{"permit":"CT0003263","name":"MILLSTONE POWER STATION","state":"CT","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/CT0003263"},"about":[{"label":"What it is","text":"Electric Services (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Waterford, Connecticut","href":"https://www.openstreetmap.org/?mlat=41.308611&mlon=-72.166389#map=14/41.308611/-72.166389"},{"label":"Last 12 months","text":"No values over a limit. 2 required values not reported"},{"label":"Permit","text":"Expired Aug 31, 2015; its limits still apply until a new permit is issued, and EPA still expects the reports"}],"renewal_due":null,"renewal_check":{"offered_because":"permit_expired","application_due":"2015-03-04","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/CT0003263#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"CT","sic":"4911","permits":12,"list":"https://passage-data.com/api/v1/permits?state=CT&sic=4911","page":"https://passage-data.com/dmr/s/CT/4911"},"limits_from_version":null,"record":{"last_filed":"2026-08-31","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"instantaneous maximum","qualifier":"<=","value":"105","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Temperature, water deg. fahrenheit","parameter_code":"00011","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"deg F","report_only":true,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":"<=","value":"2190","unit":"MGD","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Turbidity","parameter_code":"00070","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Turbidity","parameter_code":"00070","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"NTU","report_only":true,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"2255.625","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Turbidity, increase over background","parameter_code":"52350","statistic":"instantaneous maximum","qualifier":"<=","value":"5","unit":"NTU","report_only":false,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"32","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"41","unit":"deg F","report_only":false,"enforceable":true,"months":["APR","MAY"],"limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"44","unit":"deg F","report_only":false,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"pH, maximum","parameter_code":"61941","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"pH, minimum","parameter_code":"61942","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"2255.625","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Noael Static 48Hr Acute Mysid. Bahia","parameter_code":"TDA3E","statistic":"daily minimum","qualifier":">=","value":"90","unit":"%","report_only":false,"enforceable":true,"months":["JAN","APR","JUL","OCT"],"limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"Noael Static 48Hr Acute Mysid. Bahia","parameter_code":"TDA3E","statistic":"daily minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":["FEB","MAR","MAY","JUN","AUG","SEP","NOV","DEC"],"limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"NOAEL Static 48Hr Acute Cyprinodon variegatus","parameter_code":"TDA6A","statistic":"daily minimum","qualifier":">=","value":"90","unit":"%","report_only":false,"enforceable":true,"months":["JAN","APR","JUL","OCT"],"limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001","parameter":"NOAEL Static 48Hr Acute Cyprinodon variegatus","parameter_code":"TDA6A","statistic":"daily minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":["FEB","MAR","MAY","JUN","AUG","SEP","NOV","DEC"],"limit_set":"Discharge Points at Quarry Cut."},{"outfall":"001A","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"instantaneous maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Dichlorodifluoromethane","parameter_code":"34668","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Chlorodifluoromethane","parameter_code":"45028","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"40000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"40000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001A","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 1 Miscellaneous Decommissioning Wasterwaters from Sumps."},{"outfall":"001B","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Auxiliary Heat Exchanger."},{"outfall":"001B","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condenser Hotwell Discharge during start-up."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Aerated Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Coolant Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condenser Hotwell Discharge during start-up."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Aerated Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Coolant Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condenser Hotwell Discharge during start-up."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Aerated Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Coolant Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Nitrogen, nitrite total [as N]","parameter_code":"00615","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Nitrogen, nitrite total [as N]","parameter_code":"00615","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Nitrogen, nitrate total [as N]","parameter_code":"00620","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Nitrogen, nitrate total [as N]","parameter_code":"00620","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"monthly average","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condenser Hotwell Discharge during start-up."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Closed cooling water system drainage."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Aerated Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Coolant Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Dichlorodifluoromethane","parameter_code":"34668","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Closed cooling water system drainage."},{"outfall":"001B","parameter":"Chlorodifluoromethane","parameter_code":"45028","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Closed cooling water system drainage."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"250000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condenser Hotwell Discharge during start-up."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"30000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Closed cooling water system drainage."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"150000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"150000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"844.652","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"15000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Aerated Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"60000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"90000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Coolant Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"51.84","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Auxiliary Heat Exchanger."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"75000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"280000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"1.44","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"instantaneous minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Auxiliary Heat Exchanger."},{"outfall":"001B","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"instantaneous maximum","qualifier":"<=","value":".25","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"instantaneous maximum","qualifier":"<=","value":".25","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Auxiliary Heat Exchanger."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condenser Hotwell Discharge during start-up."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Closed cooling water system drainage."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Aerated Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Coolant Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"32","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"46","unit":"deg F","report_only":false,"enforceable":true,"months":["APR","MAY"],"limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"44","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"48","unit":"deg F","report_only":false,"enforceable":true,"months":["APR","MAY"],"limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"38","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"pH, maximum","parameter_code":"61941","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"pH, minimum","parameter_code":"61942","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"844.652","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"51.84","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 Auxiliary Heat Exchanger."},{"outfall":"001B","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"1.44","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condenser Hotwell Discharge during start-up."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Closed cooling water system drainage."