{"permit":"AR0052582","name":"Big River Steel LLC","state":"AR","as_of":"2026-10-22","source":{"publisher":"U.S. EPA — ECHO / ICIS-NPDES national file","as_of":"2026-10-22","page":"/dmr/p/AR0052582"},"about":[{"label":"What it is","text":"Blast Furnaces And Steel Mills (EPA's industry listing) · rated a major discharger by EPA"},{"label":"Where","text":"Osceola, Arkansas","href":"https://www.openstreetmap.org/?mlat=35.654000&mlon=-89.954389#map=14/35.654000/-89.954389"},{"label":"Last 12 months","text":"No values over a limit"},{"label":"Permit","text":"In force until Nov 30, 2026"}],"renewal_due":{"date":"2026-06-03","when":"Jun 3, 2026, overdue","urgent":true},"renewal_check":{"offered_because":"application_overdue","application_due":"2026-06-03","price":"free while piloted","order_page":"https://passage-data.com/dmr/p/AR0052582#renewal","says":"Each limit a renewal could tighten or add, from the state's water-quality standards and the federal rules for this kind of discharge, each cited to its rule, beside EPA's 12-month record; a rule we do not hold is named, never guessed. A person orders it on the permit's page with their email; it is sent by email within 5 business days."},"sector":{"state":"AR","sic":"33","permits":10,"list":"https://passage-data.com/api/v1/permits?state=AR&sic=33","page":"https://passage-data.com/dmr/s/AR/33"},"limits_from_version":null,"record":{"last_filed":"2026-09-30","over":0,"over_by":[],"window":["2025-10-01","2026-09-30"]},"over_limits":[],"limits":[{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":null,"value":null,"unit":"mg/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"766.6","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"725.1","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"1938.4","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"1828","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"104.3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"156.4","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"monthly average","qualifier":"<=","value":".67","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Iron, total recoverable","parameter_code":"00980","statistic":"daily maximum","qualifier":"<=","value":"1.4","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":"<=","value":".2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"monthly average","qualifier":"<=","value":".13","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, hexavalent [as Cr]","parameter_code":"01032","statistic":"daily maximum","qualifier":"<=","value":".4","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"monthly average","qualifier":"<=","value":".3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"monthly average","qualifier":"<=","value":".28","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":"<=","value":".8","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Nickel, total recoverable","parameter_code":"01074","statistic":"daily maximum","qualifier":"<=","value":".84","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":"<=","value":"3.2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"monthly average","qualifier":"<=","value":"3.3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":"<=","value":"9.8","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Zinc, total recoverable","parameter_code":"01094","statistic":"daily maximum","qualifier":"<=","value":"9.6","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"monthly average","qualifier":"<=","value":"2.3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"monthly average","qualifier":"<=","value":"2","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":"<=","value":"7","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Lead, total recoverable","parameter_code":"01114","statistic":"daily maximum","qualifier":"<=","value":"6","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"monthly average","qualifier":"<=","value":".4","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"monthly average","qualifier":"<=","value":".54","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"daily maximum","qualifier":"<=","value":".9","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Chromium, total recoverable","parameter_code":"01118","statistic":"daily maximum","qualifier":"<=","value":"1.3","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"monthly average","qualifier":"<=","value":".74","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Copper, total recoverable","parameter_code":"01119","statistic":"daily maximum","qualifier":"<=","value":"1.5","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"monthly average","qualifier":"<=","value":".07","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"monthly average","qualifier":"<=","value":".071","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"daily maximum","qualifier":"<=","value":".1","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Tetrachloroethylene","parameter_code":"34475","statistic":"daily maximum","qualifier":"<=","value":".14","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"monthly average","qualifier":"<=","value":".05","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"monthly average","qualifier":"<=","value":".047","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"daily maximum","qualifier":"<=","value":".09","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Naphthalene","parameter_code":"34696","statistic":"daily maximum","qualifier":"<=","value":".094","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Monthly Treated Process WW"},{"outfall":"001","parameter":"Cyanide, total