{"query":{"parameter":"zinc","place":"US-TX","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-TX","US"],"parameter_keys":["cas:7440-66-6","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc","name:iron, nickel (h), zinc","name:total zinc","name:total zinc (freshwater","name:zinc-65","cas:7646-85-7","cas:557-21-1","name:zinc extractible","cas:1314-84-7","name:zinc - total","name:zinc, total"],"names_matched":[["zinc","cas:7440-66-6"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["cadmium h copper h mercury lead h zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["cadmium h copper h mercury lead h zinc h","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["chemical oxygen demand arsenic radium dissolved and total uranium zinc","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc"],["chemical oxygen demand arsenic radium dissolved and total uranium zinc h","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc"],["iron nickel h zinc","name:iron, nickel (h), zinc"],["iron nickel h zinc h","name:iron, nickel (h), zinc"],["total zinc","name:total zinc"],["total zinc","name:total zinc (freshwater"],["total zinc freshwater","name:total zinc"],["total zinc freshwater","name:total zinc (freshwater"],["total zinc marine","name:total zinc"],["total zinc marine","name:total zinc (freshwater"],["zinc 65","name:zinc-65"],["zinc chloride","cas:7646-85-7"],["zinc cyanide","cas:557-21-1"],["zinc cyanide zn cn 2","cas:557-21-1"],["zinc extractible","name:zinc extractible"],["zinc phosphide","cas:1314-84-7"],["zinc phosphide when present at concentrations 10","cas:1314-84-7"],["zinc phosphide zn3 p2","cas:1314-84-7"],["zinc phosphide zn3p2","cas:1314-84-7"],["zinc total","name:zinc - total"],["zinc total","name:zinc, total"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":3401,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"3ce306d4fb411ded","parameter":"Zinc","value":"9.9E+03","value_num":9900,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, TotSoilComb, 0.5 acre source area","page":22,"quote":"Zinc 7440-66-6 9.9E+03 I n I 2.4E+03 I n >S 2.4E+05 I n >S ─ I ─ ─ I ─ 1.6E+03 9.9E+03 I n I 1.2E+03 I n >S I 1.2E+05 I n >S ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"6411ee466cbd66a0","parameter":"Zinc","value":"2.4E+03","value_num":2400,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoilIng, 0.5 acre source area","page":22,"quote":"Zinc 7440-66-6 9.9E+03 I n I 2.4E+03 I n >S 2.4E+05 I n >S ─ I ─ ─ I ─ 1.6E+03 9.9E+03 I n I 1.2E+03 I n >S I 1.2E+05 I n >S ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"92ef3c5e28390a70","parameter":"Zinc","value":"2.4E+05","value_num":240000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 0.5 acre source area","page":22,"quote":"Zinc 7440-66-6 9.9E+03 I n I 2.4E+03 I n >S 2.4E+05 I n >S ─ I ─ ─ I ─ 1.6E+03 9.9E+03 I n I 1.2E+03 I n >S I 1.2E+05 I n >S ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"a30a131d0cdb5439","parameter":"Zinc","value":"1.6E+03","value_num":1600,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoil for Secondary MCL, 0.5 acre source area","page":22,"quote":"Zinc 7440-66-6 9.9E+03 I n I 2.4E+03 I n >S 2.4E+05 I n >S ─ I ─ ─ I ─ 1.6E+03 9.9E+03 I n I 1.2E+03 I n >S I 1.2E+05 I n >S ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"c1bb70e9fd5c38d8","parameter":"Zinc","value":"9.9E+03","value_num":9900,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, TotSoilComb, 30 acre source area","page":22,"quote":"Zinc 7440-66-6 9.9E+03 I n I 2.4E+03 I n >S 2.4E+05 I n >S ─ I ─ ─ I ─ 1.6E+03 9.9E+03 I n I 1.2E+03 I n >S I 1.2E+05 I n >S ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"4fae159c2be0cad0","parameter":"Zinc","value":"1.2E+03","value_num":1200,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoilIng, 30 acre source area","page":22,"quote":"Zinc 7440-66-6 9.9E+03 I n I 2.4E+03 I n >S 2.4E+05 I n >S ─ I ─ ─ I ─ 1.6E+03 9.9E+03 I n I 1.2E+03 I n >S I 1.2E+05 I n >S ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"9ab8d89aa58888c6","parameter":"Zinc","value":"1.2E+05","value_num":120000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 30 acre source area","page":22,"quote":"Zinc 7440-66-6 9.9E+03 I n I 2.4E+03 I n >S 2.4E+05 I n >S ─ I ─ ─ I ─ 1.6E+03 9.9E+03 I n I 1.2E+03 I