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Condenser non-contact cooling water-service water, intake pump seal-lubricating water."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Aerated Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Coolant Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":"<=","value":"37.5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":"<=","value":"125","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam generator secondary side wet layup discharge."},{"outfall":"001B","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condenser Hotwell Discharge during start-up."},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 -16  inch standpipe discharge to the circulating water tunnel ."},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Service water drainage and incidental system leakage from the Reactor building."},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Aerated Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Steam generator chemical cleaning and chemical decontamination wastewater discharge."},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 Coolant Waste Monitor Tank discharge."},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2  Condensate Polisher Regeneration Wastewater Neutralization tank discharge."},{"outfall":"001B","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Steam Generator blowdown tanks and blowdown generated during open cycle"},{"outfall":"001C","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of the Unit 3 Auxiliary boiler blowdown including continuous discharge."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"SU","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Condenser Hotwell wastewater discharged directly from the  condensate pump discharge."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of the Unit 3 Auxiliary boiler blowdown including continuous discharge."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Condenser Hotwell wastewater discharged directly from the  condensate pump discharge."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of the Unit 3 Auxiliary boiler blowdown including continuous discharge."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Condenser Hotwell wastewater discharged directly from the  condensate pump discharge."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"Oil & Grease","parameter_code":"00556","statistic":"instantaneous maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"kg/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Nitrogen, nitrite total [as N]","parameter_code":"00615","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Nitrogen, nitrite total [as N]","parameter_code":"00615","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Nitrogen, nitrate total [as N]","parameter_code":"00620","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Nitrogen, nitrate total [as N]","parameter_code":"00620","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Nitrogen, Kjeldahl, total [as N]","parameter_code":"00625","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"monthly average","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Cadmium, total [as Cd]","parameter_code":"01027","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Chromium, total [as Cr]","parameter_code":"01034","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Copper, total [as Cu]","parameter_code":"01042","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"daily maximum","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Iron, total [as Fe]","parameter_code":"01045","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"monthly average","qualifier":"<=","value":".1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Lead, total [as Pb]","parameter_code":"01051","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of the Unit 3 Auxiliary boiler blowdown including continuous discharge."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Condenser Hotwell wastewater discharged directly from the  condensate pump discharge."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"Molybdenum, total [as Mo]","parameter_code":"01062","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Nickel, total [as Ni]","parameter_code":"01067","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"monthly average","qualifier":"<=","value":"1","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"daily maximum","qualifier":"<=","value":"2","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of the Unit 3 Auxiliary boiler blowdown including continuous discharge."},{"outfall":"001C","parameter":"Zinc, total [as Zn]","parameter_code":"01092","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Dichlorodifluoromethane","parameter_code":"34668","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"Chlorodifluoromethane","parameter_code":"45028","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"86.4","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Service water from auxiliary heat exchangers during start up."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"1410.933","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"1.4","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"60000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"576000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"72000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of the Unit 3 Auxiliary boiler blowdown including continuous discharge."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"20000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"250000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Condenser Hotwell wastewater discharged directly from the  condensate pump discharge."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"80000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"30000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"50000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"75000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"instantaneous minimum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Service water from auxiliary heat exchangers during start up."},{"outfall":"001C","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"instantaneous maximum","qualifier":"<=","value":".25","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Service water from auxiliary heat exchangers during start up."},{"outfall":"001C","parameter":"Chlorine, free available","parameter_code":"50064","statistic":"instantaneous maximum","qualifier":"<=","value":".25","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of the Unit 3 Auxiliary boiler blowdown including continuous discharge."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Condenser Hotwell wastewater discharged directly from the  condensate pump discharge."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"Ethanolamine","parameter_code":"51658","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"Dimethyldithiocarbamate","parameter_code":"51659","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"Dimethyldithiocarbamate","parameter_code":"51659","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"28","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"38","unit":"deg F","report_only":false,"enforceable":true,"months":["APR","MAY"],"limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"30","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"40","unit":"deg F","report_only":false,"enforceable":true,"months":["APR","MAY"],"limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Temp. diff. between intake and discharge","parameter_code":"61576","statistic":"instantaneous maximum","qualifier":"<=","value":"36","unit":"deg F","report_only":false,"enforceable":true,"months":["JAN","FEB","MAR","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"pH, maximum","parameter_code":"61941","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"pH, minimum","parameter_code":"61942","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"86.4","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Service water from auxiliary heat exchangers during start up."},{"outfall":"001C","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"1410.933","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"1.4","unit":"MGD","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Dimethylamine","parameter_code":"77003","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Dimethylamine","parameter_code":"77003","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":"<=","value":"37.5","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Discharge non-contact cooling water."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":"<=","value":"125","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator (4) wet lay up drainage for maintenance."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Intermittent discharge of the Unit 3 Auxiliary boiler blowdown including continuous discharge."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Condenser Hotwell wastewater discharged directly from the  condensate pump discharge."