{"permit":"GA0001473","name":"Georgia Power Company","state":"GA","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/GA0001473"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Newnan, Georgia","href":"https://www.openstreetmap.org/?mlat=33.462079&mlon=-84.897855#map=14/33.462079/-84.897855"},{"label":"Last 12 months","text":"Over a limit 3 times, last in November 2025 (Chlorine, free available; Chlorine, total residual [dsg. time])"},{"label":"Permit","text":"In force until Sep 30, 2030"}],"renewal_due":null,"renewal_check":null,"sector":{"state":"GA","sic":"4911","permits":31,"list":"https://passage-data.com/api/v1/permits?state=GA&sic=4911","page":"https://passage-data.com/dmr/s/GA/4911"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":3,"over_by":[["Chlorine, free available",2],["Chlorine, total residual [dsg. time]",1]],"window":["2025-10-01","2026-09-30"]},"over_limits":[{"parameter":"Chlorine, free available","times":2,"find_limits":{"parameter":"chlorine","place":"US-GA","medium":"surface_water"},"get":"https://passage-data.com/api/v1/limits?parameter=chlorine&place=US-GA&medium=surface_water"}],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"daily maximum","qualifier":"<=","value":"90","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrogen, organic total [as N]","parameter_code":"00605","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrogen, organic total [as N]","parameter_code":"00605","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Phosphate, ortho [as P]","parameter_code":"04175","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Phosphate, ortho [as P]","parameter_code":"04175","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia","parameter_code":"TOP3B","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas","parameter_code":"TOP6C","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia","parameter_code":"TPP3B","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"001","parameter":"NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas","parameter_code":"TPP6C","statistic":"minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"Final Plant Discharge commingled with Stormwater"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrogen, total [as N]","parameter_code":"00600","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrogen, organic total [as N]","parameter_code":"00605","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrogen, organic total [as N]","parameter_code":"00605","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nitrite + Nitrate total [as N]","parameter_code":"00630","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Phosphorus, total [as P]","parameter_code":"00665","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Thallium, total [as Tl]","parameter_code":"01059","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Thallium, total [as Tl]","parameter_code":"01059","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Antimony, total [as Sb]","parameter_code":"01097","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Antimony, total [as Sb]","parameter_code":"01097","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Selenium, total [as Se]","parameter_code":"01147","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Phosphate, ortho [as P]","parameter_code":"04175","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Phosphate, ortho [as P]","parameter_code":"04175","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Solids, total dissolved [TDS]","parameter_code":"70296","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Solids, total dissolved [TDS]","parameter_code":"70296","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"002","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Service Water Pond Emergency Overflow/Drain commingled with Stormwater and Groundwater"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"North Intake Screen Backwash"},{"outfall":"005","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"North Intake Screen Backwash"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"South Intake Backwash and River Pump Strainer Discharge"},{"outfall":"006","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"South Intake Backwash and River Pump Strainer Discharge"},{"outfall":"03E","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Waste commingled with Units 6&7 Cooling Tower Overflow and Drain"},{"outfall":"03E","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Waste commingled with Units 6&7 Cooling Tower Overflow and Drain"},{"outfall":"03E","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Waste commingled with Units 6&7 Cooling Tower Overflow and Drain"},{"outfall":"03E","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Low Volume Waste commingled with Units 6&7 Cooling Tower Overflow and Drain"},{"outfall":"03E","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume Waste commingled with Units 6&7 Cooling Tower Overflow and Drain"},{"outfall":"03E","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Low Volume Waste commingled with Units 6&7 Cooling Tower Overflow and Drain"},{"outfall":"03F","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03F","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown"},{"outfall":"03G","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03G","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 6 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03H","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03H","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown"},{"outfall":"03I","parameter":"Chlorine, total residual [dsg. time]","parameter_code":"00208","statistic":"daily maximum","qualifier":"<=","value":"120","unit":"min/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily average","qualifier":"<=","value":".2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03I","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 7 Cooling Tower Blowdown Overflow and Drain"},{"outfall":"03J","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily average","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily average","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily average","qualifier":"<=","value":"8","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Arsenic, total [as As]","parameter_code":"01002","statistic":"daily maximum","qualifier":"<=","value":"11","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily average","qualifier":"<=","value":"356","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"},{"outfall":"03J","parameter":"Mercury, total [as Hg]","parameter_code":"71900","statistic":"daily maximum","qualifier":"<=","value":"788","unit":"ng/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Treatment System Discharge (AMA & AEM discharges)"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"GA","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=GA&sic=4911","url":"https://passage-data.com/api/v1/permits?state=GA&sic=4911","page":"https://passage-data.com/dmr/s/GA/4911"},{"tool":"find_limits","says":"What do the rules say about what it went over on? find_limits gives the cited state and federal limits for it, each with its rule; `get` is the address to fetch, and `over_limits` holds one for each parameter.","arguments":{"parameter":"chlorine","place":"US-GA","medium":"surface_water"},"needs":{},"get":"https://passage-data.com/api/v1/limits?parameter=chlorine&place=US-GA&medium=surface_water","url":"https://passage-data.com/api/v1/limits?parameter=chlorine&place=US-GA&medium=surface_water","page":"https://passage-data.com/limits/US-GA/chlorine"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"GA0001473"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=GA0001473"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"GA0001473"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=GA0001473"}]}