n >S I 1.2E+05 I n >S ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"fb1a46af1ddfaeb6","parameter":"Zinc","value":"8.0E+02","value_num":800,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoil for Secondary MCL, 30 acre source area","page":22,"quote":"Zinc 7440-66-6 9.9E+03 I n I 2.4E+03 I n >S 2.4E+05 I n >S ─ I ─ ─ I ─ 1.6E+03 9.9E+03 I n I 1.2E+03 I n >S I 1.2E+05 I n >S ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"8868c93c5e793b50","parameter":"Zinc","value":"2.5E+05","value_num":250000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 0.5 acre source area","page":37,"quote":"Zinc 7440-66-6 2.5E+05 n I 7.0E+03 I n >S I 7.0E+05 I n >S I ─ I ─ I ─ I ─ I 1.6E+03 2.5E+05 n I 3.5E+03 I n >S I 3.5E+05 I n >S I ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"0bf01e518bd83e0b","parameter":"Zinc","value":"7.0E+03","value_num":7000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 0.5 acre source area","page":37,"quote":"Zinc 7440-66-6 2.5E+05 n I 7.0E+03 I n >S I 7.0E+05 I n >S I ─ I ─ I ─ I ─ I 1.6E+03 2.5E+05 n I 3.5E+03 I n >S I 3.5E+05 I n >S I ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"0a36c408052ea751","parameter":"Zinc","value":"7.0E+05","value_num":700000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 0.5 acre source area","page":37,"quote":"Zinc 7440-66-6 2.5E+05 n I 7.0E+03 I n >S I 7.0E+05 I n >S I ─ I ─ I ─ I ─ I 1.6E+03 2.5E+05 n I 3.5E+03 I n >S I 3.5E+05 I n >S I ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"355c1dcd150b5f01","parameter":"Zinc","value":"1.6E+03","value_num":1600,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoil for Secondary MCL, 0.5 acre source area","page":37,"quote":"Zinc 7440-66-6 2.5E+05 n I 7.0E+03 I n >S I 7.0E+05 I n >S I ─ I ─ I ─ I ─ I 1.6E+03 2.5E+05 n I 3.5E+03 I n >S I 3.5E+05 I n >S I ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"c947515c9f37f78b","parameter":"Zinc","value":"2.5E+05","value_num":250000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 30 acre source area","page":37,"quote":"Zinc 7440-66-6 2.5E+05 n I 7.0E+03 I n >S I 7.0E+05 I n >S I ─ I ─ I ─ I ─ I 1.6E+03 2.5E+05 n I 3.5E+03 I n >S I 3.5E+05 I n >S I ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"2764bf1d3058b20f","parameter":"Zinc","value":"3.5E+03","value_num":3500,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 30 acre source area","page":37,"quote":"Zinc 7440-66-6 2.5E+05 n I 7.0E+03 I n >S I 7.0E+05 I n >S I ─ I ─ I ─ I ─ I 1.6E+03 2.5E+05 n I 3.5E+03 I n >S I 3.5E+05 I n >S I ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"38bbcde3b50f97bb","parameter":"Zinc","value":"3.5E+05","value_num":350000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 30 acre source area","page":37,"quote":"Zinc 7440-66-6 2.5E+05 n I 7.0E+03 I n >S I 7.0E+05 I n >S I ─ I ─ I ─ I ─ I 1.6E+03 2.5E+05 n I 3.5E+03 I n >S I 3.5E+05 I n >S I ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"a4ec0d7c3ca86aa7","parameter":"Zinc","value":"8.0E+02","value_num":800,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoil for Secondary MCL, 30 acre source area","page":37,"quote":"Zinc 7440-66-6 2.5E+05 n I 7.0E+03 I n >S I 7.0E+05 I n >S I ─ I ─ I ─ I ─ I 1.6E+03 2.5E+05 n I 3.5E+03 I n >S I 3.5E+05 I n >S I ─ I ─ I ─ I ─ 8.0E+02"}},{"id":"6b4ce6224ed13da1","parameter":"Zinc","value":"7.3E+00","value_num":7.3,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, GWGWIng, Residential","page":50,"quote":"Zinc 7440-66-6 7.3E+00 I n >S 7.3E+02 I n >S ─ I ─ ─ ─ 2.2E+01 I n >S 2.2E+03 I n >S ─ I ─ ─ ─ 5.0E+00"}},{"id":"873d5ecb74b64ccc","parameter":"Zinc","value":"7.3E+02","value_num":730,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, GWGWClass3, Residential","page":50,"quote":"Zinc 7440-66-6 7.3E+00 I n >S 7.3E+02 I n >S ─ I ─ ─ ─ 2.2E+01 I n >S 2.2E+03 I n >S ─ I ─ ─ ─ 5.0E+00"}},{"id":"d6ca637485026785","parameter":"Zinc","value":"2.2E+01","value_num":22,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, GWGWIng, Commercial/Industrial","page":50,"quote":"Zinc 7440-66-6 7.3E+00 I n >S 7.3E+02 I n >S ─ I ─ ─ ─ 2.2E+01 I n >S 2.2E+03 I n >S ─ I ─ ─ ─ 5.0E+00"}},{"id":"4ba52740dc7f6302","parameter":"Zinc","value":"2.2E+03","value_num":2200,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, GWGWClass3, Commercial/Industrial","page":50,"quote":"Zinc 