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Closed cooling water system drainage."},{"outfall":"001C","parameter":"Hydrazine","parameter_code":"81313","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"001C","parameter":"Boron, total","parameter_code":"82057","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Condensate polishing facility discharge."},{"outfall":"001C","parameter":"Boron, total","parameter_code":"82057","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Steam generator chemical cleaning and chemical decontaminiation wastewater."},{"outfall":"001C","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Steam generator blowdown tanks and blowdown generated during open cycle."},{"outfall":"001C","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Low level radiation waste drain tank discharge."},{"outfall":"001C","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Condenser Hotwell wastewater discharged directly from the  condensate pump discharge."},{"outfall":"001C","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Secondary system wet lay up drainage."},{"outfall":"001C","parameter":"Boron, total","parameter_code":"82057","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  3 Radiation waste test tank discharge."},{"outfall":"003","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Screen washwater discharge, including non-chlorinated sea water."},{"outfall":"003","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN","JUL"],"limit_set":"Unit 2 Screen washwater discharge, including non-chlorinated sea water."},{"outfall":"003","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit 2 Screen washwater discharge, including non-chlorinated sea water."},{"outfall":"003A","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 2 Fish and invertebrate return trough discharge including wastewaters."},{"outfall":"003A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN","JUL"],"limit_set":"Unit 2 Fish and invertebrate return trough discharge including wastewaters."},{"outfall":"003A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit 2 Fish and invertebrate return trough discharge including wastewaters."},{"outfall":"004","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit 3 Screen washwater discharge including debris conveyor and backside refuse trough."},{"outfall":"004","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN","JUL"],"limit_set":"Unit 3 Screen washwater discharge including debris conveyor and backside refuse trough."},{"outfall":"004","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Unit 3 Screen washwater discharge including debris conveyor and backside refuse trough."},{"outfall":"005","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"005","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"006","parameter":"Flow rate","parameter_code":"00056","statistic":"monthly average","qualifier":"<=","value":"216000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"pH","parameter_code":"00400","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"20","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"30","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Nitrogen, ammonia total [as N]","parameter_code":"00610","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Flow, maximum during 24 hr period","parameter_code":"50047","statistic":"daily maximum","qualifier":"<=","value":"432000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Ethanolamine","parameter_code":"51658","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Ethanolamine","parameter_code":"51658","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Surfactants, anionic ","parameter_code":"51660","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Surfactants, anionic ","parameter_code":"51660","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"pH, maximum","parameter_code":"61941","statistic":"instantaneous maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"pH, minimum","parameter_code":"61942","statistic":"instantaneous minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Flow","parameter_code":"74076","statistic":"monthly average","qualifier":null,"value":null,"unit":"gal/d","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Flow","parameter_code":"74076","statistic":"daily maximum","qualifier":"<=","value":"432000","unit":"gal/d","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Hydrazine","parameter_code":"81313","statistic":"monthly average","qualifier":"<=","value":"50","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Hydrazine","parameter_code":"81313","statistic":"daily maximum","qualifier":"<=","value":"100","unit":"ug/L","report_only":false,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Boron, total","parameter_code":"82057","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"Boron, total","parameter_code":"82057","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"LC50 Static 48Hr Acute Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TAA3E","statistic":"daily minimum","qualifier":">=","value":"100","unit":"%","report_only":false,"enforceable":true,"months":["JAN","APR","JUL","OCT"],"limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"LC50 Static 48Hr Acute Americamysis bahia (formerly Mysidopsis bahia)","parameter_code":"TAA3E","statistic":"daily minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":["FEB","MAR","MAY","JUN","AUG","SEP","NOV","DEC"],"limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"LC50 Static 48Hr Acute Cyprinodon variegatus","parameter_code":"TAA6A","statistic":"daily minimum","qualifier":">=","value":"100","unit":"%","report_only":false,"enforceable":true,"months":["JAN","APR","JUL","OCT"],"limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"006","parameter":"LC50 Static 48Hr Acute Cyprinodon variegatus","parameter_code":"TAA6A","statistic":"daily minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":["FEB","MAR","MAY","JUN","AUG","SEP","NOV","DEC"],"limit_set":"Unit  2 & 3 floor drains, surface runoff and yard drains.."},{"outfall":"007","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"007","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"008","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"008","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"009","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"009","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"012","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"012","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"014","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"014","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"015","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"015","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"016","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"016","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"017A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"Marine biology laboratory filter backwash."},{"outfall":"017A","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Marine biology laboratory filter backwash."},{"outfall":"017A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"Marine biology laboratory filter backwash."},{"outfall":"017A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"Marine biology laboratory filter backwash."},{"outfall":"019","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"019","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"021","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"021","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"022","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"022","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"024","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"024","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"024A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"024A","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"027","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"027","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"028","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"028","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"032","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["JAN"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."},{"outfall":"032","parameter":"Chlorine, total residual","parameter_code":"50060","statistic":"instantaneous maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":["FEB","MAR","APR","MAY","JUN","JUL","AUG","SEP","OCT","NOV","DEC"],"limit_set":"See table FW - fire water system flow test to Niantic Bay."}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"CT","sic":"4911"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=CT&sic=4911","url":"https://passage-data.com/api/v1/permits?state=CT&sic=4911","page":"https://passage-data.com/dmr/s/CT/4911"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"CT0003263"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=CT0003263"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"CT0003263"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=CT0003263"}]}