{"permit":"CT0030821","name":"FIRSTLIGHT CT HOUSATONIC LLC","state":"CT","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/CT0030821"},"about":[{"label":"What it is","text":"Industrial or other facility"},{"label":"Where","text":"Monroe, Connecticut","href":"https://www.openstreetmap.org/?mlat=41.382487&mlon=-73.17109#map=14/41.382487/-73.17109"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Apr 30, 2030"}],"renewal_due":null,"renewal_check":null,"sector":null,"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Non-contact cooling water from Turbines 1-4"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6.8","unit":"SU","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Non-contact cooling water from Turbines 1-4"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Non-contact cooling water from Turbines 1-4"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Non-contact cooling water from Turbines 1-4"},{"outfall":"001","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"18920","unit":"gal/d","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Non-contact cooling water from Turbines 1-4"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6.8","unit":"SU","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Emergency pump out water from Turbines 1 and 2"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Emergency pump out water from Turbines 1 and 2"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Emergency pump out water from Turbines 1 and 2"},{"outfall":"002","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"417600","unit":"gal/d","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Emergency pump out water from Turbines 1 and 2"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6.8","unit":"SU","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Emergency pump out water from Turbines 3 and 4"},{"outfall":"003","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Emergency pump out water from Turbines 3 and 4"},{"outfall":"003","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Emergency pump out water from Turbines 3 and 4"},{"outfall":"003","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"417600","unit":"gal/d","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Emergency pump out water from Turbines 3 and 4"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6.8","unit":"SU","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Leakage from Turbine 4"},{"outfall":"004","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"8.5","unit":"SU","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Leakage from Turbine 4"},{"outfall":"004","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Leakage from Turbine 4"},{"outfall":"004","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"12","unit":"gal/d","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Leakage from Turbine 4"},{"outfall":"005","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"36","unit":"gal/d","report_only":false,"enforceable":true,"months":["MAR","SEP"],"limit_set":"Leakage from Turbines 1-3 through the tailrace"}],"next":[{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"CT0030821"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=CT0030821"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"CT0030821"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=CT0030821"}]}