7440-66-6 7.3E+00 I n >S 7.3E+02 I n >S ─ I ─ ─ ─ 2.2E+01 I n >S 2.2E+03 I n >S ─ I ─ ─ ─ 5.0E+00"}},{"id":"6e3b0a7c50947971","parameter":"Zinc","value":"5.0E+00","value_num":5,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria."],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, Secondary MCL","page":50,"quote":"Zinc 7440-66-6 7.3E+00 I n >S 7.3E+02 I n >S ─ I ─ ─ ─ 2.2E+01 I n >S 2.2E+03 I n >S ─ I ─ ─ ─ 5.0E+00"}},{"id":"849e0d0972a342bc","parameter":"Zinc","value":"0.978we(0.8473(ln(hardness))+0.884)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["receiving_water is freshwater","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))","hardness-dependent: the cell's equation of the receiving water's hardness (mg/L as input)"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(c) Table 1","page":40,"quote":null}},{"id":"5f0f97163957842a","parameter":"Zinc","value":"0.986we(0.8473(ln(hardness))+0.884)","unit":"µg/L","statistic":"weekly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["receiving_water is freshwater","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))","hardness-dependent: the cell's equation of the receiving water's hardness (mg/L as input)"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(c) Table 1","page":40,"quote":null}},{"id":"5eb9848e0b93bffe","parameter":"Zinc","value":"92.7w","value_num":92.7,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["receiving_water is marine","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(c) Table 1","page":40,"quote":null}},{"id":"a062d8210fbf589e","parameter":"Zinc","value":"84.2w","value_num":84.2,"unit":"µg/L","statistic":"weekly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-TX"],"conditions":["receiving_water is marine","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(c) Table 1","page":40,"quote":null}},{"id":"bec06248dc6ab604","parameter":"Zinc","value":"2.61","value_num":2.61,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Zinc 5 7440-66-6 2.61 4.3 mg/l TCLP"}},{"id":"982979ccdcdac148","parameter":"Zinc","value":"4.3 mg/l TCLP","value_num":4.3,"unit":"mg/L TCLP","statistic":"instant","direction":"max","kind":"limit","medium":"leachate","level":"national","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard","page":null,"quote":"Zinc 5 7440-66-6 2.61 4.3 mg/l TCLP"}},{"id":"7c6e90aba6823798","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"d89a5efb441081c6","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"55ee0122bcab26f3","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"a9be587fa686b4ac","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"7e3da0107714921c","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"b7224f12c2800dc8","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"dfc8eb8674ee1cd6","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"e78def7dd5987a01","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"3e3010b05bbf4001","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"00a3e1412e05b36c","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"4a6561c92dd7c189","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"48537d32365bd3d5","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"2dd736f1a8139689","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"6c9aabb9fa0dc2ce","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"96d2fe7eb89dbf21","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"7257a8701af5c2b9","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"e6868b2fdfafdc95","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"57e02ee1102080a1","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"d4f4bdc26e4ce779","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"51d41c9bfd242310","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"06441fc0bb33096b","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"a2cc63d4a1cd810e","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"8f6facb36bb719cb","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Zn 164 102"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-TX"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"zinc\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-TX"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}