":"34556","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"001","parameter":"Chemical Oxygen Demand [COD]","parameter_code":"81017","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"001W","parameter":"Arsenic, total recoverable","parameter_code":"0978A","statistic":"maximum","qualifier":"<=","value":"12735","unit":"ug/ft2","report_only":false,"enforceable":false,"months":"all","limit_set":"Quarterly Wipe Test Samples"},{"outfall":"001W","parameter":"Zinc, total recoverable","parameter_code":"1094A","statistic":"maximum","qualifier":"<=","value":"32157","unit":"ug/ft2","report_only":false,"enforceable":false,"months":"all","limit_set":"Quarterly Wipe Test Samples"},{"outfall":"001W","parameter":"Cadmium, total recoverable [mass/area]","parameter_code":"1113R","statistic":"maximum","qualifier":"<=","value":"3310","unit":"ug/ft2","report_only":false,"enforceable":false,"months":"all","limit_set":"Quarterly Wipe Test Samples"},{"outfall":"001W","parameter":"Lead, total recoverable","parameter_code":"1114A","statistic":"maximum","qualifier":"<=","value":"2080","unit":"ug/ft2","report_only":false,"enforceable":false,"months":"all","limit_set":"Quarterly Wipe Test Samples"},{"outfall":"001W","parameter":"Copper, total recoverable","parameter_code":"1119A","statistic":"maximum","qualifier":"<=","value":"1231","unit":"ug/ft2","report_only":false,"enforceable":false,"months":"all","limit_set":"Quarterly Wipe Test Samples"},{"outfall":"001W","parameter":"Tributyltin, total recoverable","parameter_code":"5151A","statistic":"maximum","qualifier":"<=","value":"4","unit":"ug/ft2","report_only":false,"enforceable":false,"months":"all","limit_set":"Quarterly Wipe Test Samples"},{"outfall":"001W","parameter":"Mercury, total recoverable","parameter_code":"7190A","statistic":"maximum","qualifier":"<=","value":"10","unit":"ug/ft2","report_only":false,"enforceable":false,"months":"all","limit_set":"Quarterly Wipe Test Samples"},{"outfall":"001W","parameter":"Chromium, hexavalent tot recoverable","parameter_code":"8247A","statistic":"maximum","qualifier":"<=","value":"17811","unit":"ug/ft2","report_only":false,"enforceable":false,"months":"all","limit_set":"Quarterly Wipe Test Samples"},{"outfall":"002","parameter":"Flow rate","parameter_code":"00056","statistic":"daily maximum","qualifier":null,"value":null,"unit":"gal/min","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"},{"outfall":"002","parameter":"Acenaphthylene","parameter_code":"34200","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Acenaphthene","parameter_code":"34205","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Anthracene","parameter_code":"34220","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Benzo[b]fluoranthene","parameter_code":"34230","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Benzo[k]fluoranthene","parameter_code":"34242","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Benzo[a]pyrene","parameter_code":"34247","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Chrysene","parameter_code":"34320","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Fluoranthene","parameter_code":"34376","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Fluorene","parameter_code":"34381","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Indeno[1,2,3-cd]pyrene","parameter_code":"34403","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Phenanthrene","parameter_code":"34461","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Pyrene","parameter_code":"34469","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Benzo[ghi]perylene","parameter_code":"34521","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Benzo[a]anthracene","parameter_code":"34526","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Dibenz[a,h]anthracene","parameter_code":"34556","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Naphthalene","parameter_code":"34696","statistic":"maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"002 / semiannual stormwater runoff associated with industrial activities"},{"outfall":"002","parameter":"Chemical Oxygen Demand [COD]","parameter_code":"81017","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater runoff associated with industrial activity - quarterly"}],"next":[{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"HI0021939"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=HI0021939"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"HI0021939"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=HI0021939"}]}