recoverable","parameter_code":"78248","statistic":"monthly average","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Yearly Cyanide Reporting"},{"outfall":"001","parameter":"Cyanide, total recoverable","parameter_code":"78248","statistic":"daily maximum","qualifier":null,"value":null,"unit":"ug/L","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Yearly Cyanide Reporting"},{"outfall":"001","parameter":"Cyanide, total recoverable","parameter_code":"78248","statistic":"monthly average","qualifier":"<=","value":".081","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Yearly Cyanide Reporting"},{"outfall":"001","parameter":"Cyanide, total recoverable","parameter_code":"78248","statistic":"daily maximum","qualifier":"<=","value":".21","unit":"lb/d","report_only":false,"enforceable":true,"months":"all","limit_set":"001-Yearly Cyanide Reporting"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"minimum","qualifier":">=","value":"6","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"002-Monthly-Stormwater & Runoff From Slag Yard"},{"outfall":"002","parameter":"pH","parameter_code":"00400","statistic":"maximum","qualifier":"<=","value":"9","unit":"SU","report_only":false,"enforceable":true,"months":"all","limit_set":"002-Monthly-Stormwater & Runoff From Slag Yard"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"monthly average","qualifier":"<=","value":"100","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"002-Quarterly-Stormwater & Runoff From Slag Yard"},{"outfall":"002","parameter":"Solids, total suspended","parameter_code":"00530","statistic":"daily maximum","qualifier":"<=","value":"150","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"002-Quarterly-Stormwater & Runoff From Slag Yard"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"monthly average","qualifier":"<=","value":"10","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"002-Quarterly-Stormwater & Runoff From Slag Yard"},{"outfall":"002","parameter":"Oil & Grease","parameter_code":"00556","statistic":"daily maximum","qualifier":"<=","value":"15","unit":"mg/L","report_only":false,"enforceable":true,"months":"all","limit_set":"002-Quarterly-Stormwater & Runoff From Slag Yard"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"monthly average","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"002-Monthly-Stormwater & Runoff From Slag Yard"},{"outfall":"002","parameter":"Flow, in conduit or thru treatment plant","parameter_code":"50050","statistic":"daily maximum","qualifier":null,"value":null,"unit":"MGD","report_only":true,"enforceable":true,"months":"all","limit_set":"002-Monthly-Stormwater & Runoff From Slag Yard"},{"outfall":"TX1","parameter":"Whole effluent toxicity - retest #1","parameter_code":"22415","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"Whole effluent toxicity - retest #2","parameter_code":"22416","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"WET, sublethal retest #1","parameter_code":"22418","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"WET, sublethal retest #2","parameter_code":"22419","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"Whole Effluent Toxicity - Retest #3","parameter_code":"51443","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"Whole Effluent Toxicity, Sub-Lethal Retest #3","parameter_code":"51444","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex","parameter_code":"TEM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TEM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"pass=0;fail=1","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex","parameter_code":"TOM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas","parameter_code":"TOM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"Coef Of Var Static Renewal 48Hr Acute D. pulex","parameter_code":"TQM3D","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"},{"outfall":"TX1","parameter":"Coef Of Var Static Renewal 48Hr Acute Pimephales promelas","parameter_code":"TQM6C","statistic":"48-hour minimum","qualifier":null,"value":null,"unit":"%","report_only":true,"enforceable":true,"months":"all","limit_set":"001-Quarterly Acute WET Testing"}],"next":[{"tool":"list_permits","says":"Screening this industry? list_permits lists every permit of it in this state in one call, each with its page and its get_permit address; `get` is the address to fetch.","arguments":{"state":"AR","sic":"33"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=AR&sic=33","url":"https://passage-data.com/api/v1/permits?state=AR&sic=33","page":"https://passage-data.com/dmr/s/AR/33"},{"tool":"check_dmr","says":"Before your user files this permit's DMR: check_dmr sets each value beside the permit's limit for that period, with EPA's violation rule's verdict.","arguments":{"permit":"AR0052582"},"needs":{"period_end":"The reporting period: its month (2026-09).","values":"The period's values as your user will file them: [{outfall, parameter, statistic, value, unit}, ...]."},"post":"/api/v1/dmr/check","url":"https://passage-data.com/api/v1/dmr/check","page":"https://passage-data.com/dmr/?permit=AR0052582"},{"tool":"fill_dmr","says":"Has your user the plant's raw daily results? fill_dmr computes the period's DMR values from them, each with the rows it came from.","arguments":{"permit":"AR0052582"},"needs":{"period_end":"The reporting period: its month (2026-09).","rows":"The plant's results: [{date, parameter, value, unit, point}, ...]; or `table`, the lab's or plant's export as text."},"post":"/api/v1/dmr/fill","url":"https://passage-data.com/api/v1/dmr/fill","page":"https://passage-data.com/dmr/?permit=AR0052582"}]}