{"permit":"GA0026786","name":"Southern Nuclear Operating Company","state":"GA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/GA0026786"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Waynesboro, Georgia","href":"https://www.openstreetmap.org/?mlat=33&mlon=-82#map=14/33/-82"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Nov 30, 2030"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"GA","sic":"4911","permits":31,"list":"https://passage-data.com/api/v1/permits?state=GA&sic=4911","page":"https://passage-data.com/dmr/s/GA/4911"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"upcoming":[{"parameter":"E. coli","outfall":"006","limit":126,"unit":"#/100mL","statistic":"daily average","statistic_code":"DB","begin":"2026-12-01","kind":"new","now":null},{"parameter":"E. coli","outfall":"006","limit":410,"unit":"#/100mL","statistic":"daily maximum","statistic_code":"DD","begin":"2026-12-01","kind":"new","now":null},{"parameter":"E. coli","outfall":"015","limit":410,"unit":"#/100mL","statistic":"daily maximum","statistic_code":"DD","begin":"2026-12-01","kind":"new","now":{"median":275.5,"n":9},"times_limit":0.672},{"parameter":"E. coli","outfall":"015","limit":126,"unit":"#/100mL","statistic":"daily geometric mean","statistic_code":"DM","begin":"2026-12-01","kind":"new","now":{"median":29.2,"n":9},"times_limit":0.232}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrogen, organic total [as N]","parameter_code":"00605","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrogen, organic total [as N]","parameter_code":"00605","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Temp. diff. between up/down stream deg. F","parameter_code":"03772","statistic":"daily maximum","qualifier":"<=","value":"5","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Phosphate, ortho [as P]","parameter_code":"04175","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Phosphate, ortho [as P]","parameter_code":"04175","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".02","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".3","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"E. coli","parameter_code":"51040","statistic":"daily geometric mean","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"E. coli","parameter_code":"51040","statistic":"daily maximum","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia","parameter_code":"TOP3B","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas","parameter_code":"TOP6C","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia","parameter_code":"TPP3B","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas","parameter_code":"TPP6C","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge"},{"outfall":"002","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"002","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"003","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Cooling Tower Blowdown"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Waste Water Retention Basin"},{"outfall":"004","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Waste Water Retention Basin"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Waste Water Retention Basin"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Waste Water Retention Basin"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Waste Water Retention Basin"},{"outfall":"004","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Waste Water Retention Basin"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Waste Water Retention Basin"},{"outfall":"005","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Waste Water Retention Basin"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Waste Water Retention Basin"},{"outfall":"005","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Waste Water Retention Basin"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Waste Water Retention Basin"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Waste Water Retention Basin"},{"outfall":"006","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant Emergency Overflow"},{"outfall":"006","parameter":"BOD, 5-day, 20 deg. C","parameter_code":"00310","statistic":"daily maximum","qualifier":"<=","value":"45","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant Emergency Overflow"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant Emergency Overflow"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant Emergency Overflow"},{"outfall":"006","parameter":"E. coli","parameter_code":"51040","statistic":"daily geometric mean","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant Emergency Overflow"},{"outfall":"006","parameter":"E. coli","parameter_code":"51040","statistic":"daily maximum","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant Emergency Overflow"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Liquid Radwaste Systems Discharge"},{"outfall":"007","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Liquid Radwaste Systems Discharge"},{"outfall":"007","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Liquid Radwaste Systems Discharge"},{"outfall":"007","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Liquid Radwaste Systems Discharge"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Liquid Radwaste Systems Discharge"},{"outfall":"007","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Liquid Radwaste Systems Discharge"},{"outfall":"008","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Liquid Radwaste Systems Discharge"},{"outfall":"008","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Liquid Radwaste Systems Discharge"},{"outfall":"008","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Liquid Radwaste Systems Discharge"},{"outfall":"008","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Liquid Radwaste Systems Discharge"},{"outfall":"008","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Liquid Radwaste Systems Discharge"},{"outfall":"008","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Liquid Radwaste Systems Discharge"},{"outfall":"009","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"009","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Units 1 & 2 Nuclear Service Cooling Tower Blowdown"},{"outfall":"013","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Unit 1 Emergency Overflow, Sewage Treatment Plant Emergency Overflow, and"},{"outfall":"013","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Unit 1 Emergency Overflow, Sewage Treatment Plant Emergency Overflow, and"},{"outfall":"013","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Unit 1 Emergency Overflow, Sewage Treatment Plant Emergency Overflow, and"},{"outfall":"013","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Unit 1 Emergency Overflow, Sewage Treatment Plant Emergency Overflow, and"},{"outfall":"013","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Unit 1 Emergency Overflow, Sewage Treatment Plant Emergency Overflow, and"},{"outfall":"013","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Unit 1 Emergency Overflow, Sewage Treatment Plant Emergency Overflow, and"},{"outfall":"013","parameter":"E. coli","parameter_code":"51040","statistic":"daily geometric mean","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Unit 1 Emergency Overflow, Sewage Treatment Plant Emergency Overflow, and"},{"outfall":"013","parameter":"E. coli","parameter_code":"51040","statistic":"daily maximum","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Unit 1 Emergency Overflow, Sewage Treatment Plant Emergency Overflow, and"},{"outfall":"014","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Units 1&2 Emergency Overflow and Allowable Non-Stormwater Discharges"},{"outfall":"014","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Units 1&2 Emergency Overflow and Allowable Non-Stormwater Discharges"},{"outfall":"014","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Units 1&2 Emergency Overflow and Allowable Non-Stormwater Discharges"},{"outfall":"014","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Units 1&2 Emergency Overflow and Allowable Non-Stormwater Discharges"},{"outfall":"014","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Units 1&2 Emergency Overflow and Allowable Non-Stormwater Discharges"},{"outfall":"014","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Stormwater commingled with Units 1&2 Emergency Overflow and Allowable Non-Stormwater Discharges"},{"outfall":"015","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant"},{"outfall":"015","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant"},{"outfall":"015","parameter":"E. coli","parameter_code":"51040","statistic":"daily geometric mean","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant"},{"outfall":"015","parameter":"E. coli","parameter_code":"51040","statistic":"daily maximum","qualifier":null,"value":null,"unit":"#/100mL","report_only":true,"enforceable":true,"months":"all","limit_set":"Sewage Treatment Plant"},{"outfall":"02A","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"02A","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"},{"outfall":"03A","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Emergency Overflows to Storm Drains"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"GA","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=GA&sic=4911","url":"https://passage-data.com/api/v1/permits?state=GA&sic=4911","page":"https://passage-data.com/dmr/s/GA/4911"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"GA0026786"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=GA0026786"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"GA0026786"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=GA0026786"}]}